				Megger MIT30
                
                
                
 			 
				Catalog #: MIT30
30-kV High Voltage Insulation Tester
 
 
                
                    OverviewSpecificationsSummaryAccessories 	
                    
				        
                          Product Highlights 
    Continuously variable test voltage, 0 – 30kVOutput voltage accuracy, + 1.5% (full scale)User selectable current trip point, 0 - 360 µAmpBuilt-in adjustable ionization indicatorFail-safe grounding and “zero-start” switchesRugged field constructionCompact, lightweight, and portableBacklit, high-contrast LCDRobust, bright LEDs visible in direct sunlightEasy to operateHighly Accurate and Stable Output VoltageWide input power range, with optional DC battery moduleAdjustable ionization indicatorFast charging of high-capacitance samplesCurrent guard circuit for highly accurate measurementsIntegrated air transport pressure relief valveIntegrated carrying handle   Each Unit Includes 
    HV triaxial output cable, 3 mInput Power cordInstruction manual 
                          
    
        
            | Basic Specifications |  
            | Input |  
            | Voltage | 85 - 264 Vac, 110 - 350 Vdc, optional 24 Vdc battery pack |  
            | Frequency | dc, 47 - 440 Hz |  
            | Maximum Current | 680 mA, 85 - 264 Vac |  
            | Fusing | Double pole 5 x 20 mm ceramic 3A slow-blow fuse |  
            | Power Inlet | C14 acc. to IEC/EN 60320-1 |  
            | Output |  
            | Voltage | 0 to 30 kV |  
            | Maximum Current | 330 µA |  
            | Peak-Peak Ripple | <0.4% |  
            | Line Regulation | 0.03% |  
            | Load Regulation | 0.001% |  
            | Stored Energy | <50 mJ |  
            | Test Connection | 3m triaxial cable (HV, guard and current sense) terminated with DolphinTM clips |  
            | Control |  
            |  | ON/OFF switch integrated with power inlet and fuse holder High-voltage power supply control switch
 Rotary high-voltage control with integrated zero-start switch
 High-voltage warning lamp (daylight visible RED LED)
 Ready lamp (daylight visible GREEN LED)
 |  
            | Volt meter | backlit LCD, 10 V resolution, ±1.5 V full-scale accuracy |  
            | Current meter | backlit LCD, 100 nA resolution, ±300 nA accuracy |  
            | Overcurrent trip | single-turn pot, 0-120% of rated output |  
            | Audio ionization | indicator with volume control and integrated switch |  
            | Safety |  
            |  | 33 MW fail-safe internal discharge switch Integrated zero-start switch
 High-voltage warning lamp
 High strength plastic case
 Air transport pressure relief valve
 |  
            | Mechanical |  
            | Dimensions | 14 L x 12 L x 8 D in. (360 L x 304 W x 194 D mm) |  
            | Weight | 22 lb (10 kg) |  
            |  | Tough rotary molded plastic case Light weight aluminum panel
 Carrying handle
 Air transport pressure relief
 |  
            | Environmental |  
            | Operating Temperature | 14o F to 131o F (-10o C to +55o C) |  
            | Storage Temperature | -4o F to +158o F (-20o C to +70o C) |  
            | Humidity | 0 to 90% RH (non-condensing) |  
            | IP Rating | IP67 when closed for transport (Def Stan 81-41/STANAG 4280) IP52 when in use
 |  
            | Maximum Altitude (full rating) | 1600 m (MSL) |  
            | Regulatory Compliance |  
            | EMC | Compliant to IEC61326, Table 1, criterion A for immunity Compliant to IEC61326, Table 4, class B for emissions
 |  
            | Safety | Compliant to IEC61010-1 2001 |    
    
        
            | Micro / Milli / Meg Ohmmeters/Megohmmeter / Insulation Resistance Testers Template |  
            | Type | Line |  
            | IR Test Voltage | 100 V, 25V |  
            | Variable Incremental Voltage | Yes |  
            | Continuity Test | No |  
            | Live Circuit Voltage Detection | No |  
            | Automated Test Results | Other |  
            | Power Supply | Line Powered |  
            | Timer | No |  
         
            | Unique Features | Used to perform HV insulation tests (proof/hi-pot tests) on insulating material where low levels of leakage current, down to an accuracy of 100 nA. need to be measured. 
 Test inhibit:
 If more than 50 volts is detected,
 testing will be inhibited.
 |  
            | Warranty | 12 MONTHS (1 YEARS) |  
            | Calibration Included | None |  
            | Power Supply Voltage | 120V/220V Universal |  
            | Data Logging | No |  
            | IP Rating | IP67 |  
            | Product Weight | 22 LBS |  
            | Product Height | 194 IN |  
            | Product Length | 360 IN |  
            | Product Width | 304 IN |  
            | Shipping Weight | 30 LBS |  
            | ECCN Number | EAR99 |  
            | Country of Origin | United States |  |  
					
				 
					
                
        
        
              Accessories
            
            
                
                        
                            | Product | Price |  
                            |  | Megger CB101 
                                    Catalog #: 6311-077
Calibrated Check Box for 5kV Insulation Tester | $1,045.23
 
 |  
				 |  
     |  |