				Fluke FL62MAX+/323/1AC
                
                
                
 			 
				Catalog #: 4296076
Handheld Infrared Thermometer, True-RMS Clamp Meter, Voltage Detector
 
 
                
                    OverviewSpecificationsSummaryCasesAccessories 	
                    
				        
                        Product HighlightsFluke 62 MAX+ Handheld Infrared Thermometer 
    Ergonomically designed: Completely redesigned for a more natural hand fit.Small and lightweight; clips to your tool belt or belt loop or easily fits into your tool box.Dust and water-resistant: IP54 rated for dust and water resistance.Rugged: 3-meter (9.8-foot) drop tested. Additional Features 
    Distance to spot: Precise laser technology makes for more accurate and repeatable measurements.Dual lasers: The Fluke 62+ MAX has dual rotating lasers to help you identify area to be measured. The measurement area is the spot between the dots.Large, backlit display: Large screen makes data easier to read, even in dark areas.Min/Max/Avg/Dif: Displays the minimum, maximum or average temperature, or the difference between two measurements.Alarm: Hi and Lo alarms for rapid display of measurements outside the limits.Power: powered by a single, standard AA battery. Fluke 323 True-RMS Clamp Meter 
    400.0 A ac current measurement600.0 V ac and dc voltage measurementTrue-rms ac voltage and current for accurate measurements on non-linear signalsResistance measurement up to 40 kΩ with continuity detectionSlim, ergonomic designCAT IV 300V/CAT III 600 V safety ratingHold buttonTwo-year warrantySoft carrying case Fluke 1AC-II VoltAlert Voltage Detector 
    Voltbeat technology and continuous self-test — so you always know it’s workingUpon detection, tip glows and beeper soundsCAT IV 1000 V for added protectionExpanded range: 90 V to 1000 V AC or 200 V to 1000 V AC depending on model20 V to 90 V AC control circuit model also availableTwo-year warranty Each Unit Includes
    Infrared Thermometer, -22-1202°F Range, 12:1 Ratio (62 MAX+)True-RMS AC/DC Clamp Meter, 400A AC, 600V AC/DC (323)VoltAlert AC Voltage Tester, 90-1000V AC (1AC-A1-II)Test Lead SetSoft Carrying Case (C115)User Manual 
                         Fluke 62 MAX+ Handheld Infrared Thermometer 
    
        
            | Specifications |  
            | Temperature Range | Fluke 62 MAX -30 °C to 500 °C (-22 °F to 932 °F) Fluke 62+ MAX -30 °C to 650 °C (-22 °F to 1202 °F)
 |  
            | Accuracy | Fluke 62 MAX ±1.5 °C or ±1.5% of reading, whichever is greater-10 °C to 0 °C: ±2.0-30 °C to -10 °C: ±3.0Fluke 62+ MAX ±1.0 °C or ±1.0% of reading, whichever is greater-10 °C to 0 °C: ±2.0-30 °C to -10 °C: ±3.0 |  
            | Response Time (95%) | Fluke 62 MAX <500 ms (95% of reading) Fluke 62+ MAX <300 ms (95% of reading)
 Spectral Response 8 to 14 microns
 Emissivity 0.10 to 1.00
 |  
            | Display Resolution | 0.1 °C (0.2 °F) |  
            | Repeatability of Readings | Fluke 62 MAX ±0.8% of reading or <±1.0 °C (2 °F), whichever is greater Fluke 62+ MAX ±0.5% of reading or <±0.5 °C (1 °F), whichever is greater
 |  
            | Power | AA battery |  
            | Battery Life | Fluke 62 MAX 10 hours with laser and backlight on Fluke 62+ MAX 8 hours with laser and backlight on
 |  
            | Physical Specifications | 
                
                    
                        | Weight | 255 g (8.99 oz) |  
                        | Size | (175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches |  
                        | Operating Temperature | 0 °C to 50 °C (32 °F to 122 °F) |  
                        | Storage Temperature | -20 °C to 60 °C (-4 °F to 140 °F), (without battery) |  
                        | Operating Humidity | 10 % to 90 % RH non-condensing at 30 °C (86 °F) |  
                        | Operating Altitude | 2000 meters above mean sea level |  
                        | Storage Altitude | 12,000 meters above mean sea level |  
                        | IP Rating | IP 54 per IEC 60529 |  
                        | Drop Test | 3 meters |  
                        | Vibration and Shock | IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms |  
                        | EMC | EN 61326-1:2006 EN 61326-2:2006 |  |  
            | Standards and Agency Approval | Compliance EN/IEC 61010-1: 2001 Laser Safety FDA and EN 60825-1 Class II
 |  Fluke 323 True-RMS Clamp Meter
 
