				FLIR DM285-FLEX-KIT
                
                
                
 			 
				Catalog #: DM285-FLEX-KIT
FLIR Professional Imaging Multimeter Kit
 
 
                
                    OverviewSpecificationsSummaryCurrent ClampsAccessories 	
                    
				        
                        Product Highlights Work Safer and Smarter 
    Identify energized and faulty equipment from a safe distance with non-contact temperature measurementStreamline inspections and simplify data collection, sharing, and reporting by wirelessly connecting to the FLIR InSite professional workflow management tool*Save electrical parameter data and thermal images with onboard data storage* Troubleshoot Challenging Problems Effectively 
    Solve challenging problems with the 18-function DMM including VFD mode, True RMS, LoZ, NCV, a built-in worklight, and laser pointerMeasure voltage, current, frequency, resistance, continuity, diode, capacitance, and temperatureOperate easily with an intuitive menu system Design and Functionality 
    Rely on the meters' drop-tested durability in any working conditionChange the battery quickly and easily with the 'no tool' battery compartment*See readings clearly on the TFT display with a wide viewing angle* Features for FLIR TA10-F 
    TA10-F Protective caseFor DM9x and TA72/74 or CM55/57Form-fitting instrument compartmentConcealed zipper resists dirtResilient nylon carry strapRugged, non-slip finish Features for FLIR TA74 
    Take accurate measurements in tight or awkward spotsSnake the coil around obstacles with ease, even in deep, crowded cabinetsMeasure multiple conductors and targets with limited clearanceSwitchable AC current range – 30A, 300A, 3000ACompatible with most DMMs and clamp meters, regardless of brandAdds 3000A AC current measurements to existing metersStandard banana plug connectors fit most metersAC voltage output for wide compatibilityBright, dual LED worklights provide built-in illumination for dark cabinetsRugged design drop-tested to 3 meters, portable and lightweight Each Unit Includes 
    FLIR DM285 True RMS Digital MultimeterProtective Carrying Case (TA74)Universal Flex Current Probe (TA10-F) 
                          
    
        
            | FLIR DM285 Specifications |  
            | IR Resolution | 160 x 120 (19,200 pixels) |  
            | Temperature Sensitivity | 150mK |  
            | Temperature Accuracy | 3°C or 3% |  
            | Temperature Range | 14 to 302°F (-10 to 150°C) |  
            | Field of View | 50.0° x 38° |  
            | Focus | Fixed |  
            | Thermal Imaging Palette | Iron, Rainbow, Grayscale |  
            | Continuity Check | 20Ω and 200Ω |  
            | Data Logging & Storage | 10 sets of 40K scalar measurements, 100 images |  
            | Electrical Specifications |  
            | AC/DC Volts | Range: 1000V |  
            | Accuracy: ±1.0%/0.09% |  
            | AC/DC mVolts | Range: 600.0mV |  
            | Accuracy: ±1.0%/0.5% |  
            | AC/DC Amps | Range: 10.00A |  
            | Accuracy: ±1.5%/1.0% |  
            | AC/DC mAmps | Range: 400.0mA |  
            | Accuracy: ±1.5%/1.0% |  
    
