| 
							
								| 
	
		|  |  
		| 
				
					
	
		| 
				
			 | 
				Fluke Networks DSX2-8000QI
                
                
                
 			 
				Catalog #: 4954622
Versiv 2 CableAnalyzer w/Quad OLTS and Fiber Inspection, Integrated Wi-Fi
 
 
                
                    OverviewSpecificationsAccessories 	
                    
				        
                        Product Highlights
    Kit includes the DSX2-8000 cable analyzer with      integrated WiFi functionality, CertiFiber Pro Quad OLTS model, and USB      video Inspection cameraCapable of testing and certifying twisted pair Cat 5e,      6, 6A, 8 and Class I/II cabling with limits up to 2 GHzHas a level VI/2G accuracy (2 GHz)Versiv 2 enables users to accomplish more than ever      with a cable tester, by accelerating every step of the testing processLinkWare Live cloud service lets the Project Manager      remotely set up the testers, monitor job progress and even locate tester      from any smart deviceProjX management system eases tasks from initial set-up      of a job to system acceptance. It eliminates redundant steps, and ensures      that all tests are completed correctly the first time, and every timeTaptive user interface puts advanced data analysis and      easy set-up and operation at the fingertips of technicians of all skill      levelsLinkWare PC management software provides unmatched      analysis of test results and professional test reportsThe DSX2-8000 reduces the time required to fix cabling      faults with dedicated diagnostics, a simple test that locates the problem Performance: 
    Eight second Cat 6A test time contributes to the      fastest way to gain certificationGraphically displays the source of failures including      crosstalk and distance to shield faults for faster troubleshootingManage up to 12,000 Cat 6A test results with full      graphicsCapacitive touchscreen allows quick tester setup with      easily selectable cable types, standards and testing parametersOver 1 billion links reported on LinkWare PC management      software Standards: 
    Compliant with ANSI/TIA-1152-A Level 2G and proposed      standard IEC 61935-1 Ed. 5 Level VI field tester accuracy requirements to      2000 MHzSupports the complete suite of Resistance Unbalance      standards needed for Power over Ethernet (PoE) - IEEE 802.3bt,      ANSI/TIA/EIA-568, ISO/IEC 11801 series documentsTCL and ELTCTL measurements compliant to IEC 61935-1-1      (Draft)Screen continuity along path of cabling Each Unit Includes
    1 - Versiv 2 Mainframe and Remote Unit2 - DSX-8000 CableAnalyzer Modules2 - CertiFiber Quad OLTS Modules1 - Set of Cat 8/Class I Permanent Link Adapters1 - Set of Cat 8/Class I Channel Adapters2 - Headsets2 - Handstraps2 - Shoulder Straps1 - Carry Case1 - USB Interface Cable1 - Versiv 2 Open Source Software CD2 - AC Chargers2 - Universal Couplers2 - AxTalk Terminators1 - USB Video Inspection Probe w/ 4 Tips2 - Quick Clean Cleaners (1.25/2.50 mm)2 - LC/LC Simplex Adapters1 - SC/LC EF-Compliant MM TRC Kit 50 µm1 - SC/LC SM TRC Kit1 - TRC Carry Case1 - WiFi Adapter for Versiv 2 Mainframe1 - Statement of Calibration1 - Start Guide 
                          
    
        
            | Category 8 test modes (or lower link categories) | ANSI/TIA-1152 Level 2G |  
            | Class I/II test modes | Proposed standard IEC 61935-1 Ed. 5 Level VI |  
            | Length of Twisted Pair Cabling1 |  
            |  | Without Remote | With Remote |  
            | Range | 800 m (2600 ft) | 150 m (490 ft) |  
            | Resolution | 0.1 m or 1 ft | 0.1 m or 1 ft |  
            | Accuracy | ± (0.3 m + 2 %); 0 m to 150 m ± (0.3 m + 4 %); 150 m to 800 m
 | ± (0.3 m + 2 %) |  
            | Propagation Delay |  
            |  | Without Remote | With Remote |  
            | Range | 4000 ns | 750 ns |  
            | Resolution | 1 ns | 1 ns |  
            | Accuracy | ± (2 ns + 2 %); 0 ns to 750 ns ± (2 ns + 4 %); 750 ns to 4000 ns
 | ± (2 ns + 2 %) |  
            | Delay Skew |  
            | Range | 0 ns to 100 ns |  
            | Resolution | 1 ns |  
            | Accuracy | ± 10 ns |  
            | DC Loop Resistance Test |  
            | Range | 0 Ω to 540 Ω |  
            | Resolution | 0.1 Ω |  
            | Accuracy | ± (1 Ω + 1 %) |  
            | Overload recovery time | Less than 10 minutes to rated accuracy following an overvoltage. Referencing is required after repeated or prolonged overvoltage. |    
    
