				Fluke 1587/MDT FC
                
                
                
 			 
				Catalog #: 4692716
2-in-1 Advanced Motor & Drive Kit with 9040, I400
 
 
                
                    OverviewSpecificationsSummaryAccessoriesCasesCurrent ClampsTemp. ProbesDMM Probe Kits 	
                    
				        
                        Product Highlights
    With the Fluke 1587 FC, perform insulation tests, plus a wide-range of DMM tasks with confidence and easeUse the Fluke i400 with your Fluke 1587 FC to accurately measure AC current without breaking the circuitCheck the rotation of three-phase motors easily and safely with the Fluke 9040 The Fluke 1587 FC 2-in-1 Insulation DMM 
    Pl/DAR measurements with TrendIt™ graphsMemory storage through Fluke Connect Measurements appTemperature Compensation through Fluke Connect Measurements appVFD low-pass filter for accurate motor drive measurementsInsulation test voltages 50 V, 100 V, 250 V, 500 V, 1000 VInsulation test voltages 500 V, 1000 VInsulation test: 0.01 MΩ to 2.0 GΩInsulation test: 0.1 MΩ to 600 MΩAuto-discharge of capacitive voltageInsulation test smoothing readingFrequency / Capacitance / Diode test / TemperatureMin/Max / AC/DC Voltage / DC Millivolts / AC/DC MilliampsResistance (0.1 Ω to 50 MΩ) / Continuity / Auto power offThree-year warranty / Remote probe, test leads, alligator clips, K-type thermocouple, hard case Fluke i400 AC Current Clamp 
    Use with your Fluke 1587 FC to measure 1A AC to 400 A AC1 mA/Amp output guarantees easy readingCAT III 1000 V / CAT IV 600 V overvoltage rating for added user protectionSpecially designed to offer maximum utility in a very compact shapeMaximum conductor: Ø 32 mm1 year warranty Fluke 9040 Phase Rotation Indicator 
    Large display to easily determine field rotation and phase sequenceIndication for all three phasesCAT III 600 V overvoltage rating2 year warranty 
 Each Unit Includes
    1587 Meter9040 Phase Rotation Indicatori400 ClampRemote probeTest leadsAlligator clipsK-type thermocoupleHard caseUser documentation 
                          
    
        
            | GENERAL SPECIFICATIONS |  
            | Maximum voltage applied to any terminal and common | 1000 V |  
            | Storage temperature | -40 °C to 60 °C (-40 °F to 140 °F) |  
            | Operating temperature | -20 °C to 55 °C (-4 °F to 131 °F) |  
            | Temperature coefficient | 0.05 x (specified accuracy) per °C for temperatures <18 °C or >28 °C (<64 °F or >82 °F) |  
            | Relative humidity | Noncondensing |  
            | 0 % to 95 % @ 10 °C to 30 °C | (50 °F to 86 °F) |  
            | 0 % to 75 % @ 30 °C to 40 °C | (86 °F to 104 °F) |  
            | 0 % to 40 % @ 40 °C to 55 °C | (104 °F to 131 °F) |  
            | Vibration | Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument |  
            | Radio frequency communication | 2.4 GHz ISM Band |  
            | Radio frequency certification | FCC: T68-FBLE, IC: 6627A-FBLE |  
            | Electromagnetic compatibility |  
            | International IEC 61326-1 | Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class A : Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. 
 Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
 
 Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. The equipment may not meet the immunity requirements of this standard when test leads and/or test probes are connected.
 |  
            | Korea (KCC) | Class A Equipment (Industrial Broadcasting & Communication Equipment) Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
 |  
            | USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. |  
            | Enclosure protection | IEC 60529: IP40 (non-operating) |  
            | Safety | IEC 61010-1 | Pollution Degree 2 |  
            | IEC 61010-2-033 | CAT IV 600 V/CAT III 1000 V |  
            | Batteries | Four AA batteries (NEDA 15A or IEC LR6) |  
            | Battery life | Meter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MO with a duty cycle of 5 seconds on and 25 seconds off. |  
            | Size | 5.0 cm H x 10.0 cm W x 20.3 cm L (1.97 in H x 3.94 in W x 8.00 in L) |  
            | Weight | 550 g (1.2 lb) |  
            | Altitude | Operating | 2000 m |  
            | Storage | 12,000 m |  
            | Over-Range capability | 110 % of range except for capacitance which is 100 % |  
            | Frequency overload protection | <107 V-Hz |  
            | Fuse Protection for mA input | 0.44A, 1000 V, IR 10 kA |    
    
        
            | ELECTRICAL SPECIFICATIONS |  
            | AC voltage measurement |  
            | Accuracy (1587 FC only) |  
            | Range | Resolution | 50 Hz to 60 Hz ± (% of Rdg + counts) | 60 Hz to 5000 Hz ± (% of Rdg + counts) |  
            | 600.0 mV | 0.1 mV | ± (1 % + 3) | ± (2 % + 3) |  
            | 6.000 V | 0.001 V | ± (1 % + 3) | ± (2 % + 3) |  
            | 60.00 V | 0.01 V | ± (1 % + 3) | ± (2 % + 3) |  
            | 600.0 V | 0.1 V | ± (1 % + 3) | ± (2 % + 3) 1 |  
            | 1000 V | 1 V | ± (2 % + 3) | ± (2 % + 3) 1 |  
            | 1 1 kHz bandwidth |  
            | Low-Pass Filter Voltage (1587 FC only) |  
            | Range | Resolution | 50 Hz to 60 Hz ± (% of Rdg + Counts) | 60 Hz to 400 Hz ± (% of Rdg + Counts) |  
            | 600.0 mV | 0.1 mV | ± (1 % + 3) | + (2 % + 3) - (6 % - 3) |  
            | 6.000 V | 0.001 V | ± (1 % + 3) | + (2 % + 3) - (6 % - 3) |  
            | 60.00 V | 0.01 V | ± (1 % + 3) | + (2 % + 3) - (6 % - 3) |  
            | 600.0 V | 0.1 V | ± (1 % + 3) | + (2 % + 3) - (6 % - 3) |  
            | 1000 V | 1 V | ± (2 % + 3) | + (2 % + 3) - (6 % - 3) |    
    
