				Fluke 1775/BASIC
                
                
                
 			 
				Catalog #: 5272784
Three-Phase Power Quality Analyzer with Soft Carrying Case (No I17XX-FLEX1500 24 Probe)
 
 
                
                    OverviewSpecificationsSummaryAccessories 	
                    
				        
                        Product Highlights
    Three-phase power quality analyzerDoes not Includes I17XX-FLEX1500 24 Probe and Includes Soft Carrying CaseAutomatically measure power and power quality      parametersCritical power quality data captured as soon as users      begin sessions, without extensive setup or selectionsIntuitive user interface streamlined to makes it easy      to navigate between measurement parameters like V/A/Hz, power, dips and      swells, harmonics, or power quality health, with single push of buttonHigh-speed voltage transient captures damaging      high-speed transients so users can mitigate their effects before equipment      failsAnalysis and reporting comes standard with Fluke Energy      Analyze Plus software, giving users ability to create customized reports,      or leverage built-in one-click reporting to industry standards, like EN      50160, IEEE 519 and GOST 33073Energy studies: Get detailed power and energy      consumption profiles during energy audits and pinpoint savings      opportunitiesBasic harmonics study: Discover source of distortion in      user installation, to filter loads or move them to separate circuitsAdvanced harmonics study: If distorting loads are      causing problems during installation, users need comprehensive data to      identify source in order to create solutionsBasic industrial PQ troubleshooting: When      troubleshooting in field, graphical data enables users to trace source of      problems at handAdvanced PQ troubleshooting: Complex installations      often require deeper dive into measurement data; multiple loads may be      interacting randomly to cause single problemInrush: Discover peak current from load switchingFlicker: Measure effects of disturbing switching      equipmentTransients: Capture high speed voltage waveform caused      by switching or network disturbancesMains signaling: Monitor signals on the network that      are used for network wide equipment controlEvent waveform capture: Visualization of dips and      swells to identify cause of the eventsInterfaces:
    
        USBEthernetWi-FiBluetoothWireless downloadSafety: 600 V/CAT IV; 1000 V/CAT III; Power from      measurement line Applications      
    Energy surveys and load testingHarmonic surveysNuisance circuit breaker trippingPower utility power quality surveysDiscovery of equipment failures caused by transients Each Unit Includes
    1 - 1775 Three-Phase Power Quality Analyzer1 - Flat Cable, Voltage Test Lead, 3-PHASE+N4 - AC285, Black Alligator Clips1 - AC285, Green Alligator Clip1 - Black USB-C Cable, 1m1 - Line Cord1 - Test Lead Set, Nonstack/Stack, 0.18m1 - Green Test Lead1 - Magnet Probe, 3 Red / 1 Black Magnet Probes for 4mm Banana1 - Hanger Kit1 - WIFI/BLE Module1 - Colored Cable Marker Set for Voltage and Current1 - Wall Outlet Adapter1 - Certificate of Calibration1 - Soft Carrying Case (Black) 
                          
    
        
