				Fluke MDA-550-III
                
                
                
 			 
				Catalog #: 5282560
Motor Drive Analyzer 550, 4-channel color, PRO
 
 
                
                    OverviewSpecificationsCasesSoftwareProbesClamp MetersAccessories 	
                    
				        
                        Product Highlights 
    Motor Drive Analyzer, 4 Channel, 500 MHz with motor shaft and harmonicsGuided testing with graphical step-by-step voltage and current connection diagrams makes setup and connection to variable frequency drives easier than everPreset measurement profiles collect data based on the chosen test procedure and reduce the need for complex configurationBuilt-in report writing capabilities make it easy to produce professional as-found and as-left motor-drive troubleshooting reports Each Unit Includes 
    (1) BP 291 li-ion battery pack(1) BC190 charger/power adapter(3) VPS 100:1 high voltage probes with alligator clips(1) VPS410-II-R 10:1 500MHz voltage probe(3) i400s ac current clamp(1) C1740 carrying case(1) 2 GB USB drive with manuals and FlukeView™ 2 software(1) SVS-500 shaft voltage set (3x brush, probe holder, two-piece extension rod and magnetic base)(1) ISO 9001 - Statement of Calibration Practices  
                          
    
        
            | Measurement Function |  
            | DC voltage (V dc) |  
            | Maximum voltage with 10:1 or 100:1 probe | 1000 V |  
            | Maximum resolution with 10:1 or 100:1 probe | 1 mV |  
            | Full scale reading | 999 counts |  
            | Accuracy at 4 s to 10 us/div | ±(3 % + 6 counts) |  
            | AC voltage (V ac) |  
            | Maximum voltage with 10:1 or 100:1 probe | 1000 V |  
            | Maximum resolution with 10:1 or 100:1 probe | 1 mV |  
            | Full scale reading | 999 counts |  
            | 50 Hz | ±(3 % + 10 counts) - 0.6 % |  
            | 60 Hz | ±(3 % + 10 counts) - 0.4 % |  
            | 60 Hz to 20 kHz | ±(4 % + 15 counts) |  
            | 20 kHz to 1 MHz | ±(6 % + 20 counts) |  
            | 1 MHz to 25 MHz | ±(10 % + 20 counts) |  
            | True-rms voltage (V ac+dc) |  
            | Maximum voltage with 10:1 or 100:1 probe | 1000 V |  
            | Maximum resolution with 10:1 or 100:1 probe | 1 mV |  
            | Full scale reading | 1100 counts |  
            | DC to 60 Hz | ±(3 % + 10 counts) |  
            | 60 Hz to 20 kHz | ±(4 % + 15 counts) |  
            | 20 kHz to 1 MHz | ±(6 % + 20 counts) |  
            | 1 MHz to 25 MHz | ±(10 % + 20 counts) |  
            | PWM voltage (V pwm) |  
            | Purpose | To measure on pulse width modulated signals, like motor drive inverter outputs |  
            | Principle | Readings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency |  
            | Accuracy | As Vac+dc for sinewave signals |  
            | Peak voltage (V peak) |  
            | Modes | Max peak, min peak, or pk-to-pk |  
            | Maximum voltage with 10:1 or 100:1 probe | 1000 V |  
            | Maximum resolution with 10:1 or 100:1 probe | 10 mV |  
            | Accuracy |  
            | Max peak, min peak | ±0.2 division |  
            | Pk-to-pk | ±0.4 division |  
            | Full scale reading | 800 counts |    
    
        
            | General Specification |  
            | Current (AMP) with current clamp |  
            | Ranges | Same as V ac, Vac+dc or V peak |  
            | Scale Factors | 0.1 mV/A, 1 mV/A, 10 mV/A, 20 mV/A, 50mV/A, 100 mV/A, 200 mV/A, 400 mV/A |  
            | Accuracy | Same as Vac, Vac+dc or V peak (add current clamp accuracy) |  
            | Frequency (Hz) |  
            | Range | 1.000 Hz to 500 MHz |  
            | Full scale reading | 999 counts |  
            | Accuracy | ±(0.5 % + 2 counts) |  
            | Voltage/Herz ratio (V/Hz) |  
            | Purpose | To show the measured V PWM value (see V PWM) divided by the fundamental frequency on variable ac motor speed drives |  
            | Accuracy | % Vrms + % Hz |  
            | Voltage unbalance drive input |  
            | Purpose | To show the highest percentage difference of one of the phase vs average of the 3 true-rms voltages |  
            | Accuracy | Indicative percentage based on Vac+dc values |  
            | Voltage unbalance drive output and motor input |  
            | Purpose | To show the highest percentage difference of one of the phase vs average of the 3 PWM voltages |  
            | Accuracy | Indicative percentage based on V PWM values |  
            | Current unbalance drive input |  
            | Purpose | To show the highest percentage difference of one of the phase vs average of the 3 AC current values |  
            | Accuracy | Indicative percentage based on Aac+dc values |  
            | Current unbalance drive output and motor input |  
            | Purpose | To show the highest percentage difference of one of the phase vs average of the 3 AC current values |  
            | Accuracy | Indicative percentage based on A ac values |  
            | Rise and fall time |  
            | Readings | Voltage difference (dV), time difference (dt), voltage vs time difference (dV/dt), overshoot |  
            | Accuracy | As oscilloscope accuracy |  
            | Harmonics and spectrum |  
            | Harmonics | DC to 51st |  
            | Spectrum ranges | 1…9 kHz, 9-150 kHz (20 MHz filter on), up to 500 MHz (voltage modulation) |  
            | Shaft voltage |  
            | Events / second | Indicative percentage based on rise and fall time (Impulse discharges) measurements |  
            | Report data capture |  
            | Number of screens | Typical 50 screens can be saved in reports (depends on compression ratio) |  
            | Transfer to PC | Using 2 GB USB stick or mini-USB to USB cable and FlukeView™ 2 for ScopeMeter™ test tool |  
            | Probe settings |  
            | Voltage probe | 1:1, 10:1, 100:1, 1000:1, 20:1, 200:1 |  
            | Current clamp | 0.1 mV/A, 1 mV/A, 10 mV/A, 20 mV/A, 50 mV/A, 100 mV/A, 200 mV/A, 400 mV/A |  
            | Shaft voltage probe | 1:1, 10:1, 100:1 |  |  
					
                
        
        
              Cases
              Software
              Probes
            
            
                
                        
                            | Product | Price |  
                            |  | Fluke VPS410-II-R 
                                    Catalog #: 4276928
Industrial Voltage Probe Set 500MHZ 10:1 Red | $262.25
 
 |  
              Clamp Meters
            
            
                
                        
                            | Product | Price |  
                            |  | Fluke I400S 
                                    Catalog #: 2277202
Current Probe | $364.24
 
 |  
              Accessories
            
            
                
                        
                            | Product | Price |  
                            |  | Fluke BP291 
                                    Catalog #: 3894688
Li-Ion Double Capacity Battery Pack | $463.24
 
 |  
                            |  | Fluke SB-500 
                                    Catalog #: 5011046
Replacement brushes for SVS-500 and MDA-500 | $389.25
 
 |  
                            |  | Fluke SVS-500 
                                    Catalog #: 5011031
Shaft Voltage Set and Magnetic Base | $514.24
 
 |  
				 |  
     |  |