| Technical specifications | 
        
            | Measurement function | Alternating current | 
        
            | AC ampere range | 3 mA, 30 mA, 300 mA, 3 A, 30 A, 60 A | 
        
            | Range selection | mA A: manual selection 3 mA, 30 mA, 300 mA: automatic selection
 3 A, 30 A, 60 A: automatic selection
 | 
        
            | Range/Resolution | 3 mA [1] /0.001 mA 30 mA/0.01 mA
 300 mA/0.1 mA
 3 A/0.001 A
 30 A/0.01 A
 60 A/0.1 A
 | 
        
            | Accuracy – filter activated (40 to 70 Hz), filter off (40 to 1 kHz) [2]
 | 368/368 FC 3 mA – 30 A
 60 A
 | 1 % + 5 digits
 2 % + 5 digits
 | 
        
            | Accuracy – filter activated (40 to 70 Hz), filter off (40 to 1 kHz) [2]
 | 369/369 FC 3 mA to 30 A
 60 A
 | 1.5 % + 5 digits
 2 % + 5 digits
 | 
        
            | Frequency | 40 Hz to 1 kHz |  | 
        
            | Crest factor | 3 |  | 
        
            | After calibration accuracy is valid for one year. Accuracy is expressed as ± (% of reading + digits). Reference conditions 23 ± 5 °C and a maximum relative humidity of 80 %.
 
 [1] The minimum value is 10 µA rms. [2] Outside of the TC/°C 18 °C to 28 °C, 0.02 + 1
 | 
        
            | Physical | 
        
            | Display (LCD) | Digital readout: 3300 count | 
        
            | Display refresh rate | 4 times/sec | 
        
            | Maximum conductor diameter | 368/368 FC 369/369 FC
 | 40 mm 61 mm
 | 
        
            | Size (wxhxd) | 368/368 FC 369/369 FC
 | 101 mm x 234 mm x 46 mm 116 mm x 257 mm x 46 mm
 | 
        
            | Weight | 368/368 FC 369/369 FC
 | 500 g 600 g
 | 
        
            | Battery | 2 AA, IEC LR6, NEDA 15A, alkaline |  | 
        
            | Battery life | Expected battery life, without using backlight and spotlight, is more than 150 hours | 
        
            | Automatic shut-down | Meter automatically shuts down after 15 minutes of inactivity. | 
        
            | Safety and environmental specifications | 
        
            | General safety | IEC 61010-1: Pollution Level 2 | 
        
            | Measurement safety | IEC 61010-2-032: CAT III 600 V | 
        
            | Operating temperature | -10 °C to +50 °C | 
        
            | Storage temperature | -40 °C to +60 °C | 
        
            | Operating humidity | Non-condensing (<10 °C) 90 % relative humidity (10 °C to 30 °C)
 75 % relative humidity (30 °C to 40 °C)
 45 % relative humidity (40 °C to 50 °C)
 | 
        
            | Protection class | IEC 60529: IP30 (jaw closed) | 
        
            | Operating altitude | 2000 m | 
        
            | Storage altitude | 12000 m | 
        
            | Current sensor action category | IEC 61557-13: Class 1, = 100 A/m | 
        
            | Electromagnetic compatibility (EMC) | 
        
            | International | 
        
            | IEC 61326-1 | Industrial Electromagnetic Environment | 
        
            | CISPR 11 | Group 1 Class B | 
        
            | Group 1 | Generated inside the equipment and / or use radio frequency energy associated with conducting the energy for the device's own internal functions is essential.
 | 
        
            | Class B | Equipment for home appliances and residential buildings directly connected to a low voltage power supply network equipment. When this device is connected to a test object,
 it may exceed the emission levels produced by CISPR 11 requirements.
 _________________________________________________________________________
 Korea (KCC): A type of equipment (radio and communication equipment industry)
 | 
        
            | Class A | This product meets the requirements of industrial electromagnetic equipment, vendors or users should be aware of this. This device is intended for use in a commercial
 environment, instead of the home environment.
 _________________________________________________________________________
 USA (FCC): 47 CFR 15 B Subpart. In accordance with section 15.103 provides that the
 products are considered tax-free device.
 |