            | Voltage inputs |  
            | Number of inputs | 4 inputs, 3 phases and neutral referenced to PE (5 connectors) |  
            | Measurement category | 1000 V CAT III / 600 V CAT IV |  
            | Maximum input voltage | 1000 V rms / 1000 V dc (1700 Vpk) Nominal voltage range Wye and single phase: variable (50 V - 1000 V) Delta: Variable (100 V - 1000 V)
 IEC 61000-4-30 Class A compliance for the nominal voltages (Vdin) 100 V - 690 V
 |  
            | Input impedance | 10 MΩ between P-P and P-N, 5 MΩ between P-PE and N-PE |  
            | Bandwidth | DC to 30 kHz for PQ measurements, excluding transients |  
            | Resolution | 24-bit synchronous sampling |  
            | Sampling frequency | 80 kS/s at 50/60 Hz |  
            | Scaling | 1:1, variable for use of potential transformers |  
            | Voltage transients |  
            | Measurement range | ±8 kV |  
            | Sampling rate | 1775: 1 MS/s |  
            | 1777: 1 MS/s, 20 MS/s |  
            | Bandwidth | DC to 1 MHz |  
            | Trigger | Adjustable trigger level. Triggers on high-frequency components > 1.5 kHz |  
            | Resolution | 14-bit synchronous sampling |  
            | Current inputs |  
            | Number of inputs | 4 inputs 3 phases and Neutral, range selected automatically to attached sensor |  
            | Range | AC | 1 A to 1500 A with i17XX-FLEX1500 12 1 A to 1500 A with i17XX-FLEX1500 24
 3 A to 3000 A with i17XX-FLEX3000 24
 6 A to 6000 A with i17XX-FLEX6000 36
 40 mA to 40 A with clamp i40s-EL
 4 A to 400 A with clamp i400s-EL
 |  
            | DC | 20 A to 2000 A with 80i-2010-EL clamp |  
            | Bandwidth | DC to 30 kHz |  
            | Resolution | 24-bit synchronous sampling |  
            | Sampling frequency | 80 kS/s at 50/60 Hz |  
            | Scaling | 1:1, variable |  
            | Input voltage | Clamp: 50 mV / 500 mV rms; CF 2.8 Rogowski Coil: 15 mV / 150 mV rms at 50 Hz, 18 mV / 180 mV rms at 60 Hz
 CF 4 all at nominal probe range
 |  
            | Input impedance | 11 kΩ |  
            | Standard compliance |  
            | Power | IEEE 1459 |  
            | Harmonics | IEC 61000-4-7: Class 1 IEEE 519 (short time and very short time harmonics)
 |  
            | Flicker | IEC 61000-4-15 Class F1 |  
            | Power quality | IEC 61000-4-30 Class A, IEC 62586 PQI-A-PI |  
            | Power quality compliance | EN 50160 + GOST + NEQUAL + NETCODE + FOL |  
            | Interfaces |  
            | Ethernet | 1 Gbit/s 1000BASE-T |  
            | USB type A | USB 2.0 high speed for USB flash drives to transfer measurement data, firmware updates and license installation. Max. supply current: 500 mA |  
            | USB-C | USB 2.0 high speed for data download to PC and calibration (requires USB type A to USB-C or USB-C to USB-C cable) Auxiliary power supply for the Analyzer (requires USB C power adapter PD 2.0 or higher with 9 V 1.8 A support)
 USB 3.0 super-speed for USB-C flash drives to transfer measurement data, firmware updates and license installation. Max. supply current: 900 mA
 |  
            | WiFi/BLE module1 | 802.11 ac 2.4 GHz / 5 GHz, support for concurrent access point and client mode Bluetooth 5.0/BLE
 Antenna: Internal and external2
 |  
            | LTE/4G module3 | LTE-A Cat 12 Worldwide LTE-A and UMTS/HSPA+ coverage
 Antenna: External2
 |  
            | GPS | MCX connector to attach a GNSS antenna for GPS/GLONASS2 |  
            | 
                Not in 177X/BASIC versionsRequires 5m extension cable, Fluke p/n 5263915Availability and supported providers vary by country. Check with your local Fluke representative |    
    
        
            | Power Measurement/Power Quality Analyzer Template |  
            | Type (Power Quality) | 3 Phase |  
            | Maximum Current AC | 6000 A |  
            | Maximum Current DC | 2000 A |  
            | True Power / Work ( W) | Yes |  
            | Apparent Power (VA) | Yes |  
            | Reactive Power (VAR) | Yes |  
            | Current Input Channels | 4 |  
            | Voltage Input Channels | 4 |  
            | Measurement Frequency (Power Quality) | 50 Hz, 60 Hz |  
            | Display (Power Quality) | Digital |  
            | Transient Capture | Yes |  
            | Displays Waveform | Yes |  
            | Energy | Yes |  
            | Phasor Diagrams | No |  
            | Harmonics | Yes |  
            | Maximum Harmonics Range | 50 |  
            | Class A Compliant | Yes |  
            | Crest Factor | No |  
            | CAT Rating | IV |  
            | CAT Voltage Rating (V) | 600V |  
            | GPS Location | Yes |  
         
            | Warranty | 2 YEARS |  
            | Interfaces I/O | LAN / Ethernet, Wifi, USB, USB-C, WWAN |  
            | Storage | Internal Memory, Micro SD |  
            | IP Rating | IP50 |  
            | Product Weight | 4.6 LBS |  
            | Product Height | 2.4 IN |  
            | Product Length | 11 IN |  
            | Product Width | 7.5 IN |  
            | Data Logging | Yes |  
            | Battery Type | Li-ion |  |  
					
                
        
        
              Accessories
            
            
                
                        
                            | Product | Price |  
                            |  | Fluke 177X LI-ION BATTERY 
                                    Catalog #: 5272862
Li-Ion Battery for 177X Series Units, 3.56V, 4000 mAh | $142.24
 
 |  
                            |  | Fluke C1777 HARD CASE 
                                    Catalog #: 5307460
IP67 Rated Hard Carrying Case with Wheels for 1777 Units | $1,012.24
 
 |  
                            |  | Fluke C177X 
                                    Catalog #: 5307472
Soft Carrying Case for 177X Series and NORMA 6000 Series Units (Black) | $416.24
 
 |  
                            |  | Fluke I17XX-FLEX1500 24 
                                    Catalog #: 5171005