				Fluke T3000 FC KIT
                
                
                
 			 
				Catalog #: 4465652
FC Wireless Essential Kit with T3000
 
 
 
                
                    OverviewSpecificationsSummaryAccessories 	
                    
				        
                        Product Highlights Fluke T3000 FC Wireless K-Type Temperature Module 
    Use as a standalone meter or as part of the systemLogging function for recording and saving up to 65,000 readings Fluke 3000 FC Series Wireless Multimeter 
    Save money and time by taking multiple measurements simultaneouslyIsolate interruptions or record signal fluctuations without even being there using the log function on the modulesWork with fewer interruptions by recording multiple sessions before downloadingCapture readings at different intervals, with user-set recording intervals from one second to one hourChoose the module(s) that work best for your applications—voltage, current, and temperature.View up to 10 live readings at once on the  Fluke Connect™ mobile appView up to six live readings at once on a PC to get a complete understanding of the situation and download logging sessions (PC Adapter sold separately)Add the 3000 FC Digital Multimeter or Ti200/300/400 Infrared Camera to monitor  modules on the moveNo more run-around. See multiple measurements in one place at the same timeNo more writing data down. Capture single or multiple logging sessions using the recording capabilityAvoid awkward or uncomfortable measurement positions. Set up the measurement once, step back and read it as many times as you want, when you want. Fluke Connect Features: 
    Fluke Connect allows you to wirelessly transfer data from your existing Fluke tools to your smart phoneFits over the IR port of your existing Fluke toolsUpgradeable by USBImmediately enables you to graph, save, and share the tool’s readings with your team from your smart phone Supported smart phones: 
    Android™ 4.3 & upiPhone® 4s & later Each Unit Includes 
    (1) T3000 FC Wireless K-Type Temperature Module(1) TL222 Test Lead set(1) AC220 Alligator Clip set(1) 3000 FC Wireless Multimeter(1) Test lead set(1) Alligator clip set(1) Magnetic hanging strap 
                         Fluke T3000 FC Wireless K-Type Temperature Module
 
    
        
            | Range | K-type: -200°C to 1372°C |  
            | Resolution | 0.1°C |  
            | Accuracy | ± [0.5% + 0.3°C] counts |  
            | Input terminals | K-type mini |  
            | LCD w/backlight | 3 ½ digits |  
            | Log rate/interval | 1 sec minimum/adjustable by PC |  
            | Battery type | 2 AA, NEDA 15A, IEC LR6 |  
            | Battery life | 400 hours |  
            | Memory | Record up to 65,000 readings |  
            | RF communications | 2.4 GHZ ISM Band |  
            | RF communication range | Open air, unobstructed: Up to 20 m Obstructed, sheetrock wall: Up to 6.5 m
 Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
 |  
            | Operating temperature | -10°C to +50°C |  
            | Storage temperature | -40°C to +60°C |  
            | Temperature coefficient | 0.01% of reading +0.03°C per °C |  
            | Temperature scale | ITS-90 |  
            | Operating humidity | 90% at 35°C, 75% at 40°C, 45% at 50°C |  
            | Altitude | Operating: 2,000 m Storage: 12,000 m
 |  
            | EMC | EN 61326-1:2006 |  
            | Safety compliance | IEC 61010-1, CAT I, 3rd edition Pollution Degree 2 |  
            | Certifications | CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE |  
            | Ingress Protection (IP) rating | IP42 |  
            | Pollution Degree | 2 |  
            | Size (HxWxD) | 16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in) |  
            | Weight | .22 kg (8 oz) |  
            | (Not compatible with Fluke CNX test tools) |  Fluke 3000 FC Series Wireless Multimeter
 
 
    
        
            | Fluke 3000 FC Series Wireless Multimeter |  
            | Detailed specifications (Not compatible with Fluke CNX test tools)For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ± ([ % of Reading ] + [ Number of least significant digits ]).
 |    
    
        
            | AC voltage |  
            | Range 1 | Resolution | Accuracy2,3,4 |  
            | 45 Hz to 500 Hz | 500 Hz to 1 kHz |  
            | 600.0 mV | 0.1 mV | 1.0 % + 3 | 2.0 % + 3 |  
            | 6000 V | 0.001 mV | 1.0 % + 3 | 2.0 % + 3 |  
            | 60.00 V | 0.01 mV | 1.0 % + 3 | 2.0 % + 3 |  
            | 600.0 V | 0.1 mV | 1.0 % + 3 | 2.0 % + 3 |  
            | 1000 V | 1 mV | 1.0 % + 3 | 2.0 % + 3 |  
            | 1 All ac voltage ranges are specified from 1 % of range to 100 % of range. 2 Crest factor of = 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
 3 For non-sinusoidial waveforms, add ± (2 % of reading + 2 % full scale) typical, for crest factor up to 3.
 4 Do not exceed 10 7 V-Hz.
 |    
    
        
            | DC voltage, continuity, resistance, diode test and capacitance |  
            | Function | Range | Resolution | Accuracy |  
            | mV | 600.0 mV | 0.1 mV | 0.09 % + 2 |  
            | V | 6.000 V | 0.001 V | 0.09 % + 2 |  
            | 60.00 V | 0.01 V |  
            | 600.0 V | 0.1 V |  
            | 1000 V | 1 V | 0.15 % + 2 |  
            | Ω | 600.0 Ω | 1 Ω | Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 us or longer. |  
            | Diode test | 2.000 V | 0.001 V | 1 % + 2 |  
            | µF | 1000 nF | 1 nF | 1.2 % + 2 |  
            | 10.00 µF | 0.01 µF |  
            | 100.0 µF | 0.1 µF |  
            | 9999 µF 1 | 1 µF | 10 % typical |  
            | 1 In the 9999 µF range for measurements to 1000 µF, the measurement accuracy is 1.2 % + 2. |    
    
