| General Specification | 
        
            | Current (AMP) with current clamp | 
        
            | Ranges | Same as V ac, Vac+dc or V peak | 
        
            | Scale Factors | 0.1 mV/A, 1 mV/A, 10 mV/A, 20 mV/A, 50mV/A, 100 mV/A, 200 mV/A, 400 mV/A | 
        
            | Accuracy | Same as Vac, Vac+dc or V peak (add current clamp accuracy) | 
        
            | Frequency (Hz) | 
        
            | Range | 1.000 Hz to 500 MHz | 
        
            | Full scale reading | 999 counts | 
        
            | Accuracy | ±(0.5 % + 2 counts) | 
        
            | Voltage/Herz ratio (V/Hz) | 
        
            | Purpose | To show the measured V PWM value (see V PWM) divided by the fundamental frequency on variable ac motor speed drives | 
        
            | Accuracy | % Vrms + % Hz | 
        
            | Voltage unbalance drive input | 
        
            | Purpose | To show the highest percentage difference of one of the phase vs average of the 3 true-rms voltages | 
        
            | Accuracy | Indicative percentage based on Vac+dc values | 
        
            | Voltage unbalance drive output and motor input | 
        
            | Purpose | To show the highest percentage difference of one of the phase vs average of the 3 PWM voltages | 
        
            | Accuracy | Indicative percentage based on V PWM values | 
        
            | Current unbalance drive input | 
        
            | Purpose | To show the highest percentage difference of one of the phase vs average of the 3 AC current values | 
        
            | Accuracy | Indicative percentage based on Aac+dc values | 
        
            | Current unbalance drive output and motor input | 
        
            | Purpose | To show the highest percentage difference of one of the phase vs average of the 3 AC current values | 
        
            | Accuracy | Indicative percentage based on A ac values | 
        
            | Rise and fall time | 
        
            | Readings | Voltage difference (dV), time difference (dt), voltage vs time difference (dV/dt), overshoot | 
        
            | Accuracy | As oscilloscope accuracy | 
        
            | Harmonics and spectrum | 
        
            | Harmonics | DC to 51st | 
        
            | Spectrum ranges | 1…9 kHz, 9-150 kHz (20 MHz filter on), up to 500 MHz (voltage modulation) | 
        
            | Shaft voltage | 
        
            | Events / second | Indicative percentage based on rise and fall time (Impulse discharges) measurements | 
        
            | Report data capture | 
        
            | Number of screens | Typical 50 screens can be saved in reports (depends on compression ratio) | 
        
            | Transfer to PC | Using 2 GB USB stick or mini-USB to USB cable and FlukeView™ 2 for ScopeMeter™ test tool | 
        
            | Probe settings | 
        
            | Voltage probe | 1:1, 10:1, 100:1, 1000:1, 20:1, 200:1 | 
        
            | Current clamp | 0.1 mV/A, 1 mV/A, 10 mV/A, 20 mV/A, 50 mV/A, 100 mV/A, 200 mV/A, 400 mV/A | 
        
            | Shaft voltage probe | 1:1, 10:1, 100:1 
 |