				Fluke Calibration 9100S-D-156
                
                
                
 			 
				Catalog #: 1885157
HDRC Handheld Dry-Well D
 
 
                
                    OverviewSpecificationsSummaryInsertsCases 	
                    
				        
                        Product Highlights
    Smallest dry-wells in the worldRanges from –10°C to 375°CAccuracy to ±0.25°C, stability of ±0.05°C at 0°CRS-232 interface with 9930 Interface-it v3.81 software The constant temperature block is available in the following configurations. 
    Block “A” has six holes, four that accept probe diameters of 1/4”, 5/32”, 1/8”, and 1/16”, and two that accept probes of 3/16” diameter to allow comparison calibrations.Block “B” has four holes that accept probe diameters of 3/8”, 1/4”, 3/16” and 1/8”.Block “C” has two holes that accept probe diameters of 3/16” and 1/2”.Block “D” has six holes, two that accept probe diameter of 3 mm, two that accept probes of 4 mm diameter, and two that accept probes of 6 mm diameter. Surrounding the well opening are small ventilation holes which provide cooling to the instrument. Each Unit Includes
    9100S Dry-wellPower CordUser’s Guide with Report of CalibrationRS-232 Cable9930 Interface-it Software and User’s GuideNIST Calibration 
                        
    
        
            | Specifications | 9100S | 9102S |  
            | Range | 35 °C to 375 °C (95 °F to 707 °F | –10 °C to 122 °C (14 °F to 252 °F) at23 °C ambient |  
            | Accuracy | ± 0.25 °C at 50 °C; ± 0.25 °C at 100 °C; ± 0.5 °C at 375 °C | ± 0.25 °C |  
            | Stability | ± 0.07 °C at 50 °C; ± 0.1 °C at 100 °C; ± 0.3 °C at 375 °C | ± 0.05 °C |  
            | Well-to-Well Uniformity | ± 0.2 °C with sensors of similar size at equal depths within wells |  
            | Heating Times | 35 °C to 375 °C: 9.5 minutes | ambient to 100 °C: 10 minutes |  
            | Stabilization | 5 minutes | 7 minutes |  
            | Cooling Times | 375 °C to 100 °C: 14 minutes | ambient to 0 °C: 10 minutes |  
            | Well Depth | 102 mm (4 in);1.6 mm (1/16 in) hole is 89 mm (3.5 in) deep | 102 mm (4 in) |  
            | Removable Inserts | N/A | Available in sizes from 1.6 mm (1/16 in) to 11.1 mm (7/16 in) [6.4 mm (1/4 in) and 4.8 mm (3/16 in) included] |  
            | Power | 115 V ac (± 10 %), 55–65 Hz, 1.5 A or 230 V ac (± 10 %), 0.8 A, 45–55 Hz, 175 W | 94-234 V ac (± 10 %), 50/60 Hz, 60 W;or 12 VDC |  
            | Size (HxWxD) | 57 x 125 x 150 mm (2.25 x 4.9 x 6.1 in) | 99 x 140 x 175 mm (3.9 x 5.5 x 6.9 in) |  
            | Weight | 1 kg (2 lb 3 oz) | 1.8 kg (4 lb) |  
            | Computer Interface | RS-232 included with free Interface-it software |  
            | NIST-TraceableCalibration | Data at 50 °C, 100 °C, 150 °C, 200 °C,250 °C, 300 °C, and 375 °C | Data at –10 °C, 0 °C, 25 °C, 50 °C, 75 °C,100 °C, and 122 °C |    
    
        
            | Calibration Baths |  
            | Type | Dry |  
            | Min Temp (Caiibration Baths) | 35 C |  
            | Max Temp (Calibration Baths) | 375 C |  
            | Accuracy (Calibration Baths) | 0.25 C |  
            | Voltage (Calibration Baths) | 115 VAC |  
            | Special Features (Calibration Baths) | PC Software |  
         
            | Unique Features | Block “D” has six holes, two that accept probe diameter of 3 mm, two that accept probes of 4 mm diameter, and two that accept probes of 6 mm diameter |  
            | Calibration Included | NIST Calibration |  
            | Interfaces I/O | RS-232 |  
            | ECCN Number | EAR99 |  
            | Country of Origin | United States |  |  
					
                
        
        
              Inserts
            
            
                
                        
                            | Product | Price |  
                            |  | Fluke Calibration 3102-0 
                                    Catalog #: 1650985
Insert, AL 1/2" X 4" Blank for Fluke 9102/9009 Handheld Dry-Well | $278.24
 
 |  
                            |  | Fluke Calibration 3102-1 
                                    Catalog #: 1650997
INSERT, AL 1/16IN (9102, 9009) | $278.24
 
 |  
                            |  | Fluke Calibration 3102-2 
                                    Catalog #: 1651002
Insert, 1/8 in (3.2 mm) : (9102, 9009) | $290.24
 
 |  
                            |  | Fluke Calibration 3102-3 
                                    Catalog #: 1651016
Insert AL 1/2" X 4" 3/16" (9102, 9009) | $278.24
 
 |  
                            |  | Fluke Calibration 3102-4 
                                    Catalog #: 1651025
Insert, 1/4 in (6.4 mm) : (9102, 9009) | $278.24
 
 |  
                            |  | Fluke Calibration 3102-5 
                                    Catalog #: 1651033
Insert, 5/16 in (7.9 mm) : (9102, 9009) | $278.24
 
 |  
                            |  | Fluke Calibration 3102-6 
                                    Catalog #: 1651040
Insert, 3/8 in (9.5 mm) : (9102, 9009) | $290.24
 
 |  
                            |  | Fluke Calibration 3102-7 
                                    Catalog #: 1651057
Insert, 7/16 in (11.1 mm) : (9102, 9009) | $290.24
 
 |  
                            |  | Fluke Calibration 3102-8 
                                    Catalog #: 1651069
Insert, 5/32 in (4 mm) : (9102, 9009) | $290.24
 
 |  
              Cases 
				 |  
     |  |