				Fluke I430-FLX-TFII-48
                
                
                
 			 
				Catalog #: 4621231
6000 A Flexible AC Current Probe 122cm (48 inch)
 
 
                
                    OverviewSpecificationsSummary 	
                    
				        
                        Product Highlights 
    6000 A Flexible AC Current Probe 122cm (48 inch)For use with the Fluke 430 series I and II Power Quality Analyzers and other dedicated test tools.Optimized for current measurement on thick and hard to reach conductors. 
                          
    
        
            | General Specifications |  
            |  | i430-Flexi- |  
            |  | TF-II | TF-II-48 |  
            | Transducer length | 61 cm (24 in) | 122 cm (48 in) |  
            | Weight | 153 g | 200 g |  
            | Transducer diameter | 7.5 mm (0.3 in) |  
            | Minimum bending radius | 38 mm (1.5 in) |  
            | Cable length from transducer to BNC | 2.5 m (98.4 in) |  
            | Temperature, operating | -20 °C to +70 °C (-4 °F to +158 °F) Temperature of conductor under test shall not exceed 80 °C (176 °F)
 |  
            | Temperature, non-operating | -40°C to + 80 °C (-40 °F to +176 °F) |  
            | Relative Humidity, operating | 15 % to 85 %, noncondensing |  
            | Altitude, operating | 2 000 m (6 500 ft); for use up to 4000 moderate to 300 V CAT IV, 600 V CAT III, 1000 V CAT II. |  
            | Altitude, storage | 12 km (40 000 ft) |  
            | Ingress protection | IP40 |  
            | Specifications |  
            | SAFETY W | The i430-Flexi-TF-II complies with: • IEC 61010-1: Pollution degree 2
 • IEC 61010-2-032: CAT IV 600 V / CAT III 1000 V
 |  
            | Electrical Specifications |  
            | Measuring range | 0.5 A ac to 6000 A ac |  
            | Maximum non-destructive current | 100 kA (50/60 Hz) |  
            | Output signal | 86.6 mV at 1000 A/50 Hz (on 1 MΩ) 85.0 mV at 1000 A/50 Hz (on 50 kΩ)
 |  
            | Basic accuracy | ±1 % of reading at 25 °C, 50 Hz with conductor placed at the center of the probe |  
            | Linearity | ±0.2 % of reading at 10 % to 100 % of range |  
            | Noise | <1 mV rms at 10 Hz to 10 kHz |  
            | Additional errors 
                temperature coefficient over operating temperature range-for 24 inch model
 -for 48 inch model
 
with position of conductor in the probe window (see Figure 1):Zone A
 Zone B
 Zone C
 
0.5 to 30 A | 0.02 % of reading / °C (0.011 % / °F)
 0.035 % of reading / °C (0.02 % / °F)
 
 
 
 
 
 
 ±0.5 % of reading
 ±1.0 % of reading
 ±2.0 % of reading
 ±1 count or 0.1 A (whichever is greater)
 |  
            | External magnetic field rejection in reference to external current | 40 dB (with cable >100 mm from the head coupling and r-coil) |  
            | Phase shift (fundamental frequency) | <±1° |  
            | Bandwidth (-3 dB) | 10 Hz to 10 kHz |  
            | Frequency derating | I x f ≤385 kA Hz |    
    
        
         
            | Country of Origin | Bulgaria |  |  
					
				 
					
				 
				 |  
     
    
    
        