				Megger MIT400/2
                
                
                
 			 
				Catalog #: 1004-731
600V CATIV Industrial Insulation and Continuity Tester 250V/500V/1000V
 
 
 
                
                    OverviewSpecificationsSummaryAccessories 	
                    
				        
                        Product Highlights 
    Designed for electrical and industrial TestingInsulation testing up to 1000VStabilized insulation test voltageSingle range, faster continuity testing600 V Trms AC and DC voltage measurementLive circuit detection and protectionUser variable insulation test voltage from 250V to 1000VCAT IV 600V and IP54 Each Unit Includes 
    1  x  MIT400/2 series instrument1  x  Hard carry case1  x  Red/black test lead set with clips6  x  AA (LR6) batteries fitted1  x  Warranty card1  x  Calibration certificate1  x  Owners CD manual1  x  Quick start guide 
                          
    
        
            | Megger MIT400/2 General Specifications |  
            | *All quoted accuracies are at +20° C. |  
            | Insulation Nominal test voltages | 250 V, 500 V, 1000 V |  
            | Insulation resistance range | 20 GΩ |  
            | Range Full Scale Accuracy | 1000 volts ±3% ±2 digits ±0.2% per GΩ 500 volts ±3% ±2 digits ±0.4% per GΩ
 250 volts ±3% ±2 digits ±0.8% per GΩ
 |  
            | Analog range | 1 GΩ full scale |  
            | Short Circuit Current | 2 mA +0% -50% |  
            | Terminal voltage | -0% +20% ±1 V |  
            | Test Current on load | 1 mA at min. pass value of insulation specified in BS7671, HD384and IEC364, 2 mA max. |  
            | EN61557 Operating range | 0.10 M½ to 1.00 GΩ |  
            | Leakage Current | 10% ±3 digits |  
            | Voltage display | 3% ±3 digits ±0.5% of rated voltage |  
            | Polarization Index (PI) | 10 min/1 minute ratio |  
            | Dielectric Absorption Ratio (DAR) | 60 sec/30 sec ratio |  
            | Notes | (1) All ranges measure from 0.00 M½ upwards. (2) Above specifications only apply when high quality silicone leadsare being used.
 |  
            | Continuity |  
            | Measurement | 0.01 ½ to 99.9 ½ (0 to 100 ½ on analog scale) |  
            | Accuracy | ±3% ±2 digits (0 to 100 Ω) |  
            | Open circuit voltage | 5 V ±1 V |  
            | Test current | 200 mA (–0 mA +20 mA) (0.01 ½ to 9.99 Ω)
 20mA (±1 mA )
 (10.0 ½ to 99.9 Ω)
 |  
            | Zero offset at probe tips | 0.10Ω typical |  
            | Lead resistance zeroing | Up to 9.00 Ω |  
            | Buzzer | Variable limit 1Ω, 2Ω, 5Ω,10Ω, 20Ω |  
            | Resistance |  
            | Measurement | 0.01 kΩ to 1000 kΩ (0 to 1 MΩ on analog scale)
 |  
            | Accuracy | ±3% ±2 digits Open circuit voltage 5 V ±1 V
 Short circuit current 20 µA ± 5 µA
 |  
            | Voltage range | 0 to 600 V d.c. ±2% ±2 digits 10 mV to 600 V TRMS sinusoidal (40 to 400 Hz) ±2% ±2 digits
 0 to 1000 V on Analog scale
 Unspecified input level 0 - 10 mV (40 to 400 Hz)
 
 For non-sinusoidal waveforms additional specification apply:
 ±3% ±2 digits 101 mV to 600 V TRMS and ±8% ±2 digits 10 mV to 100 mV TRMS
 |  
            | Default Voltmeter | Operates at >25 V a.c. or d.c. on any range except OFF |  
            | Frequency | 40 - 450 Hz (40 Hz - 99.9 Hz) ±0.5% ±1 digit (100 Hz to450 Hz)
 |  
            | Result storage |  
            | Capacity | >1000 test results |  
            | Download | Bluetooth wireless |  
            | Bluetooth Class | Class II |  
            | Range | up to 10 m |  
            | Power |  
            | Power Supply | 5 x 1.5 V cells type IEC LR6 (AA, MN1500, HP7, AM3 R6HP) Alkaline NiMH rechargeable cells may be used. Battery life: 2200 insulation tests with duty cycle of 5 sec ON /55 sec OFF @ 1000 V into 1 MΩ
 |  
            | Dimensions |  
            | Instrument | 220 x 92 x 50 mm (8.66 in. x 3.63 in. x 1.97 in.) |  
            | Instrument and case | 456 x 178 x 89 mm (18 in. x 7 in. x 3.5 in.) |  
            | Weight |  
            | Instrument only | 590 gms (20.73 oz.), 775 gms (27.22 oz.) with boot |  
            | Instrument and case | 1.75kg (3.86 lb) |  
            | Fuse | Use only a 500 mA (FF) 1000 V 32 x 6 mm ceramic fuse of highbreaking capacity HBC 50 kA minimum. Glass fuses MUST NOT be fitted. |  
            | Safety Protection | The instruments meet EN 61010-1 (1995) to 600 V phase to earth, Category IV. Refer to safety warnings supplied. |  
            | E.M.C. | In accordance with IEC 61326 including amendment No.1 |  
            | Temperature effects |  
            | Temperature coefficient | <0.1&Omega per °C up to 1 G&Omega |  
            | Environmental |  
            | Operating range | -10 to +55° C |  
            | Operating humidity | 90% RH at 40° C max. |  
            | Storage temperature range | -25 to +70° C |  
            | Calibration Temperature | +20° C |  
            | Maximum altitude | 2000 m |  
            | Dust and water protection | IP54 Protected against dust and splashing water |    
    
