Display: 3-3/4 digit liquid crystal display (LCD) with a maximum reading of 3999
Polarity: Automatic, positive implied, negative polarity indication
Overrange: (OL) or (-OL) is displayed
Zero: Automatic
Low Battery Indication: The indicator is displayed when the battery voltage drops below the operating level
Auto Power Off: Approx. 10 minutes
Measurement Rate: 2 times per second, nominal
Operating Environment: 0 ?C to 50 ?C at 70 % R.H.
Storage Temperature: -20 ?C to 60 ?C, 0 to 80 % R.H. with battery removed from meter
Accuracy: Stated accuracy at 23 ?C ? 5 ?C, 75 % relative humidity
Temperature Coefficient: 0.1 x (specified accuracy) per ?C (0 ?C to 18 ?C, 28 C to 50 ?C)
Altitude: 2000 m
Power: Single standard 9 volt battery, NEDA 1604, JIS 006P, IEC 6F22
Battery Life: 150 hours typical with carbon-zinc, 300 hours typical with alkaline
Dimensions: (H x W x D) 155 mm x 72 mm x 32 mm
Weight: Approx. 400 g including battery
Warranty: One-year
DC Volts Range: 400 mV, 4 V, 40 V, 400 V, 1000 V
AC Volts (45 Hz to 500 Hz) Range: 400 mV (45 Hz to 100 Hz)
AC Volts (45 Hz to 500 Hz) Range: 4 V, 40 V, 400 V, 750 V
Voltage Resolution: 100 µV
Input Impedance: 400 mV: 100 M? ; 4 V: 10 M? ; 40 V to 1000 V: 9.1 Mv
Overload Protection: 1000 V dc or 750 V ac rms
DC Current Range: 400 µA, 4000 µA, 40 mA, 400 mA ? (1.0 % rdg + 2 dgt)
DC Current Range: 2 A ? (2.0 % rdg + 3 dgts)
AC Current (45 Hz to 500 Hz) Range: 400 µA, 4000 µA, 40 mA, 400 mA ? (1.5 % rdg + 5 dgts)
AC Current (45 Hz to 500 Hz) Range: 2 A ? (2.5 % rdg + 5 dgts)
Current Resolution: 0.1 µA
Input Protection: 2 A/1000 V fast blow ceramic fuse 6.3 mm x 32 mm on A input
Burden Voltage: 500 mV max. (2 V max. on 4 mA, 400 mA ranges)
Resistance: 400 ? , 4 k? , 40 k? , 400 k? , 4 M? ? (1.0 % rdg + 4 dgts)
Resistance: 40 M? ? (2.0 % rdg + 5 dgts)
Resistance Resolution: 100 m?
Open Circuit Voltage: -0.45 V dc typical, (-1.2 V dc on 400 ? range)
Overload Protection: 1000 V dc or 750 V ac rms
Temperature: 400 ?C, 1000 ?C, 400 ?F, 1832 ?F
Range -20 ?C to 10 ?C Accuracy ? (2.0 % rdg + 4 ?C)
Range 10 ?C to 200 ?C Accuracy ? (1.0 % rdg + 3 ?C)
Range 200 ?C to 1000 ?C Accuracy ? (3.0 % rdg + 2 ?C)
Range -4 ?F to 50 ?F Accuracy ? (2.0 % rdg + 8 ?F)
Range 50 ?F to 400 ?F Accuracy ? (1.0 % rdg + 6 ?F)
Range 400 ?F to 1832 ?F Accuracy ? (3.0 % rdg + 4 ?F)
Resolution: 0.1 ?C, 0.1 ?F
Overload Protection: 1000 V dc or 750 V ac rms
Frequency: Range4 k, 40 k, 400 k, 1 M Accuracy ? (0.1 % rdg + 3 dgts)
Resolution: 1 Hz
Sensitivity: 10 Hz to 1 MHz: 2.5 V rms
Minimum Pulse Width: 25 ns
Duty Cycle Limits: 30 % and 70 %
Overload Protection: 1000 V dc or 750 V ac rms
Audible Indication: Less than 25 ?
Response Time: 100 ms
Overload Protection: 1000 VDC or 750 VAC rms
Test Current: Range 1.2 mA (approximate) Accuracy ? (1.5 % rdg + 3 dgts)
Resolution: 1 mV
Open Circuit Voltage: 3.0 dc typical
Overload Protection: 1000 V dc or 750 V ac rms
Non-Contact Voltage Indicator: Sense voltage 70 V to 600 V ac beeper chirps and big bright red LED comes on, works on all ranges
|