Fluke 116
Catalog #: 2538803
HVAC Multimeter with Temperature and Microamps
- Overview
- Specifications
- Summary
- Cases
- Current Clamps/Meter
- Accessories
Product Highlights
- Built in thermometer for HVAC applications
- Microamps to test flame sensors
- LoZ: helps prevent false readings due to ghost voltage
- Large white LED backlight to work in poorly lit areas
- Resistance, continuity, frequency and capacitance
- Min/Max/Average with elapsed time to record signal fluctuations
- Compact ergonomic design for one-handed operation
- Compatible with optional magnetic hanger (ToolPak)
- CAT III 600 V safety rated
- True RMS
- .5% Accuracy
- 28% larger digits
- 6000 counts
- Bargraph
- Backlight
- Min-max recording
- Display hold
- Microamps
- Temperature
- LoZ
- AutoV
Each Unit Includes
- Fluke TL75 Test Leads
- Fluke 80BK Integrated Temperature Probe
- Holster
- User’s Manual
- 9V battery (installed)
| Specifications |
| Maximum voltage between any terminal and earth ground |
600 V |
| Surge protection |
6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2 |
| Display |
Digital: 6,000 counts, updates 4 per second |
| Bar graph |
33 segments, updates 32 per second |
| Operating temperature |
-10°C to + 50°C |
| Storage temperature |
-40°C to + 60°C |
| Battery type |
9 volt Alkaline, NEDA 1604A/ IEC 6LR61 |
| Battery life |
400 hours typical, without backlight |
| Accuracy Specifications |
| DC millivolts |
Range/resolution |
600.0 mV / 0.1 mV |
| Accuracy |
±([% of reading] + [counts]): 0.5% + 2 |
| DC volts |
Range/resolution |
6.000 V / 0.001 V |
| 60.00 V / 0.01 V |
| 600.00 V / 0.1 V |
| Accuracy |
±([% of reading] + [counts]): 0.5% + 2 |
| Auto volts |
Range/resolution |
600.0 V / 0.1 V |
| Accuracy |
2.0% + 3 (DC, 45 Hz to 500 Hz) |
| 4.0% + 3 (500 Hz to 1 kHz) |
| AC millivolts¹ True RMS |
Range/resolution |
600.0 mV / 0.1 mV |
| Accuracy |
1.0% + 3 (DC, 45 Hz to 500 Hz) |
| 2.0% + 3 (500 Hz to 1 kHz) |
| AC volts¹ True RMS |
Range/resolution |
6.000 V / 0.001 V |
| 60.00 V / 0.01 V |
| 600.0 V / 0.1 V |
| Accuracy |
1.0% + 3 (DC, 45 Hz to 500 Hz) |
| 2.0% + 3 (500 Hz to 1 kHz) |
| Continuity |
Range/resolution |
600 O / 1 O |
| Accuracy |
Beeper on < 20 O, off > 250 O detects opens or shorts of |
| 500 µs or longer. |
| Ohms |
Range/resolution |
600.0 O / 0.1 O |
| 6.000 kO / 0.001 kO |
| 60.00 kO / 0.01 kO |
| 600.0 kO / 0.1 kO |
| 6.000 MO / 0.001 MO |
| Accuracy |
0.9% + 1 |
| Range/Resolution |
40.00 MO / 0.01 MO |
| Accuracy |
5% + 2 |
| Diode Test |
Range/resolution |
2.00 V / 0.001 V |
| Accuracy |
0.9% + 2 |
| Capacitance |
Range/resolution |
1000 nF / 1 nF |
| 10.00 µF / 0.01 µF |
| 100.0 µF / 0.1 µF |
| 9999 µF / 1 µF |
| 100 µF to 1000 µF |
| Accuracy |
1.9% + 2 |
| Range/resolution |
> 1000 µF |
| Accuracy |
5% + 20% |
| Lo-Z Capacitance |
Range |
1 nF to 500 µF |
| Accuracy |
10% + 2 typical |
| Temperature² |
Range/resolution |
-40°C to 400°C / 0.1°C |
| (Type-K thermocouple) |
Accuracy |
1% + 10² |
| |
Range/resolution |
-40°F to 752°F / 0.2°F |
| |
Accuracy |
1% + 18² |
| AC µA true-rms (45 Hz to 500 Hz) |
Range/resolution |
600.0 µA / 0.1 µA |
| Accuracy |
1.5% + 3 |
| DC µamps |
Range/resolution |
600.0 µA / 0.1 µA |
| Accuracy |
1.0% + 2 |
| Hz (V or A input)² |
Range/resolution |
99.99 Hz / 0.01 Hz |
| 999.99 Hz / 0.1 Hz |
| 9.999 Hz / 0.001 Hz |
| 50.00 Hz / 0.01 Hz |
| Accuracy |
0.1% + 2 |
| 1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. |
| 2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. |
| 3. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current. |
| 4. Temperature Range/Resolution: -40°F to 752°F / 0.2°F. |
| Mechanical and General Specifications |
| Size |
167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) |
| Weight |
550 g |
| Warranty |
3 years |
| Type |
Digital |
| Style |
Hand-Held |
| Measures AC V |
Yes |
| Measures DC V |
Yes |
| Measures AC A |
Yes |
| Measures DC A |
