				Fluke 3540 FC KIT
                
                
                
 			 
				Catalog #: 4948724
3-Phase Power Monitor
 
 
                
                    OverviewSpecificationsSummaryCurrent ClampsAccessories 	
                    
				        
                        Product Highlights 
    THREE-PHASE MONITORING AND STREAMING
    
        Monitor three-phase systems and stream data to the Fluke Connect CloudCONNECTED
    
        The measurement data from the Fluke Connect Cloud is available on any connected device using the Fluke Connect mobile app or Fluke Connect Condition Monitoring softwareEASY-TO-INSTALL AND MOVE
    
        Powered from the measurement circuit, configuration checker can automatically correct connection errorsALWAYS ON
    
        The Monitor includes a mode to log measurements when no connection to the Fluke Connect Cloud is available Each Unit Includes 
    Power supplyVoltage test leads(4x) Dolphin clips(3x) 1500A flexible current probeMagnetic hanging kitWiFi to USB adapterColor coding set 
                          
    
        
            | General Specifications |  
            | Color LCD display | 4.3-inch active matrix color TFT, 480 pixels x 272 pixels, resistive touch panel |  
            | Warranty | 3540 FC and built-in power supply | 2 years (battery not included) |  
            | Accessories | 1 year |  
            | Calibration cycle | 2 years |  
            | Dimensions (W x H x D)
 | 3540 FC | 19.8 cm x 16.7 cm x 5.5 cm (7.8 in x 6.6 in x 2.2 in) |  
            | Detachable power supply | 13.0 cm x 13.0 cm x 4.5 cm (5.1 in x 5.1 in x 1.8 in) |  
            | 3540 FC with power supply attached | 19.8 cm x 16.7 cm x 9 cm (7.8 in x 6.6 in x 4.0 in) |  
            | Weight | 3540 FC | 1.1kg (2.5 lb) |  
            | Power Supply | 400 g (0.9 lb) |  
            | Tamper protection | Kensington lock |    
    
        
            | Environmental Specifications |  
            | Operating temperature | <10 °C to +45 °C (+14 °F to +113 °F) |  
            | Storage temperature | <20 °C to +60 °C (-4 °F to +140 °F), with battery: -20 °C to +50 °C (-4 °F to +122 °F) |  
            | Operating humidity | <10 °C (<50 °F) non condensing |  
            | 10 °C to 30 °C (50 °F to 86 °F) ≤95 % |  
            | 30 °C to 40 °C (86 °F to 104 °F) ≤75 % |  
            | 40 °C to 45 °C (104 °F to 113 °F) ≤45 % |  
            | Operating altitude | 2000 m (6,500 ft) (up to 4,000 m derate to 1000 V CAT II/600 V CAT III/300 V CAT IV) |  
            | Storage altitude | 12,000 m (39,000 ft) |  
            | IP rating | IEC 60529:IP50, in connected condition with protection caps in place |  
            | Vibration | MIL-T-28800E, Type 3, Class III, Style B |  
            | Safety |  
            | IEC 61010-1 | IEC mains input | Overvoltage Category II, Pollution Degree 2 |  
            | Voltage terminals | Overvoltage Category IV, Pollution Degree 2 |  
            | IEC 61010-2-033 | CAT IV 600 V / CAT III 1000 V |  
            | Electromagnetic compatibility (EMC) |  
            | International | IEC 61326-1: Industrial |  
            | Korea (KCC) | Class A Equipment (Industrial Broadcasting & Communication Equipment) |  
            | USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. |  
            | Wireless radio with adapter |  
            | Frequency range | 2412 MHz to 2462 MHz |  
            | Output power | <100 mW |    
    
