				Megger DET4TC2 + Clamps
                
                
                
 			 
				Catalog #: 1000-365
4-Terminal Ground Resistance Tester with ICLAMP, VCLAMP, Field Calibrator
 
 
                
                    OverviewSpecificationsSummaryAccessories 	
                    
				        
                        Product Highlights
    Extended test range to 200 kΩUser selectable test frequency and voltage2, 3 and 4 point testing at the turn of a switchAttached Rod Technique (ART) enabledStakeless measurements enabledSimple one button operationAutomatic circuit checkingBacklit displayWeather and dust proof to IP54Complete with lead and stakes packed in a hard wearing carry caseDelivered with a FREE calibration certificate Version 2 Changes: 
    Range extended from 20k Ohm to 200k OhmUser selectable variable test frequency added. Each Unit Includes
    1 - DET4TC2 Ground Resistance Tester (1000-365)4 - Right-Angle Terminal Adapters1 - Hard Carrying Case4 - Test Leads (49 ft, 33 ft, 33 ft, 10 ft)1 - Set of Spikes1 - Field Calibrator1 - ICLAMP1 - VCLAMP8 - AA Alkaline Batteries1 - Certificate of Calibration 
                          
    
        
            | Resistance range | 0.01Ω to 200kΩ autoranging |  
            | Analog model | 2.5% of scale length |  
            | Digital models | 2P measurements 2% ±3 digits 3P measurements 2% ±3 digits
 4P measurements 2% ±3 digits
 ART measurements 5% ±3 digits
 Stakeless measurements 7% ±3 digits
 |  
            | Maximum probe resistance | Rp limit: 100k½ (50V output voltage) Rc limit: 100k½ (50V output voltage)
 Limits reduced to 50k½ for 25V output voltage
 Limits reduced to 5k½ for 0.01 ½ resolution
 |  
            | Earth voltage range | 0 – 100 V |  
            | Earth voltage accuracy | 2% ±2 V |  
            | 2-wire test | Yes, all models |  
            | 3-wire test | Yes, all models |  
            | 4-wire test | DET4TD, DET4TC2, DET4TCR2 |  
            | ART (Attached Rod Technique) | DET3TC, DET4TC2 and DET4TCR2 |  
            | Ground current range (with current measuring clamp) | 0.5 mA to 19.9 A |  
            | Ground current accuracy | 5% ±3 digits |  
            | Display | LCD (moving coil meter for analog model) |  
            | Test frequency | 128 Hz |  
            | Test voltage | 25 V or 50 V, user selectable (factory setting 50 V) |  
            | Test current | 450 micro-amps at 25 V or 50 V (selectable), 4.5mA at 25 V |  
            | Noise rejection | 40V pk to pk |  
            | Noise check | Automatic (by selector switch DET3TA) |  
            | C spike check | Automatic (by pushbutton DET3TA) |  
            | P spike check | Automatic (by pushbutton DET3TA) |  
            | Maximum current loop resistance | 100 k-ohms at 50V, 50 k-ohms at 25 V and 5 k-ohms for 0.01 ohm resolution for readings below 19 ohms |  
            | Maximum voltage probe resistance | 100 k-ohms at 50V, 50 k-ohms at 25 V and 5 k-ohms for 0.01 ohm resolution for readings below 19 ohms |  
            | Battery type | 8 1.5 V AA cells (8 1.5 V AA NiMH rechargeable cells – DET4TCR2) |  
            | Battery life | 3 hours, 700 consecutive tests |  
            | Safety | EN61010-1 CAT IV 100 V |  
            | Terminals | 4 mm plug type (test leads) |  
            | Ingress protection | IP54 |  
            | EMC | Meets the requirements of EN61326-1:1998 for use in heavy industrial areas |  
            | Dimensions | 8 x 5.7 x 3.2 in. (203 x 148 x 78 mm) |  
            | Weight | 2.2 lb (1 kg) |  
            | Operating temperature range | -.5º to +131º F (-15º to +55º C); DET3TA: -4º to +122º F (-20º to +50º C) |  
            | Storage temperature range | -40º to +158º F (-40º to +70º C) |  
            | Humidity | 95% RH non-condensing at 104º F (40º C) 
 |    
    
        
            | Ground Testers/3 Pole / 4 Pole Ground Testers Template |  
            | Type | 4 Pole |  
            | Display (3 Pole Testers) | Digital |  
            | Ground Resistance Range | 200 K Ohms |  
            | Operating Frequency | 128 Hz |  
            | Accuracy | 2P measurements 2% ±3 digits 3P measurements 2% ±3 digits
 4P measurements 2% ±3 digits
 ART measurements 5% ±3 digits
 Stakeless measurements 7% ±3 digits
 |  
            | Measuring Current | 4.5 mA |  
            | Measuring Voltage | 50 V |  
            | Measuring Frequency | 128 Hz |  
            | Soil Resistivity | Yes |  
            | Stakeless Capability | Yes |  
            | CAT Rating | IV |  
            | Optional Ground Kit Included | No |  
            | Auto Ranging | No |  
         
            | Unique Features | Dry-cell battery powered 4-terminal tester with selectable test frequencies, greater measurement sensitivity and attached rod technique and stakeless measurement capability |  
            | Warranty | 2 YEARS |  
            | Calibration Included | NIST Calibration |  
            | Power Supply Voltage | Battery Powered |  
            | Data Logging | No |  
            | IP Rating | IP54 |  
            | Product Weight | 2.2 LBS |  
            | Product Height | 3.2 IN |  
            | Product Length | 8 IN |  
            | Product Width | 5.7 IN |  
            | ECCN Number | EAR99 |  
            | Country of Origin | United Kingdom |  |  
				 |  
     |  |