				Fluke FL62MAX+/T+PRO/1AC
                
                
                
 			 
				Catalog #: 4296083
Handheld Infrared Thermometer, Electrical Tester, Voltage Detector VoltAlert
 
 
                
                    OverviewSpecificationsSummaryCasesAccessories 	
                    
				        
                        Product HighlightsFluke 62 MAX+ IR THERMOMETER 
    Dust and water-resistant: IP54 rated for dust and water resistance.Rugged: 3-meter (9.8-foot) drop tested.Ergonomically designed: Completely redesigned for a more natural hand fit.Small and lightweight; clips to your tool belt or belt loop or easily fits into your tool box. Additional Features 
    Distance to spot: Precise laser technology makes for more accurate and repeatable measurements.Dual lasers: The Fluke 62+ MAX has dual rotating lasers to help you identify area to be measured. The measurement area is the spot between the dots.Large, backlit display: Large screen makes data easier to read, even in dark areas.Min/Max/Avg/Dif: Displays the minimum, maximum or average temperature, or the difference between two measurements.Alarm: Hi and Lo alarms for rapid display of measurements outside the limits.Power: Both the Fluke 62 MAX and Fluke 62+ MAX are powered by a single, standard AA battery. Fluke T+Pro Electrical Tester 
    Backlit LCD display for easier viewingDisplay resolution of 0.1 V, ideal for troubleshooting low-voltage lightingResistance (Ohms) to 9.99 kOhmsRotary Field IndicationDisplay Hold for easier viewing in hard-to-test areas3 forms of ac/dc voltage indication: light, sound, and vibration for added user protection and convenienceDetect live voltage even when the batteries are deadExtra heavy-duty, replaceable test leads for more flexibility and durabilityCAT IV 600 V, CAT III 1000 V rated for added user protectionContinuity beeperBright LED flashlight for work in poorly lit areasGFCI TripOn/Off switchable beeper, selectable according to your environmentCompliant with latest NFPA 70E recommendationsReplaceable test probes for added flexibility and convenienceConvenient probe storage on the backProbe holder for easier testingHazardous voltage warning light for added user protectionTest lead strap included for better test lead managementAC/DC Voltage: 12 V – 600 V on LED bar, 10.2 V – 600 V on LCDAuto-off saves battery power2-year warranty Fluke 1AC ACV DETECTOR 90-1000V
 
    Voltbeat technology and continuous self-test — so you always know it’s workingUpon detection, tip glows and beeper soundsCAT IV 1000 V for added protectionExpanded range: 90 V to 1000 V AC or 200 V to 1000 V AC depending on model20 V to 90 V AC control circuit model also availableTwo-year warranty Each Unit Includes
    Infrared Thermometer, -22-1202°F Range, 12:1 Ratio (62 MAX+)Electrical Tester with Rotary Field Indicator, Resistance and Backlit LCD Display (T+Pro)VoltAlert AC Voltage Tester, 90-1000V AC (1AC-A1-II)Test Lead SetSoft Carrying Case (C115)User Manual4X AA BatteriesTest Lead Wrap 
                        
    
        
            | IR THERMOMETER |  
            | Specifications |  
            | Temperature Range | -30 °C to 500 °C (-22 °F to 932 °F) -30 °C to 650 °C (-22 °F to 1202 °F)
 |  
            | Accuracy | ±1.5 °C or ±1.5% of reading, whichever is greater-10 °C to 0 °C: ±2.0-30 °C to -10 °C: ±3.0 ±1.0 °C or ±1.0% of reading, whichever is greater-10 °C to 0 °C: ±2.0-30 °C to -10 °C: ±3.0 |  
            | Response Time (95%) | <500 ms (95% of reading) <300 ms (95% of reading)
 Spectral Response 8 to 14 microns
 Emissivity 0.10 to 1.00
 |  
            | Display Resolution | 0.1 °C (0.2 °F) |  
            | Repeatability of Readings | ±0.8% of reading or <±1.0 °C (2 °F), whichever is greater ±0.5% of reading or <±0.5 °C (1 °F), whichever is greater
 |  
            | Power | AA battery |  
            | Battery Life | 10 hours with laser and backlight on 8 hours with laser and backlight on
 |  
            | Physical Specifications | 
                