        
            | Fluke Networks CertiFiber Pro Optical Loss Test Set Specifications |  
            | Power Meter Specifications |  
            | Input Connector | Interchangeable connector adapter (LC standard, SC, ST and FC optional) |  
            | Detector Type | InGaAs |  
            | Wavelengths | 850 nm, 1300 nm, 1310 nm, 1550 nm |  
            | Power Measurement Range | 0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths) |  
            | Power Measurement Uncertainty1,2 | < +/- 5% +/- 32 pW |  
            | Measurement Linearity3 | < ± 0.1 dB |  
            | Re-calibration Period | 1 year |  
            | 1. +/- 100 pW at 850 nm 2. Under the following conditions: Power level 100 μW (-10 dBm), continuous wave (CW) for absolute power at 850 nm and 1310 nm. Divergent beam, NA = 0.20 for 50/125 μm and NA = 0.14 for 9/125 μm. Ambient temperature 23° ± 1°C. SC/UPC connector with ceramic ferrule. After a 5 minute warm-up. Traceable to NIST.
 3. -3 dBm to -55 dBm at 850 nm and 1310 nm. Ambient temperature 23° ± 1°C. After a 5 minute warm-up.
 |  
            | Loss/Length Specifications |  
            | Specification | CertiFiber Pro Multimode Modules | CertiFiber Pro Singlemode Modules |  
            | Testing Speeds (excludes referencing times) | Smart Remote mode: < 3 seconds (2 wavelengths, one direction, auto wavelength detection) Far End Source mode: ≤ 2 seconds (2 wavelengths, one direction auto wavelength detection)
 Loopback mode: ≤ 2 seconds (2 wavelengths, one direction auto wavelength detection)
 |  
            | Input/Output Connectors | Interchangeable connector adapter (LC standard, SC, ST and FC optional) |  
            | Launch Condition1,2 | Encircled Flux compliant to TIA-526-14-B, ISO/IEC 14763-3 and IEC 61280-4-1 |  
            | Fiber Types Tested | 50/125 µm or 62.5/125 µm | singlemode |  
            | Source Type and Wavelengths | LED source 850 nm ± 30 nm 1300 nm ± 20 nm | Fabry-Perot laser diode 1310 nm ± 20 nm 1550 nm ± 30 nm |  
            | Maximum Length Measurement | 12 km | 130 km |  
            | Length Measurement Accuracy | ± 1.5 m plus ± 1 % of length | ± 1.5 m plus ± 1 % of length |  
            | Output Power (Nominal) | ≥ -24 dBm with EF-TRC | ≥ -4 dBm |  
            | Output Power Stability3 | ± 0.05 dB over 8 hours ± 0.03 dB over 15 minutes | ± 0.1 dB over 8 hours ± 0.08 dB over 15 minutes |  
            | 1. At the output of the EF-TRC 2. Variations between EF measurement equipment may occur but EF compliance can be expected with a 95% confidence factor
 3. Relative to power level after 15 minute warm up – at constant temperature
 |  
            | Loss/Length Specifications (continued) |  
            | Source Wavelengths | 850 nm, 1300 nm, 1310 nm, 1550 nm |  
            | Power Measurement Range | 0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths) |  
            | Power Measurement Uncertainty1, 2 | < +/- 5% +/- 32 pW |  
            | Measurement Linearity3 | < ± 0.1 dB |  
            | Re-calibration Period | 1 year |  
            | 1. +/- 100 pW at 850 nm 2. Under the following conditions: Power level 100 μW (-10 dBm), continuous wave (CW) for absolute power at 850
 |  
            | Selected Specifications |  
            | Visual Fault Locator (VFL) |  
            | Title | Requirement |  
            | Output Power | >-5 dBm <0 dBm
 SMF-28 singlemode fiber
 Continuous wave
 SC/UPC connector
 |  
            | Operating Wavelength | 650 nm nominal |  
            | Output Modes | Continuous wave Pulsed mode (2 Hz to 3 Hz blink frequency)
 |  
            | Connector Adapter | 2.5 mm universal |  
            | Laser Safety | Class II CDRH Over operating temperature range
 |  
            | Environmental Specifications |  
            | Title | Requirement |  
            | Operating Temperature | -18° C to 45° C |  
            | Storage Temperature | -30° C to +60° C |  
            | Operating Relative Humidity % RH without condensation
 | 0 % to 90 %, 32 °F to 95 °F (0° C to 35° C) 0 % to 70 %, 95 °F to 113 °F (35° C to 45° C)
 |  
            | Vibration | Random, 2 g, 5 Hz-500 Hz |  
            | Shock | 1 m drop test with and without module and adapters |  
            | Safety | CSA C22.2 No. 1010.1: 1992 EN 61010-1 1st Edition + Amendments 1, 2
 |  
            | Pollution Degree | 2 |  
            | Altitude | Operating: 4,000 m; storage: 12,000 m |  
            | EMC | EN 61326–1 |  |  
				 |  
     |  |