				Fluke 1732/B
                
                
                
 			 
				Catalog #: 4706566
Three-Phase Electrical Energy Logger (Basic Version)
 
 
                
                    OverviewSpecificationsSummaryAccessoriesCurrent Clamps*Adapters 	
                    
				        
                        Product Highlights 
    Basic Version Three-Phase Electrical Energy Logger (excludes current probes)Energy studies: Full range of electrical power and energy parametersLoad studies: Simple current only logging for load sizingComprehensive logging: More than 20 separate logging sessions can be stored on the instrumentsOptimized user interface: Quick, guided, graphical setup ensures you’re capturing the right data every time, and the intelligent verification function indicates correct connections have been made, reducing user uncertaintyBright, color touch screen: Perform convenient in-the-field analysis and data checks with full graphical displayOptimized user interface: Capture the right data every time with quick, guided, graphical setup and reduce uncertainty about your connections with the intelligent verification functionComplete “in-the-field” setup through the front panel or Fluke Connect: No need to return to the workshop for download and setup or to take a computer to the electrical panelEnergy Analyze Plus application software: Download and analyze every detail of energy consumption with our automated reportingMeasure all three phases: With included 3 flexible current probesFully integrated logging: Connect other Fluke Connect devices to the Fluke 1732/1734 to simultaneously log up to two other measurement parameters, virtually any parameter available on a Fluke Connect wireless digital multimeter or module Each Unit Includes
    (1) Three-Phase Electrical Energy Logger (Basic Version)(1) Voltage Test Lead(1) Dolphin Clip (Black)(4) Color-coded Wire Clips(1) Power Cord(2) Red and Black Test lead with stackable plugs (10cm, 3.9in) Red and Black(2) Red and Black Test lead with stackable plugs (1.5m ,5ft)(1) DC Power Cable(1) USB Cable A (Mini-USB)(1) Soft Case(1) Input Connector Decal*(1) Documentation Info Pack     
    
        Quick Reference CardSafety InformationBattery Pack Safety InformationiFlex Probe Safety Informationi40s-EL Current Clamp Safety Information(1) 4GB USB Flash Drive (includes User’s Manual)ISO 9001 - Statement of Calibration Practices (W/Data) *The power cord and input connector decal are country-specific and vary according to the order destination 
                        
    
        
            | Accuracy |  
            | Parameter | Range | Max. Resolution | Intrinsic accuracy at reference conditions (% of reading + % of full scale)
 |  
            | Voltage: | 1000 V | 0.1 V | ± (0.2 % + 0.01 %) |  
            | Current: | i17xx-flex 1500 12” | 150 A 1500 A
 | 0.1 A 1 A
 | ± (1 % + 0.02 %) ± (1 % + 0.02 %)
 |  
            | i17xx-flex 3000 24” | 300 A 3000 A
 | 1 A 10 A
 | ± (1 % + 0.03 %) ± (1 % + 0.03 %)
 |  
            | i17xx-flex 6000 36” | 600 A 6000 A
 | 1 A 10 A
 | ± (1.5 % + 0.03 %) ± (1.5 % + 0.03 %)
 |  
            | i40s-EL clamp | 4 A 40 A
 | 1 mA 10 mA
 | ± (0.7 % + 0.02 %) ± (0.7 % + 0.02 %)
 |  
            | Frequency: | 42.5 Hz to 69 Hz | 0.01 Hz | ± (0.1 %) |  
            | Aux input: | ± 10 V dc | 0.1 mV | ± (0.2 % + 0.02 %) |  
            | Voltage min/max: | 1000 V | 0.1 V | ± (1 % + 0.1 %) |  
            | Current min/max: | defined by accessory | defined by accessory | ± (5 % + 0.2 %) |  
            | THD on voltage: | 1000% | 0.10% | ± 0.5 |  
            | THD on current: | 1000% | 0.10% | ± 0.5 |    
    