Yes |
| True RMS |
Yes |
| Maximum Voltage AC |
600 V |
| Minimum Voltage AC |
0.1 mV |
| Resolution AC Volts |
0.1 mV |
| Maximum Voltage DC |
600 V |
| Minimum Voltage DC |
0.1 mV |
| Resolution DC Volts |
0.1 mV |
| Maximum Current AC |
600 uA (0.0006 A) |
| Minimum Current AC |
0.1 uA (0.00010 mA) |
| Resolution AC Current |
0.1 uA (0.00010 mA) |
| Maximum Current DC |
600 uA (0.0006 A) |
| Minimum Current DC |
0.1 uA (0.00010 mA) |
| Resolution DC Current |
0.1 uA (0.00010 mA) |
| Basic Accuracy V DC |
0.5% |
| # Digit Display |
3.5 |
| Counts |
6000 . |
| Backlight |
Yes |
| Manual/Autoranging |
Both |
| Dual Display |
No |
| Analog Bargraph on Display |
Yes |
| Decibels |
No |
| Resistance |
Yes |
| Frequency |
Yes |
| Continuity |
Yes |
| Capacitance |
Yes |
| Temperature |
Yes |
| Diode Testing |
Yes |
| CAT Rating |
III |
| CAT Voltage |
600 V |
| Peak Hold |
No |
| Overload Protector |
Yes |
| Kelvin 4-Wire Measurement Capability |
No |
| Intrinsically Safe |
No |
| Wireless Display |
No |
| Data Hold |
Yes |
| Low-Pass Filter |
No |
| |
| Unique Features |
•Built-in thermometer for HVAC applications
•Microamps to test flame sensors
•Low input impedance: helps prevent false readings due to ghost voltage
•Large white LED backlight to work in poorly lit areas
•Resistance, continuity, frequency and capacitance
•Min/Max/Average with elapsed time to record signal fluctuations
•Compact ergonomic design for one-handed operation
•Compatible with optional magnetic hanger (ToolPak™)
•CAT III 600 V safety rated |
| Warranty |
3 YEARS |
| Calibration Included |
Factory Calibration |
| Power Supply Voltage |
Battery Powered |
| Safety Approval |
CSA, UL |
| Data Logging |
No |
| Interfaces I/O |
Analog Output, Analog Input |
| IP Rating |
IP42 |
| Product Weight |
1.21 LBS |
| Battery Type |
9v |
| Product Height |
1.82 IN |
| Product Length |
6.57 IN |
| Product Width |
3.31 IN |
| Shipping Weight |
1.34 LBS |
| ECCN Number |
3A992 |
| Country of Origin |
China |
| Shipping Height |
5.91 IN |
| Shipping Length |
12.99 IN |
| Shipping Width |
11.02 IN |
| UPC |
095969324199 |
|
Cases
| Product |
Price |
 |
Fluke C115
Catalog #: 2826063
Soft Carrying Case
|
$70.26
|
 |
Fluke C125
Catalog #: 646858
Compact Soft Case
|
$60.24
|
 |
Fluke C35
Catalog #: 2826056
Soft Carrying Case
|
$60.24
|
 |
Fluke C50
Catalog #: 762823
Meter Case
|
$58.24
|
Current Clamps/Meter
| Product |
Price |
 |
Fluke I200
Catalog #: 664755
Current Probe
|
$219.24
|
 |
Fluke I400
Catalog #: 2277225
Current Clamp Adaptor
|
$199.24
|
 |
Fluke I400S
Catalog #: 2277202
Current Probe
|
$364.24
|
 |
Fluke I410
Catalog #: 617727
AC/DC Current Clamp Adaptor
|
$329.24
|
 |
Fluke I410-KIT
Catalog #: 2097005
AC/DC Current Clamp and Carry Case Kit
|
$389.24
|
Accessories
| Product |
Price |
 |
Fluke 80PK-18
Catalog #: 3448859
Pipe Clamp Temperature Probe Kit
|
$482.24
|
 |
Fluke 80PK-9
Catalog #: 1288229
General Purpose Probe
|
$104.24
|
 |
Fluke 80TK
Catalog #: 736736
Module Thermocouple
|
$209.24
|
 |
Fluke AC285
Catalog #: 1610159
SureGrip Alligator Clips
|
$60.24
|
 |
Fluke AC87
Catalog #: 1278079
Heavy Duty Bus Bar Clip Set
|
$60.24
|
 |
Fluke FTPL-1
Catalog #: 3869437
Fused Test Probe Set
|
$178.24
|
 |
Fluke L206
Catalog #: 2098595
Deluxe LED Hat Light
|
$80.24
|
 |
Fluke TL175
Catalog #: 3521976
TwistGuard™ Test Leads
|
$45.24
|
 |
Fluke TL220
Catalog #: 2003625
Industrial Test Lead Set
|
$117.26
|
 |
Fluke TL223
Catalog #: 2003633
SureGrip Electrical Test Lead Set
|
$117.26
|
 |
Fluke TL224
Catalog #: 1610198
SureGrip Insulated Test Leads
|
$46.26
|
 |
Fluke TL71
Catalog #: 1274382
Premium Test Lead Set
|
$45.24
|
 |
Fluke TL75
Catalog #: 855705
Hard Point Test Lead Set
|
$45.24
|
 |
Fluke TLK-220
Catalog #: 2097010
Industrial Test Lead Kit
|
$218.24
|
 |
Fluke TP74
Catalog #: 1541649
Lantern Tip Test Probes
|
$60.24
|
 |
Fluke TPAK
Catalog #: 1281997
Meter Hanging Kit
|
$75.25
|
|
|
|