        
            | Electrical specifications |  
            | Power supply |  
            | Voltage range | nominal 100 V to 500 V (85 V min to 550 V max) using safety plug input |  
            | Mains power | nominal 100 V to 240 V (85 V min to 265 V max) using IEC 60320 C7 input |  
            | Power consumption | Maximum 50 VA (max. 15 VA when powered using IEC 60320 input) |  
            | Standby Power | <0.3 W only when powered using IEC 60320 input |  
            | Efficiency | ≥ 68.2 % (in accordance with energy efficiency regulations) |  
            | Mains frequency | 50/60 Hz ± 15 % |  
            | Battery power | Li-ion 3.7 V, 9.25 Wh, customer-replaceable |  
            | On-battery runtime | Up to 4 hr (up to 5.5 hr in energy saving mode) |  
            | Charging time | <6 hr |  
            | Voltage inputs |  
            | Number of inputs | 4 (3 phases and neutral) |  
            | Maximum input voltage | 1000 Vrms (1700 Vpk) phase to neutral |  
            | Input impedance | 10 MΩ each phase to neutral |  
            | Bandwidth | 42.5 Hz to 3.5 kHz |  
            | Scaling | 1:1, variable |  
            | Current inputs |  
            | Number of inputs | 3, mode selected automatically for attached sensor |  
            | Current sensor output voltage | Clamp | 500 mVrms / 50 mVrms; CF 2.8 |  
            | Rogowski coil | 150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominal probe range |  
            | Bandwidth | (-3 dB) 42.5 Hz to 3.5 kHz |  
            | Scaling | 1:1 and variable |  
            | Data acquisition |  
            | Resolution | 16-bit synchronous sampling |  
            | Sampling frequency | 10.24 kHz at 50/60Hz, synchronized to mains frequency |  
            | Input signal frequency | 50/60 Hz (42.5 to 69 Hz) |  
            | Wiring configurations | 1-Φ, 1-Φ IT, Split phase, 3-Φ wye, 3-Φ wye IT, 3-Φ wye balanced, 3-Φ delta, 3-Φ Aron/Blondel (2-element delta), 3-Φ delta open leg, 3-Φ high leg delta, 3-Φ delta balanced. Currents only (load studies) |  
            | Data storage | Internal flash memory (not user replaceable) |  
            | Memory size | Typical 1 offline logging section of 1 week with 1 second intervals. The number of possible logging sessions and logging period depends on user requirements. |  
            | Basic interval |  
            | Measured parameters | Voltage, current, frequency, THD V, THD A, power, power factor, fundamental power, DPF |  
            | Averaging interval | 1 s |  
            | Total harmonic distortion | THD for voltage and current is calculated on 25 harmonics |  
            | Averaging time min/max values |  
            | Voltage | Full cycle RMS (20 ms at 50 Hz, 16.7 ms at 60 HZ) |  
            | Current | Half cycle RMS (10 ms at 50 Hz, 8.3 ms at 60 Hz) |  
            | Power | 200 ms |  
            | Interfaces |  
            | USB-A | Firmware updates, max. supply current: 120 mA |  
            | WiFi |  
            | Supported modes | Direct connection and connection to infrastructure |  
            | Security | WPA2-AES with pre-shared key |    
    
        
            | Power Measurement/Power Loggers Template |  
            | Input(power loggers) | Single Phase, Three Phase |  
            | Type(Power loggers) | Digital, Portable Hand Held |  
            | Maximum Current AC | 6000 A |  
            | Maximum Voltage AC | 1000 V |  
            | True RMS | Yes |  
            | Current Input Channels | 1, 2, 3 |  
            | Voltage Input Channels | 1, 2, 3, 4 |  
            | Measurement Frequency | 40 Hz, 50 Hz, 60 Hz, 70 Hz |  
            | Display (Energy Management) | Digital, Graphical |  
            | Displays Waveform | Yes |  
            | Energy | Yes |  
            | Power Factor (Power Quality) | Yes |  
            | Total Harmonic Distortion | Yes |  
            | Current Clamps Included | Yes |  
            | CAT Rating | III |  
            | CAT Voltage Rating (V) | 1000V, 600V |  
         
            | Warranty | 2 YEARS |  
            | Power Supply Voltage | Battery Powered |  
            | Data Logging | Yes |  
            | Interfaces I/O | Wifi |  
            | Storage | Internal Memory |  
            | Product Weight | 2.5 LBS |  
            | Battery Type | Li-ion |  
            | ECCN Number | 3A992 |  
            | HTS/Schedule B Number | 9030390100 |  
            | Country of Origin | Romania |  |  
					
				 
					
                
        
        
              Current Clamps
            
            
                
                        
                            | Product | Price |  
                            |  | Fluke I17XX-FLEX 6000/4PK 
                                    Catalog #: 4637430
iFlexi Current Clamp, 36 in. Circumference, 6000A, 4-Pack | $1,329.25
 
 |  
                            |  | Fluke i17XX-FLEX1500 
                                    Catalog #: 4637328
1500A 12 inch iFlex Current Clamp | $279.24
 
 |  
                            |  | Fluke I17XX-FLEX1500/3PK 
                                    Catalog #: 4637337
1500A 12 inch, 3 pack iFlex Current Clamp | $782.24
 
 |  
                            |  | Fluke I17XX-FLEX1500/4PK 
                                    Catalog #: 4637411
iFlexi Current Clamp, 12 in. Circumference, 1500A, 4-Pack | $1,051.24
 
 |  
                            |  | Fluke I17XX-FLEX3000 
                                    Catalog #: 4637343
3000A 24 inch iFlex Current Clamp | $317.24
 
 |  
                            |  | Fluke I17XX-FLEX3000/3PK 
                                    Catalog #: 4637355
3000A 24 inch, 3 pack iFlex Current Clamp | $782.24
 
 |  
                            |  | Fluke I17XX-FLEX3000/4PK 
                                    Catalog #: 4637427
iFlexi Current Clamp, 24 in. Circumference, 3000A, 4-Pack | $1,051.24
 
 |  
                            |  | Fluke I17XX-FLEX6000 
                                    Catalog #: 4637362
6000A 36 inch iFlex Current Clamp | $317.24
 
 |  
                            |  | Fluke I17XX-FLEX6000/3PK 
                                    Catalog #: 4637370
6000A 36 inch, 3 pack iFlex Current Clamp | $941.24
 
 |  
              Accessories 
				 |  
     |  |