| Fluke Norma Series power analyzers at a glance | 
        
            |  | Norma 4000 | Norma 5000 | 
        
            | Number of Phases | 1 or 3 | 3, 4 or 6 | 
        
            | Bandwidth | DC to 3 MHz or dc to 10 MHz depending on input module | 
        
            | Basic Accuracy | 0.2%, 0.1% or 0.03% depending on input modules | 
        
            | Sampling Rate | 0.33 MHz or 1 MHz depending on input modules | 
        
            | Voltage Input Range | 0.3 to 1000 V | 
        
            | Current Input Range (direct, not via shunt) | 0.03 mA – 20 A depending on input module | 
        
            | Display | Color, 5.7“ / 144 mm - 320 x 240 pixel | 
        
            | Fast Fourier Transformation (FFT) | To the 40th harmonic | 
        
            | RS232 Interface | Standard | 
        
            | PI1 Process Interface (8 analog / impulse inputs and 4 analog outputs) | Optional | 
        
            | IEEE 488/GPIB Interface | Optional | 
        
            | Fluke NormaView PC Software (for data download, analysis & report writing) | Standard | 
        
            | Basic Function | 
        
            | Included functions | 
                Fast Fourier Transformation (FFT)Digital Oscilloscope (DSO)Integration function (energy)Vector DisplayRecorderRAM data memoryConfiguration | 
        
            | Measured Values | 
        
            | Working Temperature Range | Non-gapping calculation of averaged values for each phase. In three phase system additionally calculation of total power and averaging of V and I of the three phases. The fundamental H01 will be calculated in synchronous mode also for these values. Urms effective value, Urm rectified mean, Um mean valueUp-, Up+, Upp peak values
 Ucf crest factor Ucf, Uff form factor
 Ufc fundamental content
 Uthd distortion factor DIN, IEC
 Irms effective value, Irm rectified mean, Im mean value
 Ip-, Ip+, Ipp peak values
 Icf crest factor Icf, Iff form factor
 Ifc fundamental content
 Ithd distortion factor DIN, IEC
 P active power [W]
 Q reactive power [Var]
 S apparent power [VA]
 ë, cos. phase angular
 Integral function for active power P, reactive power Q, apparent power S,
 voltage (Um) and current (Im),
 Number of digits 4 or 5 dependent on measured value.
 | 
        
            | Frequency and Synchronization | 
        
            | Range | DC and 0.2 Hz to sample rate | 
        
            | Accuracy | ±0.01 % of measured value (reading) | 
        
            | General Specifications | 
                Channels which can be selected: all U/I or external input.One of three low pass filter with different frequencies can be switched into the signal.The frequency is always visible on the top of the screen.The BNC synchronization socket on backside of the instrument can be used either as input or output.The input signals can be measured up to the sample rate of the power phase. The maximum level must not be higher then 50V.The output signal is a pulsed 5Volts TTL signal (frequency depends on the measured synch frequency). | 
        
            | Power Phase Channels | 
        
            | Range | PP42 | PP50 | PP54 | PP64 | 
        
            | Accuracy | 0.2% (0.1% rd + 0.1 % rg) | 0.1% (0.05% rd + 0.05 % rg) | 0.1% (0.05% rd + 0.05 % rg) | 0.03% (0.02% rg + 0.01% rg) | 
        
            | Current Range | 20 A | 10 A | 10 A | 10 A | 
        
            | Sampling Rate | 341 kHz | 1 MHz | 341 kHz | 341 kHz | 
        
            | Bandwidth | 3 MHz | 10 MHz | 3 MHz | 3 MHz | 
        
            | Configuration Memory | 
        
            | Memory for Configurations | 4 MB Up to 15 user configurations can be saved into a permanent memory and reloaded later on. Changes that were not saved are lost after switching off the instrument.
 | 
        
            | Memory for Settings | Standard | 
        
            | Ambient Conditions | 
        
            | Working Temperature Range | 5 °C to 35 °C (41 °F to 95 °F) | 
        
            | Storage Temperature Range | -20 °C to 50 °C (-4 °F to 122 °F) | 
        
            | Housing Material | Fluke Norma Power Analyzers are extremely compact and equipped with a solid metal case to meet stringent EMC requirements. | 
        
            | Climatic Class | KYG DIN 40040, max. 85 % relative humidity, non-condensing. | 
        
            | Power supply | 85 V ac to 264 V ac, 50 Hz to 60 Hz, dc 100 to 260 V, ca. 40 VA European plug with switch. Binding post for current available on some models. | 
        
            | Measuring Inputs | Safety sockets 4 mm, 2 for each input. External shunt connection over BNC socket. | 
        
            | Operation | Membrane keyboard with cursor – function keys and direct functions. | 
        
            | Connections | Rear panel of the 3-phase Analyzer | 
        
            | Standards and Safety | 
        
            | Electrical Safety | EN 61010-1 / 2nd Edition 1000 V CAT II (600V CAT III) Degree of pollution 2, safety Class I
 EN 61558 for transformer
 EN 61010-2-031/032 for accessories
 | 
        
            | Maximum inputs | For voltage inputs Measurement range 1000 Veff, 2 kVpeak For voltage inputs Measurement range 1000 Veff, 2 kVpeak
 | 
        
            | Test Voltage | 
        
            | Net input case (protective conductor) | 1.5 KV AC | 
        
            | Net connection Measurement input | 5.4 kV AC | 
        
            | Measurement inputs Case | 3.3 kV AC | 
        
            | Measurement input input | 5.4 kV | 
        
            | Electromagnetic susceptibility | 
        
            | Emission | IEC 61326-1, EN 50081-1, EN 55011 Class B | 
        
            | Immunity | IEC 61326-1 / Annex A (industrial sector), EN 50082-1 | 
        
            | Physical Dimensions | 
        
            | Size | 
        
            | Norma 4000 | 5.9 in x 9.3 in x 12.4 in (150 mm x 237 mm x 315 mm) | 
        
            | Norma 5000 | 5.9 in x 17.6 in x 12.4 in (150 mm x 447 mm x 315 mm) | 
        
            | Weight | 
        
            | Norma 4000 | Approx. 11 lb. (5 kg) | 
        
            | Norma 5000 | Approx. 15 lb. (7 kg) |