				Fluke Networks DSX2-8000
                
                
                
 			 
				Catalog #: 4954464
2 GHz DSX Cable Analyzer V2, with Wi-Fi
 
 
                
                    OverviewSpecificationsAccessories 	
                    
				        
                        Product Highlights
    DSX2-8000 comes with integrated WiFi functionality for      connecting wirelessly with Fluke Network's LinkWare Live
Capable of testing and certifying twisted pair Cat 5e,      6, 6A, 8 and Class I/II cabling with limits up to 2 GHz
Has a level VI/2G accuracy (2 GHz)
Versiv 2 enables users to accomplish more than ever      with a cable tester, by accelerating every step of the testing process
LinkWare Live cloud service lets the Project Manager      remotely set up the testers, monitor job progress and even locate tester      from any smart device
ProjX management system eases tasks from initial set-up      of a job to system acceptance. It eliminates redundant steps, and ensures      that all tests are completed correctly the first time, and every time
Taptive user interface puts advanced data analysis and      easy set-up and operation at the fingertips of technicians of all skill      levels
LinkWare PC management software provides unmatched      analysis of test results and professional test reports
The DSX reduces the time required to fix cabling faults      with dedicated diagnostics, a simple test that locates the problem
 Performance: 
    Eight second Cat 6A test time contributes to the      fastest way to gain certification
Graphically displays the source of failures including      crosstalk and distance to shield faults for faster troubleshooting
Manage up to 12,000 Cat 6A test results with full      graphics
Capacitive touchscreen allows quick tester setup with      easily selectable cable types, standards and testing parameters
Over 1 billion links reported on LinkWare PC management      software
 Standards: 
    Compliant with ANSI/TIA-1152-A Level 2G and proposed      standard IEC 61935-1 Ed. 5 Level VI field tester accuracy requirements to      2000 MHz
Supports the complete suite of Resistance Unbalance      standards needed for Power over Ethernet (PoE) - IEEE 802.3bt,      ANSI/TIA/EIA-568, ISO/IEC 11801 series documents
TCL and ELTCTL measurements compliant to IEC 61935-1-1      (Draft)
Screen continuity along path of cabling Each Unit Includes
    1 - Versiv 2 Mainframe & Remote2 - DSX-8000 CableAnalyzer modules1 - Set of Cat 8/Class I Permanent Link Adapters1 - Set of Cat 8/Class I Channel Adapters2 - Headsets2 - HandStrap2 - Shoulder Straps1 - Carry case with shoulder strap1 - USB interface cable1 - Versiv 2 Open Source Software CD2 - AC Chargers2 - Universal Couplers2 - AxTalk Terminators1 - Wifi adapter1 - Statement of Calibration1 - Start Guide 
                          
    
        
            | Performance Specifications |  
            | Category 8 test modes (or lower link categories) | ANSI/TIA-1152 Level 2G |  
            | Class I/II test modes | Proposed standard IEC 61935-1 Ed. 5 Level VI |  
            | Length of Twisted Pair Cabling1 |  
            |  | Without Remote | With Remote |  
            | Range | 800 m (2600 ft) | 150 m (490 ft) |  
            | Resolution | 0.1 m or 1 ft | 0.1 m or 1 ft |  
            | Accuracy | ± (0.3 m + 2 %); 0 m to 150 m ± (0.3 m + 4 %); 150 m to 800 m
 | ± (0.3 m + 2 %) |  
            | Propagation Delay |  
            |  | Without Remote | With Remote |  
            | Range | 4000 ns | 750 ns |  
            | Resolution | 1 ns | 1 ns |  
            | Accuracy | ± (2 ns + 2 %); 0 ns to 750 ns ± (2 ns + 4 %); 750 ns to 4000 ns
 | ± (2 ns + 2 %) |  
            | Delay Skew |  
            | Range | 0 ns to 100 ns |  
            | Resolution | 1 ns |  
            | Accuracy | ± 10 ns |  
            | DC Loop Resistance Test |  
            | Range | 0 Ω to 540 Ω |  
            | Resolution | 0.1 Ω |  
            | Accuracy | ± (1 Ω + 1 %) |  
            | Overload recovery time | Less than 10 minutes to rated accuracy following an overvoltage. Referencing is required after repeated or prolonged overvoltage. |  |  
				 |  
     |  |