                    
                        | Weight | 255 g (8.99 oz) |  
                        | Size | (175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches |  
                        | Operating Temperature | 0 °C to 50 °C (32 °F to 122 °F) |  
                        | Storage Temperature | -20 °C to 60 °C (-4 °F to 140 °F), (without battery) |  
                        | Operating Humidity | 10 % to 90 % RH non-condensing at 30 °C (86 °F) |  
                        | Operating Altitude | 2000 meters above mean sea level |  
                        | Storage Altitude | 12,000 meters above mean sea level |  
                        | IP Rating | IP 54 per IEC 60529 |  
                        | Drop Test | 3 meters |  
                        | Vibration and Shock | IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms |  
                        | EMC | EN 61326-1:2006 EN 61326-2:2006 |  |  
            | Standards and Agency Approval | Compliance EN/IEC 61010-1: 2001 Laser Safety FDA and EN 60825-1 Class II
 |    
    
        
            | Electrical Tester |  
            | Temperature | Operating: -10 C to 55 C (14 F to 131 F) Storage: -30 C to 60 C (- 22 F to 140 F)
 |  
            | Relative humidity | 0 C to 30 C (3 F to 86 F): 90 % 30 C to 40 C (86 F to 104 F): 75 %
 40 C to 50 C (104 F to 1 F): 45 %
 |  
            | Altitude | Operating: 2,000 m (approx. 6,561.6 ft Storage: 10,000 m (approx. 3 ,808.4 ft)
 |  
            | Battery type/life | AAA (2); 40 hours |  
            | Shock, vibration | Sinusoidal vibration per MIL-PRF- 8800F for a Class instrument |  
            | Safety | ISA-8 .0 .01 (IEC 61010-1 Mod) Second Edition, CAN/CSA-C . No. 61010-1 Second Edition, IEC 61010 - 1 to 1000 V CAT III/600 V CAT IV
 Compliance to NFPA 70E1
 |  
            | AC Bandwidth | 45 Hz to 66 Hz |  
            | Maximum working voltage | 1000 V ac/dc |  
            | Maximum measurable voltage | 600 V ac/dc |  
            | Duty cycle | Indefinitely for voltages up to 240 V. For voltages between 40 V and 600 V the duty cycle is 30 s on / 300 s off.
 For voltages above 40 V the tester must connect to a voltage source only for a MAXIMUM of 30 s and then disconnect for a MINIMUM of 300 s.
 |  
            | Voltage hazard LED | LEDs turn on at voltages > 30 V ac/dc + 35 % |  
            | LED voltage indication levels | 1 V, 4 V, 48 V, 1 0 V, 08 V, 40 V, 77 V, 480 V, 600 V |  
            | LED voltage indication levels for Canadian version | 1 V, 4 V, 48 V, 1 0 V, 08 V, 40 V, 347 V, 480 V, 600 V |  
            | LEDs | LEDs turn on between 70 % and 85 % of the indicated voltage on the LED, except for the 1 V LED which turns on between 50 % and 100 %. |  
            | Accuracy | AC voltage: + (3 % rdg + digits) DC voltage: + (2 % rdg + digits)
 Resistance: + (5 % rdg + 3 digits)
 |  
            | LCD Resolution | 0.1 V for voltages < 50 V, 1 V for voltages >50 V 0.01 k  ¸ for resistance measurement (For T+PRO Only)
 |  
            | GFCI Test current | 100 V - 00 V at 0 mA - 35 mA for 1 s |  
            | Standard input test current | < 5 mA |  
            | Size (H x W x L) | 1.3 in x .15 in x 7.6 in (3.3 cm x 5.46 cm x 19.3 cm ) |  
            | Weight | 9.9 oz (0.28 kg) |    
    
        
            | ACV DETECTOR 90-1000V |  
            | Operating principle | Senses the steady state electrostatic ?eld produced by ac voltage through insulation without requiring contact to the bare conductor. A red glow at the tip and a beeping noise (if not switched OFF) indicates the presence of voltage. |  
            | Voltage sensing ranges | Nominally, 90 V AC to 1000 V AC or 200 V AC to 1000 V AC depending on model, 45 Hz to 405 Hz; also a 20 V to 90 V control circuit model |  
            | Detector tip style | Blade or round, depending on model |  
            | Light source | One high intensity red LED |  
            | Agency Approvals | c CSA us, CE, TUV, C-Tick |  
            | Safety Rating | 1000 V, CAT IV |  
            | IP Rating | IP 40 |  
            | Operating temperature | -10 °C to 50 °C |  
            | Operating humidity ranges | 0 % to 95 % (0 °C to 30 °C) 0 % to 75 % (30 °C to 40 °C)
 0 % to 45 % (40 °C to 55 °C)
 |  
            | Operating Altitude | 3000 meters |  
            | Batteries | 2 AAA alkaline batteries included |    |  
					
                
        
        
              Cases
            
            
                
                        
                            | Product | Price |  
                            |  | Fluke C50 
                                    Catalog #: 762823
Meter Case | $58.24
 
 |  
                            |  | Fluke C550 
                                    Catalog #: 1547919
Tool Bag | $145.24
 
 |  
              Accessories
            
            
                
                        
                            | Product | Price |  
                            |  | Fluke 80PR-60 
                                    Catalog #: 2148313
RTD Temperature Probe | $134.24
 
 |  
				 |  
     |  |