Amprobe ACDC-52NAV
Catalog #: 3729961
1000V/600A TRMS AC/DC Navigator Clamp Meter w/ THD and NCV Detector, CAT IV Rated
- Overview
- Specifications
- Summary
Product Highlights
- True-rms technology improves accuracy in noisy environments
- Measures AC/DC voltage to 1000V, AC/DC current to 600A, plus resistance, frequency, capacitance, power and power factor, total harmonics distortion (THD) and individual harmonics from 1 to 25
- Includes inrush current measurement and phase rotation indication for 3-phase motors
- Non-contact voltage detection enhances safety
- Low pass filter enables measuring voltage and frequency on variable frequency drives
- Continuity beeper quickly identifies shorts and opens
- Large backlit digital display with analog bar graph presents the full picture
- Min, max and smart data hold
- Peak hold identifies spikes and transients
- In-jaw flashlight automatically lights when jaws open to illuminate dark panels and junction boxes
- Auto power off conserves battery life
- Maximum jaw opening accommodates large conductors up to 1.45 (37mm)
- Rubber overmold body absorbs shocks—drop proof to 4 feet (1.2m)
- CAT IV-rated AC/DC current clamp meter
Each Unit Includes
- 1 - Test leads
- 1 - users manual
- 1 - batteries (installed)
| Features |
ACD-50NAV |
ACD-51NAV |
ACDC-52NAV |
ACD-53NAV |
ACDC-54NAV |
Best Accuracy |
| AC Current |
100.00, 600.0A |
100.00, 1000.0A |
± (1.5% Rdg + 5 LSD) |
| DC Current |
|
|
100.00, 600.0A |
|
100.00, 1000.0A |
± (1.5% Rdg + 5 LSD) |
| AC Voltage |
100.00V, 1000V |
±(1.0% Rdg + 5 LSD) |
| DC Voltage |
100.00V, 1000V |
±(0.7% Rdg + 2 LSD) |
| Resistance |
1.0000KO, 10.00KO, 100.00KO |
±(1.0% Rdg + 3 LSD) |
| Frequency |
20.0Hz to 10KHz |
±(0.5% Rdg +3 LSD) |
| Capacitance |
4.000 µF, 400.0 µF, 4000 µF |
±(1.9% Rdg + 8 LSD) |
| DCµA |
|
1000.0µA |
|
|
|
±(1.7% Rdg + 2 LSD) |
| Temperature |
|
-58F to 1832F (-50°C to 1000°C) |
|
|
-58F to 1832F (-50°C to 1000°C) |
±(1% Rdg + 0.8°C) |
| THD (Total Harmonics Distortion) |
0.1% to 100.0% |
±(3.0% Rdg + 10 LSD) |
| Individual Harmonics |
1 to 25 |
|
| Power |
10kW to 600kW |
10kW to1000kW |
±(2.5% Rdg + 5 LSD) |
| Power Factor |
-1.00 to 1.00 |
± 3 degrees |
| Dimension (HxWxD) |
238.3 x 87.3 x 51.0mm (9.4 x 3.4 x 2in) |
238.3 x 87.3 x 51.0mm (9.4 x 3.4 x 2in) |
238.3 x 87.3 x 51.0mm (9.4 x 3.4 x 2in) |
260 x 87.3 x 51.0mm (10.2 x 3.4 x 2in) |
260 x 87.3 x 51.0mm (10.2 x 3.4 x 2in) |
|
| Weight |
380g (0.84lb) |
380g (0.84lb) |
380g (0.84lb) |
420g (0.93lb) |
420g (0.93lb) |
|
| Accessory |
Test leads (one pair), Carrying case and Manual |
Test leads (one pair), Temp. adapter probe, Carrying case and Manual |
Test leads (one pair), Carrying case and Manual |
Test leads (one pair), Carrying case and Manual |
Test leads (one pair), Temp. adapter probe, Carrying case and Manual |
| Clamp Meters/Clamp Meters Template |
| Type |
Standard Style |
| True RMS |
Yes |
| Maximum Current AC |
600 A |
| Maximum Current DC |
600 A |
| Maximum Voltage AC |
1000 V |
| Maximum Voltage DC |
1000 V |
| Basic Voltage Accuracy |
ACV: ± 1% Rdg + 5D; DCV: ± 0.7% Rdg + 2D |
| Counts |
9999 . |
| Maximum Conductor Size |
1.77 IN |
| Auto Ranging/Manual |
Both |
| Auto Power Off |
Yes |
| Detachable Jaw |
No |
| Rotating Jaw / Swivel |
No |
| Peak Hold |
Yes |
| Min/Max |
Yes |
| In-Rush Current |
Yes |
| Dual Display |
No |
| Analog Bargraph on Display |
Yes |
| Backlight |
Yes |
| Remote Display |
No |
| Resistance |
Yes |
| Frequency |
Yes |
| Continuity |
Yes |
| Capacitance |
Yes |
| Temperature (K T/C) |
No |
| Temperature (IR Sensor) |
No |
| Diode Testing |
Yes |
| CAT Rating |
III |
| CAT Voltage |
1,000 V |
| Overload Protector |
Yes |
| True Power (KW) |
Yes |
| Max True Power (KW) |
600 kW |
| Apparent Power (VA) |
No |
| Power Factor (PF) |
Yes |
| Single Phase/Three Phase |
Single Phase |
| Crest Factor |
Yes |
| Energy (KWh) |
No |
| Reactive Power (KVAR) |
No |
| Source/Simulate (Process Clamp) |
No |
| Unique Features |
Phase Rotation Indication, Non-contact Voltage Detection, Low Pass Filter for Variable Frequency Drives, Auto Torch-light When Clamping, Measures Total Harmonics Distortion, Easy to Use Single Hand Selection |
| Warranty |
1 YEARS |
| Warranty Details |
1 Year from the Date of Purchase, This Warranty Does Not Cover Fuses, Disposable Batteries or Damage from Accident, Neglect, Misuse, Alteration, Contamination or Abnormal Conditions of Operation or Handling |
| Additional Info/Comments |
Built-in Jaw Flashlight, Overmold Bodies to Absorb Shock |
| Product Weight |
435 GRAMS (0.959 LBS) |
| Product Height |
2 IN |
| Product Length |
9.4 IN |
| Product Width |
3.4 IN |
| Shipping Weight |
1.5 LBS |
| Data Logging |
No |
| Battery Type |
9v |
| Power Supply Voltage |
Battery Powered |
| Country of Origin |
Taiwan |
| Shipping Height |
3.30 IN |
| Shipping Length |
13.90 IN |
| Shipping Width |
9.10 IN |
|