				Fluke Calibration 9190A-A-156
                
                
                
 			 
				Catalog #: 4178780
Ultra-Cool Field Metrology Well, INSRT-A, 115V
 
 
                
                    OverviewSpecificationsSummarySoftwareCasesInsertsAccessories 	
                    
				        
                        Product HighlightsWide temperature range Excellent accuracy 
    Accuracy using built-in reference thermometer readout:  ± 0.05 °C full rangeDisplay accuracy:  ± 0.2 °C full range Best-in-class stability Fast cooling time 
    23 °C to –90 °C:  80 minutes23 °C to –95 °C:  90 minutes140 °C to 23 °C:  60 minutes Portability 
    Weighs only 16 kg (35 lbs)Built-in front and back handles for easy two-handed carry Best measurement practices 
    Conforms with EURAMET cg-13 guidance on measurement practices for temperature calibrators Ergonomics 
    Two-handed carry; built-in handles on front and backAll controls and inputs on the front panel Stability indicator 
    Shows whether block temperature is stable and within limits defined by the user PC interface 
    USB and RS-232 support remote operation from a computer Dual heater zone 
    Active heater zone control compensates for differential temperatures between zonesMinimizes axial temperature gradients Ramp-and-soak set-points 
    Define up to eight set-point temperatures; automatically ramp to and “soak” at each set-pointSpecify soak time, number of cycles, and direction Fast time to temperature and small footprint 
    Compact, efficient free piston Stirling cooler technology (FPSC) Each Unit Includes
    Report of Calibration with calibration label. Accredited ISO17025 Calibration 
                        
    
        
            | Base unit specifications |  
            | Temperature range at 23 °C | –95 °C to 140 °C (–139 °F to 284 °F) |  
            | Display  accuracy | ± 0.2 °C full range |  
            | Accuracy with  external reference [3] | ± 0.05 °C full range |  
            | Stability | ± 0.015 °C full range |  
            | Axial uniformity at 40 mm (1.6  in) | ± 0.05 °C full range |  
            | Radial gradient | ±0.01 °C full range |  
            | Loading effect | (with a 6.35  mm reference probe  and three  6.35  mm probes) |  
            | ± 0.006 °C full range |  
            | (versus display  with one 6.35  mm probe) |  
            | ± 0.25 °C at –95 °C |  
            | ± 0.10 °C at 140 °C |  
            | Operating conditions | 0 °C to 35 °C, 0 % to 90 % |  
            | RH (non-condensing) < 2000 m altitude |  
            | Environmental conditions for all specifications except temperature range | 13 °C to 33 °C |  
            | Immersion (well)  depth | 160  mm (6.3 in) |  
            | Well diameter | 30 mm (1.18 in) |  
            | Heating time [1] | –95 °C to 140 °C: 40 min |  
            | Cooling  time [1] | 23 °C to –90 °C: 80 min |  
            | 23 °C to –95 °C: 90 min |  
            | 140 °C to 23 °C: 60 min |  
            | Stabilization time [2] | 15 min |  
            | Resolution | 0.01  ° |  
            | Display | LCD, °C or °F user selectable |  
            | Size (H x W x D) | 480  mm x 205  mm x 380  mm (18.8 in x 8.0 in x 14.9  in) |  
            | Weight | 16 kg (35 lb) |  
            | Power requirements | 100 V to 115 V (± 10 %) 50/60 Hz, 575 W |  
            | 200 V to 230 V (± 10 %) 50/60 Hz, 575 W |  
            | System fuse  ratings | 115 V: 6.3 A T 250 V |  
            | 230 V: 3.15  A T 250 V |  
            | 4–20 mA Fuse  (-P model only) | 50 mA F 250 V |  
            | Computer interface | RS-232, USB Serial, and 9930 interface-it temperature calibration software included |  
            | Safety | IEC 61010-1, Installation Category II, Pollution degree 2 |  
            | Electromagnetic environment | IEC 61326-1: Basic |  
            | Refrigerants | R32 (Difluoromethane) |  
            | < 20 g, ASHRAE safety group A2L |  
            | R704 (Helium) |  
            | < 20 g, ASHRAE safety group A1 |    
    
