				Fluke Networks OFP2-100-M
                
                
                
 			 
				Catalog #: 4955194
OptiFiber Pro Multi-mode OTDR Kit, 850/1300 nm, Wi-Fi Adapter
 
 
                
                    OverviewSpecificationsSummaryAccessories 	
                    
				        
                        Product Highlights
    Includes Multi-mode      OTDR Modules and a WiFi adapter that makes it easy to connect the Versiv 2      Mainframe to Linkware Live
SmartLoop OTDR      enables automated testing and analysis of two fibers in a single test,      eliminating the need to travel to the far end of the connection to perform      tests.
Taptive user      interface puts advanced data analysis and easy set-up and operation at the      fingertips of of technicians of all skill levels.
Linkware Live      enables to easily track job progress, get real-time access to test results      to quickly fix problems in the field, and easily transfer and consolidate      test results from the tester to LinkWare PC Cable Test Management      Software.
 Performance:
    Test times as short      as two seconds in Quick Test mode
Quickly test      datacenter fiber with pre-programmed settings
Troubleshoot      datacenter fiber links with short patch cables and many connectors because      of ultra short dead zones
Easily characterize      all connectors, splices and areas of high loss with graphical EventMap      view
Pass/Fail      certification of fiber optic connector endfaces
ProjX management      system increases return on investment by enabling OTDR
Reduce network      downtime by quickly and precisely identifying faults on all fiber types
Built-in Visual      Fault Locator (VFL) easily identifies damaged fibers.
 Standards:         
    Full OTDR      capability that certifies fiber performance based on industry standards or      customer specifications
Complaint with ISO      and TIA standards Each Unit Includes
    1 - Versiv 2 Mainframe1 - OptiFiber Pro Multimode OTDR module1 - Shoulder Strap1 - USB Interface Cable1 - Versiv 2 Open Source Software CD1 - AC Charger1 - WiFi Adapter for Versiv 2 Mainframe1 - Statement of Calibration and Getting Started Guides 
                          
    
        