        
            | Intrinsic uncertainty ± (% of reading + % of range)1 |  
            | Parameter | Influence quantity | iFlex1500-12 150A/1500A
 | iFlex3000-24 300A/3000A
 | iFlex6000-36 600/6000A
 | i40s-EL 4A/40A
 |  
            | Active Power P Active Energy Ea
 | PF ≥ 0.99 | 1.2 % + 0.005 % | 1.2 % + 0.0075 % | 1.7 % + 0.0075 % | 1.2 % + 0.005 % |  
            | Apparent Power S Apparent Energy Eap
 | 0 ≤ PF ≤ 1 | 1.2 % + 0.005 % | 1.2 % + 0.0075 % | 1.7 % + 0.0075 % | 1.2 % + 0.005 % |  
            | Reactive Power Q Reactive Energy Er
 | 0 ≤ PF ≤ 1 | 2.5 % of measured apparent power |  
            | Additional uncertainty in % of range1 | V P-N   > 250 V | 0.015 % | 0.0225 % | 0.0225 % | 0.015 % |  1Range = 1000 V x IrangeReference conditions:
 •  Environmental: 23°C ± 5°C, instrument operating for at least 30 minutes, no external electrical/magnetic field, RH <65 %
 •  Input conditions: Cosϕ/PF=1, Sinusoidal signal f=50 Hz/60 Hz, power supply 120 V/230 V ±10 %.
 •  Current and power specifications: Input voltage 1 ph: 120 V/230 V or 3 ph wye/delta: 230 V/400 V Input current: I > 10 % of Irange
 •  Primary conductor of clamps or Rogowski coil in center position
 •  Temperature coefficient: Add 0.1 x specified accuracy for each degree C above 28°C or below 18°C
 
 
    