        
            | 1577 accuracy |  
            | Range | Resolution | 50 Hz to 60 Hz ± (% of Rdg + Counts) |  
            | 600.0 mV | 0.1 mV | ± (2 % + 3) |  
            | 6.000 V | 0.001 V | ± (2 % + 3) |  
            | 60.00 V | 0.01 V | ± (2 % + 3) |  
            | 600.0 V | 0.1 V | ± (2 % + 3) |  
            | 1000 V | 1 V | ± (2 % + 3) |  
            | AC Conversion | Inputs are ac coupled true-rms responding and specified from 5 % to 100 % of range. Input signal crest factor can be up to 3 up to 500 V, decreasing linearly to a crest factor =1.5 at 1000 V. For non-sinusoidal waveforms add ± (2 % reading + 2 % FS) typical, for a crest factor up to 3. |  
            | Input Impedance | 10 MΩ (nominal), <100 pF, ac-coupled |  
            | Common mode rejection ratio (1 kΩ unbalanced) | >60 dB at dc, 50 or 60 Hz |  
            | DC voltage measurement |  
            | Range | Resolution | Accuracy 1587 FC1 ± (% of Rdg + Counts)
 | Accuracy 15771 ± (% of Rdg + Counts)
 |  
            | 6.000 V dc | 0.001 V | ± (0.09 % + 2) | ± (0.2 % + 2) |  
            | 60.00 V dc | 0.01 V | ± (0.09 % + 2) | ± (0.2 % + 2) |  
            | 600.0 V dc | 0.1 V | ± (0.09 % + 2) | ± (0.2 % + 2) |  
            | 1000 V dc | 1 V | ± (0.09 % + 2) | ± (0.2 % + 2) |  
            | 1 Accuracies apply to ± 100% of range. |  
            | Input Impedance: 10 MΩ (nominal), <100 pF |  
            | Normal mode rejection ratio: >60 dB @ 50 Hz or 60 Hz |  
            | Common mode rejection ratio: >120 dB @ dc, 50 Hz or 60 Hz (1 k unbalanced) |  
            | DC millivolts measurement |  
            | Range | Resolution | Accuracy 1587 FC ± (% of Rdg + Counts) | Accuracy 1577 ± (% of Rdg + Counts) |  
            | 600.0 mV dc | 0.1 mV | ± (0.1 % + 1) | ± (0.2 % + 1) |  
            | DC and AC current measurement |  
            | Range | Resolution | Accuracy 1587 FC ± (% of Rdg+Counts) | Accuracy 1577 ± (% of Rdg+Counts) | Burden voltage (Typical) |  
            | AC 45 Hz to 1000 Hz | 400 mA | 0.1 mA | ± (1.5 % + 2) 1 | ± (2 % + 2) 1 | 2 mV/mA |  
            | 60 mA | 0.01 mA | ± (1.5 % + 2) 1 | ± (2 % + 2) 1 |  |  
            | DC | 400 mA | 0.1 mA | ± (0.2 % + 2) | ± (1.0 % + 2) | 2 mV/mA |  
            | 60 mA | 0.01 mA | ± (0.2 % + 2) | ± (1.0 % + 2) |  |  
            | 1 1 kHz bandwidth |  
            | Overload: 600 mA for 2 minutes maximum |  
            | Fuse protection for mA Input: 0.44 mA, 1000 V, IR 10 kA |  
            | AC conversion: Inputs are ac coupled true-rms responding and specified from 5 % to 100 % of range. Input signal crest factor can be up to 3 up to 300 mA, decreasing linearly to crest factor =1.5 at 600 mA. For non-sinusoidal waveforms add +(2 % reading + 2 % FS) typical, for a crest factor up to 3. |  
            | Ohms measurement |  
            | Range | Resolution | Accuracy 1587 FC1 + (% of Rdg+Counts)
 | Accuracy 15771 + (% of Rdg+Counts)
 |  
            | 600.0 Ω | 0.1 Ω | ± (0.9 % + 2) | ± (1.2 % + 2) |  
            | 6.000 kΩ | 0.001 kΩ |  
            | 60.00 kΩ | 0.01 kΩ |  
            | 600.0 kΩ | 0.1 KΩ |  
            | 6.000 MΩ | 0.001 MΩ |  
            | 50.0 MΩ [2] | 0.01 MΩ | ± (1.5 % + 3) | ± (2.0 % + 3) |  