        
            | Micro / Milli / Meg Ohmmeters/Megohmmeter / Insulation Resistance Testers Template |  
            | Type | Battery |  
            | IR Test Voltage | 1,000 V, 250 V, 500 V |  
            | Maximum Insulation Resistance | 200 G Ohms |  
            | Minimum Insulation Resistance | 0.01 Ohms (0.00000000001 G Ohms) |  
            | Variable Incremental Voltage | Yes |  
            | Display (Megohmmeter) | Digital |  
            | Continuity Test | Yes |  
            | Live Circuit Voltage Detection | Yes |  
            | Automated Test Results | Dielectric Absorption Ratio, Dielectric Discharge, Leakage Current, Other, Step Voltage |  
            | Power Supply | Battery |  
            | Timer | Yes |  
            | CAT Rating | IV |  
            | CAT Voltage | 600 V |  
         
            | Unique Features | True RMS voltage measurement – allows accurate voltage
 measurement on noisy lines
 
 Auto ranging voltage measurement
 – automatically adjusts
 range from millivolts to 600 V AC or DC, eliminating the
 need to keep changing ranges
 
 Live circuit warning
 – automatically warns of contact to a
 live circuit, voltage is displayed and testing is inhibited
 
 Auto fuse warning
 – warns of fuse failure automatically.
 No need to test the fuse manually.
 
 Buzzer select button
 – enable or disable buzzer as required
 with resistance also displayed on the screen
 |  
            | Warranty | 1 YEARS |  
            | Warranty Details | Years 2 and 3 require free registration of the unit. |  
            | Calibration Included | Factory Calibration |  
            | Power Supply Voltage | Battery Powered |  
            | Data Logging | No |  
            | IP Rating | IP54 |  
            | Product Weight | 27.22 OUNCES (1.70 LBS) |  
            | Battery Type | AA, NimH |  
            | Product Height | 2.32 IN |  
            | Product Length | 9.00 IN |  
            | Product Width | 4.25 IN |  
            | Shipping Weight | 32 OUNCES (2 LBS) |  
            | ECCN Number | 3A992 |  
            | HTS/Schedule B Number | 9030320000 |  
            | Country of Origin | United Kingdom |  
            | Shipping Height | 5 IN |  
            | Shipping Length | 20 IN |  
            | Shipping Width | 9 IN |  |  
					
                
        
        
              Accessories
            
            
                
                        
                            | Product | Price |  
                            |  | Megger 1007-157 
                                    Catalog #: 1007-157
SP5 Remote Switch Probe CATIV 600V | $215.23
 
 |  
                            |  | Megger 1007-160 
                                    Catalog #: 1007-160
Carry and Pouch Test | $122.23
 
 |  
                            |  | Megger 1007-464 
                                    Catalog #: 1007-464
Mains Charger Kit (MIT400/2 series Mk 2) | $153.23
 
 |  
                            |  | Megger 1007-637 
                                    Catalog #: 1007-637
Replacement lead set 2.50 kV (Red/Black/Blue) | $230.23
 
 |  
                            |  | Megger 1007-780 
                                    Catalog #: 1007-780
Lead Set Unfused (Red/Black/Green) for MIT481/2 and MIT485/2 | $230.23
 
 |  
                            |  | Megger 1007-781 
                                    Catalog #: 1007-781
Replacement lead set unfused (R/Blk/G) | $230.23
 
 |  
                            |  | Megger 1007-887 
                                    Catalog #: 1007-887
For MIT400/2 Series Test and Carry Pouch | $230.23
 
 |  
				 |