        
            | AC and DC current |  
            | Function | Range 1 | Resolution | Accuracy |  
            | mA AC (45 Hz to 1 kHZ) | 60.00 mA | 0.01 mA | 1.5 % + 3 |  
            | 400.0 mA 3 | 0.1 mA |  
            | mA DC 2 | 60.00 mA | 0.01 mA | 0.5 % + 3 |  
            | 400.0 mA 3 | 0.1 mA |  
            | 1All ac current ranges are specified from 5 % of range to 100 % of range. 2Input burden voltage (typical): 400 mA input 2 mV/m
 3400.0 mA accuracy specified up to 600 mA overload.
 |    
    
        
            | Frequency |  
            | Range | Resolution | Accuracy 1 |  
            | 99.99 Hz | 0.01Hz | 0.1 % + 1 |  
            | 999.9 Hz | 0.1 Hz |  
            | 9.999 kHz | 0.001 kHz |  
            | 99.99 kHz | 0.01 kHz |    
    
        
            | General specifications (Not compatible with Fluke CNX test tools) |  
            | Maximum voltage between any terminal and earth ground | 1000 V dc or ac rms |  
            | Ω fuse protection from A inputs | 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only |  
            | Display (LCD) | Update rate: 4/sec Votls, amps, ohms: 6000 counts
 Frequency: 10,000 counts
 Capacitance: 1,000 counts
 |  
            | Battery type | Three AA Alkaline batteries, NEDA 15A IEC LR6 |  
            | Battery life | 250 hours minimum |  
            | RF communications | 2.4 GHZ ISM Band |  
            | RF communication range | Open air, unobstructed: Up to 20m Obstructed, sheetrock wall: Up to 6.5m
 Obstructed, concrete wall, or steel electrical enclosure: Up to 3.5m
 |  
            | Temperature | Operating: -10 °C to 50 °C Storage: -40 °C to 60 °C
 |  
            | Temperature coefficient | 0.1 X (specified accuracy) /°C (<18 °C or >28 °C) |  
            | Relative humidity | 0 % to 90 % (0 °C to 35 °C), 0 % to 75 % (35 °C to 40 °C), 0 % to 45 % (40 °C to 50 °C) |  
            | Altitude | Operating: 2,000 m Storage: 12,000 m
 |  
            | Electromagnetic compatibilty EMI, RFI, EMC, RF | EN 61326-1:2006, EN 61326-2-2:2006. ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249, FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE |  
            | Safety compliance | ANSI/ISA 61010-1 / (82.02.01): 3 rd edition CAN/CSA-C22.2 No 61010-1-12: 3 rd edition
 UL 61010-1: 3 rd edition
 IEC/EN 61010-1:2010
 |  
            | Certifications | CSA, FCC, CE |  
            | Ingress Protection (IP) rating | IP54 |  
            | Pollution Degree | 2 |  
            | Size (H x W x L) | 4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in) |  
            | Weight | 340 g (12 oz) |    
    
        
            | Multimeters Template |  
            | Type | Digital |  
            | Style | Hand-Held |  
            | Measures AC V | Yes |  
            | Measures DC V | Yes |  
            | Measures AC A | Yes |  
            | Measures DC A | Yes |  
            | Maximum Voltage AC | 1000 V |  
            | Minimum Voltage AC | 0.1 mV |  
            | Resolution AC Volts | 0.1 mV |  
            | Maximum Voltage DC | 1000 V |  
            | Minimum Voltage DC | 0.1 mV |  
            | Resolution DC Volts | 0.1 mV |  
            | Maximum Current AC | 400 mA (0.4 A) |  
            | Minimum Current AC | 0.01 mA |  
            | Resolution AC Current | 0.01 mA |  
            | Maximum Current DC | 400 mA (0.4 A) |  
            | Minimum Current DC | 0.01 mA |  
            | Resolution DC Current | 0.01 mA |  
            | Basic Accuracy V DC | 0.09 % + 2 |  
            | Backlight | Yes |  
            | Dual Display | Yes |  
            | Analog Bargraph on Display | No |  
            | Decibels | Yes |  
            | Resistance | Yes |  
            | Frequency | Yes |  
            | Capacitance | Yes |  
            | Temperature | Yes |  
            | Diode Testing | Yes |  
            | CAT Rating | III |  
            | CAT Voltage | 1,000 V, 600 V |  
            | Intrinsically Safe | No |  
            | Kelvin 4-Wire Measurement Capability | No |  
            | Wireless Display | No |  
         
            | Unique Features | The Fluke 3000 FC Series Wireless Multimeter with the Fluke Connect™ app has all the essentials for convenient test and measurement troubleshooting: 
 AC and DC voltage measurements to 1000V.
 AC and DC current with 0.01 mA resolution.
 Continuity, resistance, diode test, capacitance and frequency measurements.
 MIN/MAX recording.
 CAT III 1000 V, Cat IV 600 V; IP54.
 
 With the Fluke t3000 FC Wireless K-Type Temperature Module you can:
 
 Use as a standalone meter or as part of the system.
 Logging function for recording and saving up to 65,000 readings.
 |  
            | Warranty | 1 YEARS |  
            | Power Supply Voltage | Battery Powered |  
            | Safety Approval | UL |  
            | Data Logging | Yes |  
            | Interfaces I/O | Bluetooth, Other, Wifi |  
            | IP Rating | IP54 |  
            | Product Weight | 3.49 LBS |  
            | Product Height | 10 IN |  
            | Product Length | 10.5 IN |  
            | Product Width | 4.25 IN |  
            | Shipping Weight | 3.84 LBS |  
            | Country of Origin | United States |  
            | UPC | 095969724227 |  |  
				 |  
     |  |