            | Key OTDR specifications |  
            |  | Multimode module | Singlemode module | Quad module |  
            | Wavelengths | 850 nm +/- 10 nm 1300 nm +35/-15 nm
 | 1310 nm +/- 25 nm 1550 nm +/- 30 nm
 | 850 nm +/- 10 nm 1300 nm +35/-15 nm
 1310 nm +/- 25 nm
 1550 nm +/- 30 nm
 |  
            | Compatible fiber types | 50/125 µm 62.5/125 µm
 | Singlemode | 50/125 µm 62.5/125 µm
 Singlemode
 |  
            | Event dead zone 1 | 850 nm: 0.5 m typical 1300 nm: 0.7 m typical
 | 1310 nm: 0.6 m typical 1550 nm: 0.6 m typical
 | 850 nm: 0.5 m typical 1300 nm: 0.7 m typical
 1310 nm: 0.6 m typical
 1550 nm: 0.6 m typical
 |  
            | Attenuation dead zone 2 | 850 nm: 2.5 m typical 1300 nm: 4.5 m typical
 | 1310 nm: 3.6 m typical 1550 nm: 3.7 m typical
 | 850 nm: 2.5 m typical 1300 nm: 4.5 m typical
 1310 nm: 3.6 m typical
 1550 nm: 3.7 m typical
 |  
            | Dynamic range 3, 5, 6 | 850 nm: 28 dB typical 1300 nm: 30 dB typical
 | 1310 nm: 32 dB typical 1550 nm: 30 dB typical
 | 850 nm: 28 dB typical 1300 nm: 30 dB typical
 1310 nm: 32 dB typical
 1550 nm: 30 dB typical
 |  
            | Max distance range setting | 40 km | 130 km | MM: 40 km SM: 130 km
 |  
            | Distance measurement range 4, 5, 7, 8, 9, 10 | 850 nm: 9 km 1300 nm: 35 km
 | 1310 nm: 80 km 1550 nm: 130 km
 | 850 nm: 9 km 1300 nm: 35 km
 1310 nm: 80 km
 1550 nm: 130 km
 |  
            | Reflectance range 4, 5 | 850 nm: -14 dB to -57 dB (typical) 1300 nm: -14 dB to -62 dB (typical)
 | 1310 nm: -14 dB to -65 dB (typical) 1550 nm: -14 dB to -65 dB (typical)
 | 850 nm: -14 dB to -57 dB (typical) 1300 nm: -14 dB to -62 dB (typical)
 1310 nm: -14 dB to -65dB (typical)
 1550 nm: -14 dB to -65 dB (typical)
 |  
            | Sample resolution | 3 cm to 400 cm | 3 cm to 400 cm | 3 cm to 400 cm |  
            | Pulse widths (nominal) | 850 nm: 3, 5, 20, 40, 200 ns 1300 nm: 3, 5, 20, 40, 200, 1000 ns
 | 1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns | 850 nm: 3, 5, 20, 40, 200 ns 1300 nm: 3, 5, 20, 40, 200, 1000 ns
 1310/1550 nm: 3, 10, 30, 100, 300, 1000, 3000, 10000, 20000 ns
 |  
            | Test time (per wavelength) | Auto setting: 5 sec (typical) | Auto setting: 10 sec (typical) | Auto setting: MM - 5 sec (typical)
 SM - 10 sec (typical)
 |  
            | Quick test setting: 2 sec (typical)
 | Quick test setting: 5 sec (typical)
 | Quick test setting: MM - 2 sec (typical)
 SM - 5 sec (typical)
 |  
            | Best resolution setting: 2 to 180 sec
 | Best resolution setting: 5 to 180 sec
 | Best resolution setting: MM - 2 to 180 sec M
 SM - 5 to 180 sec
 |  
            | FaultMap setting: 2 sec (typical), 180 sec (max)
 | FaultMap setting: 10 sec (typical), 180 sec (max)
 | FaultMap setting: MM - 2 sec (typical), MM - 180 sec (max)
 SM - 10 sec (typical), SM - 180 sec (max)
 |  
            | DataCenter OTDR setting: 1 sec (typical at 850 nm), 7 sec (max)
 | DataCenter OTDR setting: 20 sec (typical), 40 sec (max)
 | DataCenter OTDR setting: MM - 1 sec (typical at 850 nm) MM - 7 sec (max)
 SM - 20 sec (typical) SM - 40 sec (max)
 |  
            | Manual setting: 3, 5, 10, 20, 40, 60, 90, 120, 180 sec
 | Manual setting: 3, 5, 10, 20, 40, 60, 90, 120, 180 sec
 | Manual setting: -3, 5, 10, 20, 40, 60, 90, 120, 180 sec SM - 3, 5, 10, 20, 40, 60, 90, 120, 180 sec
 |  
    Measured at 1.5 dB below non-saturating reflection peak with the shortest pulse width. Reflection peak < -40 dB for multimode and < - 50 dB for singlemode.Measured at +/- 0.5 dB deviation from backscatter with the shortest pulse width. Reflection peak < -40 dB for multimode and < - 50 dB for singlemode.For typical backscatter coefficient for OM1 fiber: 850: -65 dB, 1300: -72 dB.Typical backscatter and attenuation coefficients for OM2-OM4 fiber: 850 nm: -68 dB; 2.3 dB/km: 1300 nm: -76 dB; 0.6 dB/km.Typical backscatter and attenuation coefficients for OS1-OS2 fiber: 1310nm : -79 dB; 0.32 dB/km; 1550 nm: -82 dB; 0.19 dB/km.SNR = 1 method, 3 minute averaging, widest pulse width.850 = 9 km typical to find the end or 7 km typical to find a 0.1 dB event (with a maximum of 18 dB attenuation prior to the event).1300 = 35 km typical to find the end or 30 km typical to find a 0.1 dB event (with a maximum of 18 dB attenuation prior to the event).1310 = 80 km typical to find the end or 60km typical to find a 0.1 dB event (with a maximum of 20 dB attenuation prior to the event).1550 = 130 km typical to find the end or 90 km typical to find a 0.1 dB event (with a maximum of 18 dB attenuation prior to the event).Does not include index of refraction error and does not include automatic event location error.dB variation per 1 dB step.Applies along the trace backscatter within the distance range in which the OTDR can find a 0.1 dB event.   
    
        
            | Product Height | 9.00 IN |  
            | Product Length | 17.00 IN |  
            | Product Width | 11.00 IN |  
            | Country of Origin | United States |  
            | Shipping Height | 9.00 IN |  
            | Shipping Length | 17.00 IN |  
            | Shipping Width | 11.00 IN |  |  
				 |  
     |  |