        
            | Electrical specifications |  
            | Power supply |  
            | Voltage range: | 100 V to 500 V using safety plug input when powering from the measurement circuit 100 V to 240 V using standard power cord (IEC 60320 C7)
 |  
            | Power consumption: | Maximum 50 VA (max. 15 VA when powered using IEC 60320 input) |  
            | Efficiency: | ≥ 68.2 % (in accordance with energy efficiency regulations) |  
            | Maximum no-load consumption: | < 0.3 W only when powered using IEC 60320 input |  
            | Mains power frequency: | 50/60 Hz ± 15 % |  
            | Battery: | Li-ion 3.7 V, 9.25 Wh, customer-replaceable |  
            | On-battery runtime: | Four hours in standard operating mode, up to 5.5 hours in power saving mode |  
            | Charging time: | < 6 hours |  
            | Data acquisition |  
            | Resolution: | 16-bit synchronous sampling |  
            | Sampling frequency: | 10.24 kHz at 50/60 Hz, synchronized to mains frequency |  
            | Input signal frequency: | 50/60 Hz (42.5 to 69 Hz) |  
            | Circuit types: | 1-ϕ, 1-ϕ IT, split phase, 3-ϕ delta, 3-ϕ wye, 3-ϕ wye IT, 3-ϕ wye balanced, 3-ϕ Aron/Blondel (2-element delta), 3-ϕ delta open leg, currents only (load studies) |  
            | Data storage: | Internal flash memory (not user replaceable) |  
            | Memory size: | Typical 10 logging sessions of 8 weeks with 1-minute intervals1 |  
            | Basic interval |  
            | Measured parameters: | Voltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental power, DPF, energy |  
            | Averaging interval: | User selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min |  
            | Averaging time min/max values: | Voltage, Current: Full cycle RMS updated every half cycle Aux, Power: 200ms |  
            | Demand Interval (Energy Meter Mode) |  
            | Measured parameters: | Energy (Wh, varh, VAh), PF, maximum demand, cost of energy |  
            | Interval: | User selectable: 5 min, 10 min, 15 min, 20 min, 30 min, off |  
            | Standards compliance |  
            | Power: | IEEE 1459 |  
            | Interfaces |  
            | USB-A: | File transfer via USB flash drive, firmware updates, max. supply current: 120 mA |  
            | WiFi: | File transfer and remote control via direct connection or WiFi infrastructure |  
            | Bluetooth: | Read auxiliary measurement data from Fluke Connect® 3000 series modules (requires 1734, or 1732 upgrade option) |  
            | USB-mini: | Data download device to PC |  
            | Voltage inputs |  
            | Number of inputs: | 4 (3 phases and neutral) |  
            | Maximum input voltage: | 1000 Vrms, CF 1.7 |  
            | Input impedance: | 10 MΩ |  
            | Bandwidth: | 42.5 Hz - 3.5 kHz |  
            | Scaling: | 1:1 and variable |  
            | Measurement category: | 1000 V CAT III/600 V CAT IV |  
            | Current inputs |  
            | Number of inputs: | 3, mode selected automatically for attached sensor |  
            | Input voltage: | Clamp input: 500 mVrms/50 mVrms; CF 2.8 |  
            | Rogowski coil input: | 150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominal probe range |  
            | Range: | 1 A to 150 A/10 A to 1500 A with thin flexible current probe i17XX-flex1500 12” 3 A to 300 A/30 A to 3000 A with thin flexible current probe i17XX-flex3000 24”
 6 A to 600 A/60 A to 6000 A with thin flexible current probe i17XX-flex6000 36”
 40 mA to 4 A/0.4 A to 40 A with 40 A clamp i40s-EL
 |  
            | Bandwidth: | 42.5 Hz - 3.5 kHz |  
            | Scaling: | 1:1 and variable |  
            | Auxiliary inputs |  
            | Number of inputs: | 2 |  
            | Input range: | 0 to ± 10 V dc, 1 reading/s |  
            | Scale factor: | Format: mx + b (gain and offset) user configurable |  
            | Displayed units: | User configurable (7 characters, for example, °C, psi, or m/s) |  
            | Wireless connection |  
            | Number of inputs: | 2 |  
            | Supported modules: | Fluke Connect ®  3000 series |  
            | Acquisition: | 1 reading/s |  
            | Environmental specifications |  
            | Operating temperature: | -10 °C to +50 °C (14 °F to 122 °F) |  
            | Storage temperature: | -20 °C to +60 °C (−4 °F to 140 °F), with battery: -20 °C to +50 °C (−4 °F to 122 °F) |  
            | Operating humidity: | 10 °C to 30 °C (50 °F to 86 °F) max. 95 % RH 30 °C to 40 °C (86 °F to 104 °F) max. 75 % RH
 40 °C to 50 °C (104 °F to 122 °F) max. 45 % RH
 |  
            | Operating altitude: | 2000 m (up to 4000 m derate to 1000 V CAT II/600 V CAT III/300 V CAT IV) |  
            | Storage altitude: | 12,000 m |  
            | Enclosure: | IP50 in accordance with EN60529 |  
            | Vibration: | MIL-T-28800E, Type 3, Class III, Style B |  
            | Safety: | IEC 61010-1 IEC Mains Input: Overvoltage Category II, Pollution Degree 2
 Voltage Terminals: Overvoltage Category IV, Pollution Degree 2
 IEC 61010-2-031: CAT IV 600 V/CAT III 1000 V
 |  
            | Electromagnetic compatibility (EMC): | EN 61326-1: Industrial CISPR 11: Group 1, Class A Korea (KCC): Class A Equipment (industrial broadcasting and communication equipment)
 USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103
 |  
            | Temperature coefficient: | 0.1 x accuracy specification/°C |  
            | General specifications |  
            | Color LCD display: | 4.3-inch active matrix TFT, 480 pixels x 272 pixels, resistive touch panel |  
            | Warranty: | Instrument and power supply: two-years (battery not included) Accessories: one-year
 Calibration cycle: two-years
 |  
            | Dimensions: | Instrument: 19.8 cm x 16.7 cm x 5.5 cm (7.8 in x 6.6 in x 2.2 in) Power supply: 13.0 cm x 13.0 cm x 4.5 cm (5.1 in x 5.1 in x 1.8 in)
 Instrument with power supply attached: 19.8 cm x 16.7 cm x 9 cm (7.8 in x 6.6 in x 3.5 in)
 |  
            | Weight: | Instrument: 1.1 kg (2.5 lb) Power supply: 400 g (0.9 lb)
 |  
            | Tamper protection: | Kensington lock slot |    
    