            | 1 Accuracies apply from 0 % to 100 % of range. 2 Up to 80 % relative humidity. |  
            | Overload protection: 1000 V rms or dc |  
            | Open circuit test voltage: <8.0 V dc |  
            | Short circuit current: <1.1 mA |  
            | Diode test (1587 FC only) |  
            | Diode test indication | Display voltage drop: 0.6 V at 1.0 mA nominal test current |  
            | Accuracy | ± (2 % + 3) |  
            | Continuity test |  
            | Continuity indication | Continuous audible tone for test resistance below 25 O and off above 100 O. Maximum reading; 1000 O |  
            | Open circuit voltage | <8.0 V |  
            | Short circuit current | 1.0 mA typical |  
            | Overload protection | 1000 V rms |  
            | Response time | >1 m sec |  
            | Frequency measurement (1587 FC only) |  
            | Range | Resolution | Accuracy ± (% of Rdg+Counts) |  
            | 99.99 Hz | 0.01 Hz | ± (0.1 % + 1) |  
            | 999.9 Hz | 0.1 Hz | ± (0.1 % + 1) |  
            | 9.999 kHz | 0.001 kHz | ± (0.1 % + 1) |  
            | 99.99kHz | 0.01 kHz | ± (0.1 % + 1) |  
            | Frequency counter sensitivity |  
            | Input range | V ac Sensitivity (RMS Sine Wave)1 | DC trigger levels to 20 kHz2 |  
            | 5 Hz to 20 kHz | 20 kHz to 100 kHz |  |  
            | 600.0 mV ac | 100.0 mV | 150.0 mV | NA |  
            | 6.0 V | 1.0 V | 1.5 V | -400.0 mV and 2.5 V |  
            | 60.0 V | 10.0 V | 36.0 V | 1.2 V and 4.0 V |  
            | 600.0 V | 100.0 V |  | 12.0 V and 40.0 V |  
            | 1000.0 V | 300.0 V |  | 12.0 V and 40.0 V |  
            | 1 Maximum input for specified accuracy = 10x range (1000 V max). Noise at low frequencies and amplitudes may affect accuracy. |  
            | 2 Usable to 100 kHz with full scale input. |  
            | Capacitance (1587 FC only) |  
            | Range | Resolution | Accuracy ± (% of Rdg+Counts) |  
            | 1000 nF | 1 nF | ± (1.2 % + 2) |  
            | 10.00 µF | 0.01 µF |  
            | 100.0 µF | 0.1 µF | ± (1.2 % + 90 counts) |  
            | 9999 µF | 1 µF |  
            | Temperature measurement (1587 FC only) |  
            | Range | Resolution | Accuracy 1 ± (% of Rdg+Counts) |  
            | -40 ° C to 537 ° C | 0.1 °C | ± (1 % + 10 counts) |  
            | -40 ° F to 998 ° F | 0.1 °F | ± (1 % + 18 counts) |  
            | 1 Accuracies apply following 90 minutes settling time after a change in the ambient temperature of the instrument. |  
            | INSULATION SPECIFICATIONS |  
            | Measurement range | Model 1587 FC: 0.01 MΩ to 2 GΩ Model 1577: 0.1 MΩ to 600 MΩ
 |  
            | Test voltages | Model 1587 FC: 50, 100, 250, 500, 1000 V Model 1577: 500, 1000 V
 |  
            | Test voltage accuracy | +20 %, -0 % |  
            | Short-Circuit test current | 1 mA nominal |  
            | Auto discharge | Discharge time <0.5 second for C = 1 µF or less |  
            | Live circuit detection | Inhibit test if terminal voltage > 30 V prior to initialization of test |  
            | Maximum capacitive load | Operable with up to 1 µF load |    
    
