     1 - Versiv 2 Remote2 - DSX-8000 CableAnalyzer Modules1 - Set of Cat 8/Class I Permanent Link Adapters1 - Set of Cat 8/Class I Channel Adapters2 - Headsets2 - HandStraps2 - Shoulder Straps1 - Carry Case1 - Versiv 2 Open Source Software CD2 - AC Chargers2 - Universal Couplers2 - AxTalk Terminators1 - Statement of Calibration and Getting Started Guide  
                          
    
        
            | Performance Specifications |  
            | Category 8 test modes (or lower link categories) | ANSI/TIA-1152 Level 2G |  
            | Class I/II test modes | Proposed standard IEC 61935-1 Ed. 5 Level VI |  
            | Length of Twisted Pair Cabling1 |  
            |  | Without Remote | With Remote |  
            | Range | 800 m (2600 ft) | 150 m (490 ft) |  
            | Resolution | 0.1 m or 1 ft | 0.1 m or 1 ft |  
            | Accuracy | ± (0.3 m + 2 %); 0 m to 150 m ± (0.3 m + 4 %); 150 m to 800 m
 | ± (0.3 m + 2 %) |  
            | Propagation Delay |  
            |  | Without Remote | With Remote |  
            | Range | 4000 ns | 750 ns |  
            | Resolution | 1 ns | 1 ns |  
            | Accuracy | ± (2 ns + 2 %); 0 ns to 750 ns ± (2 ns + 4 %); 750 ns to 4000 ns
 | ± (2 ns + 2 %) |  
            | Delay Skew |  
            | Range | 0 ns to 100 ns |  
            | Resolution | 1 ns |  
            | Accuracy | ± 10 ns |  
            | DC Loop Resistance Test |  
            | Range | 0 Ω to 540 Ω |  
            | Resolution | 0.1 Ω |  
            | Accuracy | ± (1 Ω + 1 %) |  