    
        
            | Specifications |  
            | AC current |  
            | Range | - |  
            | Accuracy | 2 % ± 5 digits (45 Hz to 65 Hz)
 2.5 % ± 5 digits
 (65 Hz to 400 Hz)
 |  
            | DC current |  
            | Range | - |  
            | Accuracy | - |  
            | AC voltage |  
            | Range | 600.0 V |  
            | Accuracy | 1.5 % ± 5 digits |  
            | DC voltage |  
            | Range | 600.0 V |  
            | Accuracy | 1.0 % ± 5 digits |  
            | Resistance |  
            | Range | 400.0 Ω / 4000 Ω |  
            | Accuracy | 1 % ± 5 digits |  
            | Continuity | = 7 Ω |  
            | Capacitance | - |  
            | Frequency | - |  
            | AC response | True-rms |  
            | Backlight | - |  
            | Data hold | Yes |  
            | Contact temperature | - |  
            | Min/Max | - |  
            | Size |  
            | H x W x D (mm) | 207 x 75 x 34 |  
            | Max wire diameter | 30 mm (600 MCM) |  
            | Weight | 265 g |  
            | Category rating | CAT III 600 V CAT IV 300 V
 |  Fluke 1AC-A1-II Voltage Detector VoltAlert
 
    
        
            | Specifications |  
            | Operating principle | Senses the steady state electrostatic ?eld produced by ac voltage through insulation without requiring contact to the bare conductor. A red glow at the tip and a beeping noise (if not switched OFF) indicates the presence of voltage. |  
            | Voltage sensing ranges | Nominally, 90 V AC to 1000 V AC or 200 V AC to 1000 V AC depending on model, 45 Hz to 405 Hz; also a 20 V to 90 V control circuit model |  
            | Detector tip style | Blade or round, depending on model |  
            | Light source | One high intensity red LED |  
            | Agency Approvals | c CSA us, CE, TUV, C-Tick |  
            | Safety Rating | 1000 V, CAT IV |  
            | IP Rating | IP 40 |  
            | Operating temperature | -10 °C to 50 °C |  
            | Operating humidity ranges | 0 % to 95 % (0 °C to 30 °C) 0 % to 75 % (30 °C to 40 °C)
 0 % to 45 % (40 °C to 55 °C)
 |  
            | Operating Altitude | 3000 meters |  
            | Batteries | 2 AAA alkaline batteries included |    
    
        
            | Clamp Meters/Clamp Meters Template |  
            | Type | Standard Style |  
            | True RMS | Yes |  
            | Maximum Current AC | 400 A |  
            | Maximum Voltage AC | 600 V |  
            | Maximum Voltage DC | 600 V |  
            | Basic Voltage Accuracy | AC: 1.5 % ± 5 digits DC: 1.0 % ± 5 digits
 |  
            | Maximum Conductor Size | 30 MM (1.18 IN) |  
            | Auto Ranging/Manual | Auto Ranging |  
            | Detachable Jaw | No |  
            | Rotating Jaw / Swivel | No |  
            | Peak Hold | Yes |  
            | Min/Max | No |  
            | In-Rush Current | No |  
            | Dual Display | No |  
            | Analog Bargraph on Display | No |  
            | Backlight | Yes |  
            | Remote Display | No |  
            | Resistance | Yes |  
            | Frequency | No |  
            | Continuity | Yes |  
            | Capacitance | No |  
            | Temperature (K T/C) | No |  
            | Temperature (IR Sensor) | No |  
            | Diode Testing | No |  
            | CAT Rating | IV |  
            | CAT Voltage | 300 V, 600 V |  
            | Overload Protector | No |  
            | Voltage / Continuity and Non-Contact Testers/Non-Contact Voltage and Current Detectors Template |  
            | Style (voltage) | Pen |  
            | AC Volts | Yes |  
            | DC Volts | No |  
            | Voltage Display | No |  
            | Audible Alert | Yes |  
            | Visual Alert | Yes |  
            | Data Hold | No |  
            | Resistance Testing | No |  
            | Continuity Test | No |  
            | Continuous Self Test | Yes |  
            | Thermometers/IR Thermometers Template |  
            | IR Temperature Max | 650 C (1202 F) |  
            | IR Temperature Min | -30 C (-22 F) |  
            | Field View Ratio (Spot Ratio) | 12:1 |  
            | Accuracy | ≥0°C: ±1.5°C or ±1.5 % of reading, whichever is greater (≥32°F: ±3°F or ±1.5 % of reading, whichever is greater)
 ≥-10°C to <0°C: ±2°C(≥14°F to <32°F: ±4°F)
 < -10°C: ±3°C(<14°F: ±6°F)
 |  
            | Laser Pointer | Yes |  
            | Emissivity Adjustable | Yes |  
            | Alarm | Yes |  
            | Max./Min. | Yes |  
            | Memory Recall | No |  
            | Thermocouple Input | No |  
            | Food Safe | No |  
         
            | Data Logging | No |  
            | Unique Features | 62 MAX+ -10 foot drop test proof
 -Dust and water-resistant: IP54 rated for dust and water resistance.
 -Battery life 10 hours with laser and backlight on
 -Dual Lasers
 -Min/Max/Avg/Dif function
 -Hi and Lo alarm
 |  
            | Power Supply Voltage | Battery Powered |  
            | IP Rating | IP54 |  
            | Battery Type | AA |  
            | Country of Origin | China |  |  
					
                
        
        
              Cases
            
            
                
                        
                            | Product | Price |  
                            |  | Fluke C50 
                                    Catalog #: 762823
Meter Case | $58.24
 
 |  
                            |  | Fluke C550 
                                    Catalog #: 1547919
Tool Bag | $145.24
 
 |  
              Accessories
            
            
                
                        
                            | Product | Price |  
                            |  | Fluke 80PR-60 
                                    Catalog #: 2148313
RTD Temperature Probe | $134.24
 
 |  
				 |  
     |  |