        
            | Micro / Milli / Meg Ohmmeters/Megohmmeter / Insulation Resistance Testers Template |  
            | Type | Battery |  
            | IR Test Voltage | 1,000 V, 100 V, 250 V, 50 V, 500 V |  
            | Maximum Insulation Resistance | 2 G Ohms |  
            | Minimum Insulation Resistance | 0.01 M Ohms (0.00001 G Ohms) |  
            | Variable Incremental Voltage | No |  
            | Display (Megohmmeter) | Digital |  
            | Continuity Test | Yes |  
            | Live Circuit Voltage Detection | Yes |  
            | Power Supply | Battery |  
            | Timer | No |  
            | CAT Rating | IV |  
            | CAT Voltage | 1,000 V, 600 V |  
         
            | Unique Features | Insulation test voltages 50V, 100V, 250V, 500V, 1000V Insulation test: 0.01 MΩ to 2.0 GΩ
 Auto discharge of capacitive voltage
 Insulation test smoothing reading
 Frequency
 Capacitance
 Diode test
 Temperature
 Min/Max
 Low pass filter (for work on VSD's)
 AC/DC Voltage
 DC millivolts
 AC/DC milliamps
 |  
            | Warranty | 3 YEARS |  
            | Calibration Included | None |  
            | Power Supply Voltage | Battery Powered |  
            | Safety Approval | CSA |  
            | Data Logging | No |  
            | IP Rating | IP40 |  
            | Product Weight | 4.72 LBS |  
            | Battery Type | AA |  
            | Product Height | 7.99 IN |  
            | Product Length | 3.97 IN |  
            | Product Width | 7.96 IN |  
            | Shipping Weight | 5.19 LBS |  
            | Country of Origin | United States |  
            | Shipping Height | 7.99 IN |  
            | Shipping Length | 3.97 IN |  
            | Shipping Width | 7.96 IN |  
            | UPC | 095969262958 |  |  
					
                
        
        
              Accessories
            
            
                
                        
                            | Product | Price |  
                            |  | Fluke AC285 
                                    Catalog #: 1610159
SureGrip Alligator Clips | $60.24
 
 |  
                            |  | Fluke L200 
                                    Catalog #: 2096346
Light Probe | $60.24
 
 |  
                            |  | Fluke L210 
                                    Catalog #: 2096379
Probe Light and Probe Extender | $80.24
 
 |  
                            |  | Fluke TP220 
                                    Catalog #: 1670056
SureGrip Industrial Test Probes | $60.24
 
 |  
                            |  | Fluke TP74 
                                    Catalog #: 1541649
Lantern Tip Test Probes | $60.24
 
 |  
                            |  | Fluke TPAK 
                                    Catalog #: 1281997
Meter Hanging Kit | $75.25
 
 |  
              Cases
            
            
                
                        
                            | Product | Price |  
                            |  | Fluke C101 
                                    Catalog #: 2437514
Universal Hard Carrying Case | $110.24
 
 |  
                            |  | Fluke C125 
                                    Catalog #: 646858
Compact Soft Case | $60.24
 
 |  
                            |  | Fluke C25 
                                    Catalog #: 681114
Large Soft Case for DMMs | $2.00
 
 |  
                            |  | Fluke C550 
                                    Catalog #: 1547919
Tool Bag | $145.24
 
 |  
                            |  | Fluke CXT170 
                                    Catalog #: 3352567
Extreme Case | $264.24
 
 |  
              Current Clamps
            
            
                
                        
                            | Product | Price |  
                            |  | Fluke I200 
                                    Catalog #: 664755
Current Probe | $219.24
 
 |  
                            |  | Fluke I400 
                                    Catalog #: 2277225
Current Clamp Adaptor | $199.24
 
 |  
                            |  | Fluke I410 
                                    Catalog #: 617727
AC/DC Current Clamp Adaptor | $329.24
 
 |  
              Temp. Probes
            
            
                
                        
                            | Product | Price |  
                            |  | Fluke 80AK-A 
                                    Catalog #: 2747812
K-Type Interface Adapter | $60.24
 
 |  
                            |  | Fluke 80PK-10 
                                    Catalog #: 3439199
Pipe Clamp Temperature Probe | $335.24
 
 |  
                            |  | Fluke 80PK-18 
                                    Catalog #: 3448859
Pipe Clamp Temperature Probe Kit | $482.24
 
 |  
                            |  | Fluke 80PK-27 
                                    Catalog #: 2098723
SureGrip Industrial Surface Temperature Probe | $465.26
 
 |  
                            |  | Fluke 80PK-3A 
                                    Catalog #: 874610 
Surface Probe | $219.24
 
 |  
                            |  | Fluke 80PK-8 
                                    Catalog #: 200360
Pipe Clamp Temperature Probe | $239.24
 
 |  
              DMM Probe Kits
            
            
                
                        
                            | Product | Price |  
                            |  | Fluke TL27 
                                    Catalog #: 668571
Heavy Duty Test Lead Set | $50.24
 
 |  
                            |  | Fluke TLK-225 
                                    Catalog #: 2097031
SureGrip Master Accessory Kit | $244.26
 
 |  
				 |  
     |  |