        
            | Input(power loggers) | Single Phase, Three Phase |  
            | Type(Power loggers) | Digital, Portable Hand Held |  
            | Maximum Current AC | 6000 A |  
            | Maximum Voltage AC | 1000 V |  
            | True RMS | Yes |  
            | Power Quality | No |  
            | Current Input Channels | 3 |  
            | Voltage Input Channels | 4 |  
            | Measurement Frequency | 50 Hz, 60 Hz |  
            | Display (Energy Management) | Digital, Graphical |  
            | Transient Capture | No |  
            | Displays Waveform | No |  
            | Energy | Yes |  
            | Phasor Diagrams | Yes |  
            | Power Factor (Power Quality) | Yes |  
            | Harmonics | No |  
            | Total Harmonic Distortion | Yes |  
            | Current Clamps Included | No |  
            | Blue Tooth Compatable | No |  
            | CAT Rating | IV |  
            | CAT Voltage Rating (V) | 600V |  
            |  |  
            | Unique Features | Circuit types: 1-φ, 1-φ IT, Split phase, 3-φ delta, 3-φ wye, 3-φ wye IT, 3-φ wye balanced, 3-φ Aron/Blondel (2-element delta), 3-φ delta open leg, Currents only (load studies) 
 Measured parameters Voltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental power, DPF, energy
 Averaging interval User selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min
 Averaging time min/max values Voltage, Current: Full cycle RMS updated every half cycle Aux, Power: 200ms
 Demand Interval (Energy Meter Mode)
 Measured parameters Energy (Wh, varh, VAh), PF, maximum demand, cost of energy
 Interval User selectable: 5 min, 10 min, 15 min, 20 min, 30 min, off
 |  
            | Warranty | 2 YEARS |  
            | Warranty Details | Instrument and power supply: Two-years (battery not included) Accessories: one-year
 Calibration cycle: two-years
 |  
            | Calibration Included | None |  
            | Power Supply Voltage | 120V 50/60 Hz |  
            | Safety Approval | CE |  
            | Data Logging | Yes |  
            | Interfaces I/O | Wifi, USB |  
            | Storage | Internal Memory |  
            | IP Rating | IP50 |  
            | Battery Type | Li-ion |  |  
					
                
        
        
              Accessories
              Current Clamps*Adapters
            
            
                
                        
                            | Product | Price |  
                            |  | Fluke I17XX-FLEX 6000/4PK 
                                    Catalog #: 4637430
iFlexi Current Clamp, 36 in. Circumference, 6000A, 4-Pack | $1,329.25
 
 |  
                            |  | Fluke i17XX-FLEX1500 
                                    Catalog #: 4637328
1500A 12 inch iFlex Current Clamp | $279.24
 
 |  
                            |  | Fluke I17XX-FLEX1500/3PK 
                                    Catalog #: 4637337
1500A 12 inch, 3 pack iFlex Current Clamp | $782.24
 
 |  
                            |  | Fluke I17XX-FLEX1500/4PK 
                                    Catalog #: 4637411
iFlexi Current Clamp, 12 in. Circumference, 1500A, 4-Pack | $1,051.24
 
 |  
                            |  | Fluke I17XX-FLEX3000 
                                    Catalog #: 4637343
3000A 24 inch iFlex Current Clamp | $317.24
 
 |  
                            |  | Fluke I17XX-FLEX3000/3PK 
                                    Catalog #: 4637355
3000A 24 inch, 3 pack iFlex Current Clamp | $782.24
 
 |  
                            |  | Fluke I17XX-FLEX3000/4PK 
                                    Catalog #: 4637427
iFlexi Current Clamp, 24 in. Circumference, 3000A, 4-Pack | $1,051.24
 
 |  
                            |  | Fluke I17XX-FLEX6000 
                                    Catalog #: 4637362
6000A 36 inch iFlex Current Clamp | $317.24
 
 |  
                            |  | Fluke I17XX-FLEX6000/3PK 
                                    Catalog #: 4637370
6000A 36 inch, 3 pack iFlex Current Clamp | $941.24
 
 |  
                            |  | Fluke I40S-EL3X 
                                    Catalog #: 4637396
Clamp-on Current Transformer | $415.25
 
 |  
                            |  | Fluke I40S-EL3X/3PK 
                                    Catalog #: 4637409
Clamp-on Current Transformers, 3pk | $1,175.25
 
 |  
				 |  
     |  |