        
            | -P Specifications |  
            | Built-in reference thermometer readout accuracy (4-wire reference probe) [3] | ± 0.010 °C at –95 °C |  
            | ± 0.013 °C at –25 °C |  
            | ± 0.015 °C at 0 °C |  
            | ± 0.020 °C at 50 °C |  
            | ± 0.025 °C at 140 °C |  
            | Reference resistance range | 0 Ω to 400 Ω |  
            | Reference resistance accuracy [4] | 0 Ω to 42 Ω: ± 0.0025 Ω 42 Ω to 400  Ω: ± 60 ppm of reading
 |  
            | Reference characterizations | ITS-90, CVD, IEC-751, resistance |  
            | Reference measurement capability | 4 wire |  
            | Reference probe connection | 6-pin din with INFO-CON technology |  
            | Built-in RTD thermometer readout accuracy | NI-120: ± 0.015 °C at 0 °C |  
            | PT-100 (385): ± 0.02 °C at 0 °C |  
            | PT-100 (3926):  ± 0.02 °C at 0 °C |  
            | PT-100 (JIS): ± 0.02 °C at 0 °C |  
            | RTD resistance range | 0 Ω to 400 Ω |  
            | Resistance accuracy [4] | 0 Ω to 25 Ω: ± 0.002 Ω |  
            | 25 Ω to 400 Ω: ± 80 ppm of reading |  
            | RTD characterizations | PT-100 (385), (JIS), (3926), NI-120, resistance |  
            | RTD measurement capability | 2-wire, 3-wire, and 4-wire RTD with jumpers  only |  
            | RTD connection | 4-terminal input |  
            | Built-in TC thermometer readout accuracy [5] | Type J: ± 0.70 °C at 140 °C |  
            | Type K: ± 0.75 °C at 140 °C |  
            | Type T: ± 0.60 °C at 140 °C |  
            | Type E: ± 0.60 °C at 140 °C |  
            | Type R: ± 1.60  °C at 140  °C |  
            | Type S: ± 1.60  °C at 140  °C |  
            | Type M: ± 0.65  °C at 140  °C |  
            | Type L: ± 0.65  °C at 140  °C |  
            | Type U: ± 0.70 °C at 140 °C |  
            | Type N: ± 0.75 °C at 140 °C |  
            | Type C: ± 1.00 °C at 140 °C |  
            | TC millivolt range | –10  mV to 75 mV |  
            | Voltage accuracy | 0.025 % of reading +0.01 mV |  
            | Internal cold  junction compensation accuracy | ± 0.35 °C (ambient of 13 °C to 33 °C) |  
            | TC connection | Miniature connectors (ASTM E1684) |  
            | Built-in mA readout accuracy | 0.02  % of reading + 0.002 mA |  
            | mA range | Cal 4-22 mA, Spec 4-24 mA |  
            | mA connection | 2 terminal  input |  
            | Loop power function | 24 V dc loop power |  
            | Built-in electronics temperature coefficient (0 °C to 13 °C, 33 °C to 50 °C)
 | ± 0.005 % of range  per °C |  Notes:[1]   For ambient temperature of 23 °C.
 [2]   Time from when the SETPOINT is reached to when the unit is with in stability  specification.
 [3]   The temperature range  may be limited by the reference probe  connected to the readout.
 The built-in reference accuracy  does not include  the sensor  probe  accuracy.  It does not include  the probe  uncertainty or probe  characterization errors.
 [4]   Measurement accuracy  specifications apply within  the operating range  and assume 4 wires  for PRTs. With 3-wire RTDs add 0.05  Ωto the measurement accuracy  plus the maximum possible  difference between the resistances of the lead wires.
 [5]   The thermocouple input readout is sensitive to EM fields in the frequency range  of 500  MHz to 700  MHz.
   
    
        
         
            | Calibration Included | Factory Calibration |  
            | Product Weight | 38 LBS |  
            | ECCN Number | EAR99 |  
            | Country of Origin | United States |  |  
					
                
        
        