| General Specification | 
        
            | Color alarms (temperature alarms) | High temperature, low temperature, and isotherms (within range) | 
        
            | Infrared spectral band | 8 μm to 14 μm (long wave) | 
        
            | Operating Temperature | -10 °C to +50 °C (14 °F to 122 °F) | 
        
            | Storage Temperature | -40 °C to +70 °C (-40 °F to 158 °F) | 
        
            | Relative humidity | 95 % non-condensing | 
        
            | Center-point temperature | Yes | 
        
            | Spot temperature | Hot and cold spot markers | 
        
            | Safety | EN 61010-1: CAT none, pollution degree 2, EN 60825-1: Class 2, EN 60529, EN 62133 (lithium battery) | 
        
            | Electromagnetic compatibility | EN301 489-1 V2.1.1 EN301489-17 V3.1.1 | 
        
            | US FCC | CFR, Part 15C | 
        
            | Vibration and shock | 2G, IEC 68-2-6 and 25G, IEC 68-2-29 | 
        
            | Drop | 1 meter | 
        
            | Size (H x W x L) | 8.9cm x 12.7cm x 2.5cm (3.5 in x 5.0 in x 1.0 in) | 
        
            | Weight | 0.233 kg (0.514 lb) | 
        
            | Enclosure rating | IP54 | 
        
            | Warranty | Two-years | 
        
            | Supported languages | Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish | 
        
            | IFOV (spatial resolution) | 7.6 mRad | 
        
            | Infrared resolution | 120 x 90 (10,800pixels) | 
        
            | Field of view | 50° H x 38° V | 
        
            | Distance to spot | 130:1 | 
        
            | Temperature measurement range(not calibrated below -10 °C) | -20 ° C to 150 ° C | 
        
            | Focus system | Fixed focus, minimum focus distance 22.8 cm | 
        
            | USB | Mini USB used to transfer image to PC | 
        
            | Wifi | Yes | 
        
            | Fluke Connect® Instant Upload | Yes, connect your camera to your building’s WiFi network, and images taken automatically upload to the Fluke Connect® system or your local server for storage and viewing on your PC (802.11 bgn (2.4 GHz)) | 
        
            | Image quality | 
        
            | IR-Fusion technology | Yes, adds the context of the visible details to your infrared image | 
        
            | AutoBlend mode | Continuous 0% to 100% | 
        
            | Touchscreen display | 3.5" (landscape), 320 x 240 LCD | 
        
            | Rugged, ergonomic design | Yes | 
        
            | Thermal sensitivity (NETD) | 60 mK | 
        
            | Frame rate | 9 Hz | 
        
            | Data storage and image capture | 
        
            | Memory | ≥2 GB internal flash memory | 
        
            | Image capture, review, save mechanism | One-handed image capture, review, and save capability | 
        
            | Image file formats | Non-radiometric (jpeg), or fully radiometric (.is2); no analysis software required for non-radiometric (jpeg) files | 
        
            | Software | Fluke Connect® desktop software—full analysis and reporting software with access to the Fluke Connect system | 
        
            | Export file formats with software | JPG, IS2 | 
        
            | Measurement Range | -20 °C~150 °C | 
        
            | Battery | 
        
            | Batteries (rechargable) | Internal rechargeable lithium ion battery. | 
        
            | Battery life | ≥ 2 hours continuous (without WiFi) | 
        
            | Battery charging time | ≤ 1.5 hours | 
        
            | Battery charging system | Micro USB cord from product to PC | 
        
            | AC operation | With separate AC to USB adapter. Not included in box | 
        
            | Power saving | Automatic Shutdown: 5, 10, 15 and 20 minutes or never
 | 
        
            | Temperature measurement | 
        
            | Temperature measurement range (not calibrated below -10 °C) | -20 ° C to 150 ° C | 
        
            | Accuracy | Target temp at or over 0 °C: Accuracy: ± 2° C or ± 2 % | 
        
            | On-screen emissivity correction | Yes | 
        
            | On-screen reflected background temperature compensation | Yes | 
        
            | Color palettes | Standard palettes 6: Ironbow, Blue-Red, High Contrast, Amber, Hot Metal, Grayscale |