        
            | Specification For | TA72 | TA74 |  
            | Maximum AC current | 3000A |  
            | AC current ranges and resolution
 | 30.00A, 300.0A, 3000A |  
            | Basic AC current accuracy (full scale)
 | ± 3.0% + 5 digits |  
            | Measurement rate | 1.5 samples per second, nominal |  
            | AC current bandwidth | 45Hz – 500Hz (sine wave) |  
            | Positional error (distance from optimum)
 | 0.6" (15mm) ± 2.0% 1.0" (25mm) ± 2.5%
 1.4" (35mm) ± 3.0%
 | 1.4" (35mm) ± 1.0% 2.0" (50mm) ± 1.5%
 2.4" (60mm) ± 2.0%
 |  
            | Meter Data |  
            | Minimum requirements for meter compatibility with TA72
 | AC voltage function, 4000 count display 1mV remote* |  
            | Max conductor diameter | 2.4" (6cm) | 4.7" (12cm) |  
            | Flex coil length | 10" (25cm) | 18" (45cm) |  
            | Flex coil diameter | 0.3" (7.5mm) |  
            | Flex coil tip diameter | 0.5" (13mm) |  
            | Cable length | 73" (1.9m) |  
            | Worklight | Two white LEDs |  
            | Power supply | (2) 1.5V “AAA” |  
            | Drop test | 9.8' (3m) |  
            | Agency approvals | CE, UL |  
            | Safety rating | CAT IV 600V, CAT III 1000V |  
            | Standards | EN61010-1, EN61010-2-032, EN61326-1 |  
            | Warranty | Limited lifetime with registration** |    
    
        
            | Multimeters Template |  
            | Type | Digital |  
            | Style | Hand-Held |  
            | Measures AC V | Yes |  
            | Measures DC V | Yes |  
            | Measures AC A | Yes |  
            | Measures DC A | Yes |  
            | True RMS | Yes |  
            | Maximum Voltage AC | 1000 V |  
            | Maximum Voltage DC | 1000 V |  
            | Maximum Current AC | 3000 A |  
            | Maximum Current DC | 10 A |  
            | Basic Accuracy V DC | 0.09% |  
            | Manual/Autoranging | Auto-ranging |  
            | Dual Display | Yes |  
            | Resistance | Yes |  
            | Frequency | Yes |  
            | Continuity | Yes |  
            | Capacitance | Yes |  
            | Temperature | Yes |  
            | Diode Testing | Yes |  
            | CAT Rating | IV |  
            | CAT Voltage | 600 V |  
            | Kelvin 4-Wire Measurement Capability | No |  
            | Data Hold | Yes |  
            | Low-Pass Filter | Yes |  
            | Thermal Imagers/Building and Industrial Thermal Imagers Template |  
            | Detector Size | 160 x 120 Sensor |  
            | Thermal Sensitivity | 150 mK (NETD) |  
            | Temperature Range Max | 302 F |  
            | Temperature Range Min | 14 F |  
            | Image Frequency | 9 Hz |  
            | Field of View | 46x35 Degrees |  
            | Screen Size | 2.8 IN |  
            | IR/Overlay Fusion Image | No |  
            | Video Output | No |  
            | Focus | Fixed |  
            | Laser Spot | Yes |  
            | Picture in Picture | No |  
            | Video Recording | No |  
            | Moveable Spots | No |  
            | Touch Screen Display | No |  
            | Accuracy | 3°C or 3.5% |  
            | Battery operating time Continuous | 3 HR |  
            | Camera Light | Yes |  
            | IR Digital Zoom | No |  
            | Voice Annotation | No |  
         
            | Unique Features | Infrared Guided Measurement (IGM) powered by 160x120 thermal sensor Adjustable emissivity for more accurate temperature readings
 18-function DMM including VFD mode, True RMS, LoZ, and NCV
 Features bright worklights and laser pointer
 Multiple color palettes
 Premium test leads included
 Built-in non-contact voltage detector
 Bluetooth
 Thermal temperature to 302°F
 Type-K Thermocouple -40°F to 752°F
 Data logging: 3 samples/S
 |  
            | Warranty | 10 YEARS |  
            | Warranty Details | 10 year on product and detector |  
            | Calibration Included | None |  
            | Power Supply Voltage | Battery Powered |  
            | Data Logging | Yes |  
            | Interfaces I/O | Bluetooth |  
            | Storage | Internal Memory |  
            | IP Rating | IP40 |  
            | Product Weight | 18.9 OUNCES (1.18 LBS) |  
            | Battery Type | AA |  
            | Country of Origin | Taiwan |  |  
					
                
        
        
              Current Clamps