Extech 412400
Catalog #: 412400
Multifunction Process Calibrator Precision Source
- Overview
- Specifications
- Summary
Product Highlights
- Source 0 to 24mA with 0.01mA resolution
- Measure 0 to 50mA (0.1mA resolution)
- Select Type K, J, or T thermocouple for precision calibrations in °F/°C or mV
- Output 0 to 1999mV or 0 to 10.00V
- Measure 0 to 19.99V
Each Unit Includes
- 6 - AA Batteries
- 1 - Calibration Cable With Spade Lug Terminals
| Specifications |
Range |
Accuracy (of reading) |
| Source |
| Current |
0 to 24mA, -25% to +125% |
±(0.075% + 1 digit) or ± 3 digits, whichever is greater |
| Voltage |
0 to 10V |
±(0.075% + 1 digit) or ± 3 digits, whichever is greater |
| Type J |
-58 to 1830°F (-50 to 1000°C) |
±(0.15% + 1.8°F or 1°C) |
| Type K |
-58 to 2498°F (-50 to 1370°C) |
±(0.15% + 1.8°F or 1°C) |
| Type T |
-184 to 752°F (-120 to 400°C) |
±(0.15% + 1.8°F or 1°C) |
| Loop Power |
24V |
±(10µV ± 1 digit) |
| Max. Load |
1000Ω @ 24mA |
| Measure |
| Current |
0 to 50mA, -25% to +230% |
±(0.075% + 1 digit) or ± 3 digits, whichever is greater |
| Voltage |
0 to 20V |
±(0.075% + 1 digit) or ± 3 digits, whichever is greater |
| Type J |
-58 to 1830°F (-50 to 1000°C) |
±(0.15% + 1.8°F or 1°C) |
| Type K |
-58 to 2498°F (-50 to 1370°C) |
±(0.15% + 1.8°F or 1°C) |
| Type T |
-184 to 752°F (-120 to 400°C) |
±(0.15% + 1.8°F or 1°C) |
| Dimensions/Weight |
3.8 x 4.7 x 2.0" (96 x 118 x 45mm)/12oz (340g) |
| Process / Calibration/Multifunction Calibrators Template |
| Type |
Hand Held |
| Measure Voltage |
Yes |
| Loop Voltage Min |
0 V |
| Simulate Loop Voltage |
Yes |
| Loop Voltage Max |
24 V |
| Voltage Measurement Max |
20 V |
| Voltage Measurement Min |
0 V |
| Source/Simulate DC Current |
Yes |
| Measure DC Current |
Yes |
| Current Measurement Max |
24 mA |
| Current Measurement Min |
0 mA |
| Source/Simulate Resistance |
No |
| Measure Resistance |
No |
| Source/Simulate Frequency |
No |
| Measure Frequency |
No |
| Measure RTD |
No |
| Measure Thermocouples |
Yes |
| Source/Simulate Pressure |
No |
| Pressure Modules Available |
No |
| Hart Compatible |
No |
| FieldBus Compatible |
No |
| Backlighted |
No |
| Graphical Screen |
No |
| Types RTD/Thermocouples Accepted |
J, K, T |
| Intrinsically Safe(Calibrators) |
No |
| Unique Features |
Source 0 to 24mA with 0.01mA resolution
Single/continuous step function for Voltage and Current
Select Type K, J, or T thermocouple for precision calibrations in °F/°C or mV
Output 0 to 1999mV or 0 to 10.00V
Measure 0 to 50mA (0.1mA resolution)
Measure 0 to 19.99V
Self-contained 24V loop power supply drives current loads up to 1000O
5 stored calibration values of each type for fast calibrations |
| Warranty |
1 YEARS |
| Safety Approval |
CE |
| Product Weight |
12 OUNCES (0.75 LBS) |
| Product Height |
2 IN |
| Product Length |
3.8 IN |
| Product Width |
4.7 IN |
| Data Logging |
No |
| HTS/Schedule B Number |
9027.80.4590 |
| ECCN Number |
EAR99 |
| Calibration Included |
Factory Calibration |
| Battery Type |
AA |
| Power Supply Voltage |
Battery Powered |
| Country of Origin |
Taiwan |
| Shipping Height |
3.00 IN |
| Shipping Length |
11.50 IN |
| Shipping Width |
10.00 IN |
|
|
|
|