AEMC MN352
Catalog #: 2116.26
AC Current Probe Model MN352 (Jack - 10mV/A - 150A max)
- Overview
- Specifications
- Summary
- Accessories
Product Highlights
- Small, compact size
- Measurement range of 0.1 to 150A
- Large jaw opening accommodates conductors up to 250MCM
- Designed for DMMs, loggers, recorders and oscilloscopes
- 40Hz to 10kHz response
- 10mV/AAC output signals
- Conforms to EN 61010, 600V Cat. III safety standard
- CE Mark
- UL approved
Applications
- Measuring in breaker panels
- Industrial loads
- HVAC
- Residential and commercial sites
- Data logging/recording
| Electrical Specifications |
| Frequency Range |
40 to 10kHz |
| Limit Operating Conditions |
200A permanently to 1kHz; Derating above 3kHz: 200A x (1/0.333 F), F in kHz |
| Common Mode Voltage |
600VAC |
| Crest Factor |
3 @ 150Arms with an error (due to CF) of 3% |
| Current Overload |
240A for 10 min |
| Reference Conditions |
20° to 26°C, 20 to 75% RH, 48 to 65Hz, external magnetic field <40A/m, 48 to 65Hz sine wave, distortion factor less than 1%, no DC component, no external current carrying conductor, test sample centered. Load impedance 1MW |
| Working Voltage |
600VAC |
| Mechanical Specifications |
| Altitude |
Operating: 0 to 2000m; Non-operating: 0 to 12km |
| Colors |
Dark gray handles with red cover |
| Dimensions |
5.47 x 2.00 x 1.18" (139 x 51 x 30mm) |
| Drop Test |
Test per IEC 68-2-32: 1.0 m drop on 38 mm of Oak on concrete |
| Jaw Opening |
.84" (21mm) |
| Material |
Jaws: Polycarbonate with 10% fiberglass charge, Red UL 94 V0; Case: Polycarbonate |
| Maximum Bus Bar Size |
0.78 x 0.19" (20 x 5mm) |
| Maximum Cable Diameter |
One 0.78" & Oslash; (20mm) |
| Mechanical Shock |
100g per IEC 68-2-27 |
| Operating Temperature |
14° to 131°F (-10° to 55°C) |
| Operating Relative Humidity |
10° to 35°C 85% RH (without roll-off above 35°C) |
| Output |
Two standard safety banana jacks (4mm) |
| Protection Index (IP) |
IP 40 (IEC 529) |
| Impact Test |
IK04 0.5 J EN50102 |
| Storage Temperature |
-40° to 158°F (-40° to 70°C) |
| Vibration |
Test per IEC 68-2-6 |
| Weight |
6.5 oz (180g) |
| External Influences |
| Influence of Temperature |
£150 ppm/°K, or 0.15% of mV output per 10K° |
| Safety Reference Specifications |
| Safety Ratings |
EN 61010-2-32 |
| Agency Approvals |
CE Mark |
| Clamp Meters/Current Clamp Adaptors / Current Clamps Template |
| Type (Current Clamp Adaptors |
CT |
| Maximum Current |
150 A |
| Current Output |
No |
| Voltage Output |
Yes |
| AC Current Only |
Yes |
| AC/DC Current |
No |
| Current Accuracy |
3% |
| Phase Shift |
3 |
| Maximum Conductor Size Fixed |
0.78 IN |
| CAT Rating |
III |
| CAT Voltage Rating (V) |
600V |
| Connector |
Other |
| Style (Current Clamps) |
Fixed |
| Battery Powered |
No |
| Externally Powered |
No |
| Data Logging |
No |
| Unique Features |
Max size conductor 0.78" |
| Warranty |
12 MONTHS (1 YEARS) |
| Calibration Included |
Factory Calibration |
| Safety Approval |
CE, CSA, UL |
| IP Rating |
IP40 |
| Product Weight |
6.5 OUNCES (0.4062 LBS) |
| Shipping Weight |
3 LBS |
| ECCN Number |
EAR99 |
| HTS/Schedule B Number |
9030908060 |
| Country of Origin |
United States |
| UPC |
685338030181 |
|
Accessories
| Product |
Price |
 |
AEMC 2133.73
Catalog #: 2133.73
Bag Extra Large Classic Tool Bag (Replacement for Models 3945/3945-B, 6240, 6250, 6471, 6505, 5050, 5060, 5070, 8333, 8335, 8336 and PEL 105)
|
$100.23
|
 |
AEMC 2152.24
Catalog #: 2152.24
Lead Set of 2, Color-coded (red/black) 5 ft Safety Leads {Rated 1000V CAT IV}
|
$24.21
|
|
|
|