Fluke MDA-510
Catalog #: 4984691
Motor Drive Analyzer 510, 4-channel color
- Overview
- Specifications
- Cases
- Software
- Probes
- Clamp Meters
- Accessories
Product Highlights
- Guided testing with graphical step-by-step voltage and current connection diagrams makes setup and connection to variable frequency drives easier than ever
- Preset measurement profiles collect data based on the chosen test procedure and reduce the need for complex configuration
- Built-in report writing capabilities make it easy to produce professional as-found and as-left motor-drive troubleshooting reports
Each Unit Includes
- (1) BP 291 li-ion battery pack
- (1) BC190 charger/power adapter
- (3) VPS 100:1 high voltage probes with alligator clips
- (1) VPS410-II-R 10:1 500MHz voltage probe
- (1) i400s ac current clamp
- (1) C1740 carrying case
- (1) 2 GB USB drive with manuals and FlukeView™ 2 software
| Measurement Function |
| DC voltage (V dc) |
| Maximum voltage with 10:1 or 100:1 probe |
1000 V |
| Maximum resolution with 10:1 or 100:1 probe |
1 mV |
| Full scale reading |
999 counts |
| Accuracy at 4 s to 10 us/div |
±(3 % + 6 counts) |
| AC voltage (V ac) |
| Maximum voltage with 10:1 or 100:1 probe |
1000 V |
| Maximum resolution with 10:1 or 100:1 probe |
1 mV |
| Full scale reading |
999 counts |
| 50 Hz |
±(3 % + 10 counts) - 0.6 % |
| 60 Hz |
±(3 % + 10 counts) - 0.4 % |
| 60 Hz to 20 kHz |
±(4 % + 15 counts) |
| 20 kHz to 1 MHz |
±(6 % + 20 counts) |
| 1 MHz to 25 MHz |
±(10 % + 20 counts) |
| True-rms voltage (V ac+dc) |
| Maximum voltage with 10:1 or 100:1 probe |
1000 V |
| Maximum resolution with 10:1 or 100:1 probe |
1 mV |
| Full scale reading |
1100 counts |
| DC to 60 Hz |
±(3 % + 10 counts) |
| 60 Hz to 20 kHz |
±(4 % + 15 counts) |
| 20 kHz to 1 MHz |
±(6 % + 20 counts) |
| 1 MHz to 25 MHz |
±(10 % + 20 counts) |
| PWM voltage (V pwm) |
| Purpose |
To measure on pulse width modulated signals, like motor drive inverter outputs |
| Principle |
Readings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency |
| Accuracy |
As Vac+dc for sinewave signals |
| Peak voltage (V peak) |
| Modes |
Max peak, min peak, or pk-to-pk |
| Maximum voltage with 10:1 or 100:1 probe |
1000 V |
| Maximum resolution with 10:1 or 100:1 probe |
10 mV |
| Accuracy |
| Max peak, min peak |
±0.2 division |
| Pk-to-pk |
±0.4 division |
| Full scale reading |
800 counts |
| General Specification |
| Current (AMP) with current clamp |
| Ranges |
Same as V ac, Vac+dc or V peak |
| Scale Factors |
0.1 mV/A, 1 mV/A, 10 mV/A, 20 mV/A, 50mV/A, 100 mV/A, 200 mV/A, 400 mV/A |
| Accuracy |
Same as Vac, Vac+dc or V peak (add current clamp accuracy) |
| Frequency (Hz) |
| Range |
1.000 Hz to 500 MHz |
| Full scale reading |
999 counts |
| Accuracy |
±(0.5 % + 2 counts) |
| Voltage/Herz ratio (V/Hz) |
| Purpose |
To show the measured V PWM value (see V PWM) divided by the fundamental frequency on variable ac motor speed drives |
| Accuracy |
% Vrms + % Hz |
| Voltage unbalance drive input |
| Purpose |
To show the highest percentage difference of one of the phase vs average of the 3 true-rms voltages |
| Accuracy |
Indicative percentage based on Vac+dc values |
| Voltage unbalance drive output and motor input |
| Purpose |
To show the highest percentage difference of one of the phase vs average of the 3 PWM voltages |
| Accuracy |
Indicative percentage based on V PWM values |
| Current unbalance drive input |
| Purpose |
To show the highest percentage difference of one of the phase vs average of the 3 AC current values |
| Accuracy |
Indicative percentage based on Aac+dc values |
| Current unbalance drive output and motor input |
| Purpose |
To show the highest percentage difference of one of the phase vs average of the 3 AC current values |
| Accuracy |
Indicative percentage based on A ac values |
| Rise and fall time |
| Readings |
Voltage difference (dV), time difference (dt), voltage vs time difference (dV/dt), overshoot |
| Accuracy |
As oscilloscope accuracy |
| Harmonics and spectrum |
| Harmonics |
DC to 51st |
| Spectrum ranges |
1…9 kHz, 9-150 kHz (20 MHz filter on), up to 500 MHz (voltage modulation) |
| Shaft voltage |
| Events / second |
Indicative percentage based on rise and fall time (Impulse discharges) measurements |
| Report data capture |
| Number of screens |
Typical 50 screens can be saved in reports (depends on compression ratio) |
| Transfer to PC |
Using 2 GB USB stick or mini-USB to USB cable and FlukeView™ 2 for ScopeMeter™ test tool |
| Probe settings |
| Voltage probe |
1:1, 10:1, 100:1, 1000:1, 20:1, 200:1 |
| Current clamp |
0.1 mV/A, 1 mV/A, 10 mV/A, 20 mV/A, 50 mV/A, 100 mV/A, 200 mV/A, 400 mV/A |
| Shaft voltage probe |
1:1, 10:1, 100:1
|
|
Cases
Software
Probes
| Product |
Price |
 |
Fluke VPS410-II-R
Catalog #: 4276928
Industrial Voltage Probe Set 500MHZ 10:1 Red
|
$262.25
|
Clamp Meters
| Product |
Price |
 |
Fluke I400S
Catalog #: 2277202
Current Probe
|
$364.24
|
Accessories
| Product |
Price |
 |
Fluke BP291
Catalog #: 3894688
Li-Ion Double Capacity Battery Pack
|
$463.24
|
 |
Fluke SB-500
Catalog #: 5011046
Replacement brushes for SVS-500 and MDA-500
|
$389.25
|
 |
Fluke SVS-500
Catalog #: 5011031
Shaft Voltage Set and Magnetic Base
|
$514.24
|
|
|
|