				Fluke Calibration 4180-156
                
                
                
 			 
				Catalog #: 3109516
Precision Infrared Calibrator, 152 MM (6IN), -15 TO 120C,115V
 
 
                
                    OverviewSpecificationsSummaryCasesAccessories 	
                    
				        
                        Product Highlights
    Calibrated radiometrically for meaningful, consistent results.Accredited calibration includedAccurate, reliable performance from –15 °C to 500 °CLarge 152 mm (6 in) target captures peripheral vision of IR thermometer for more accurate measurementsLight weight and convenient handle make it easy to transportIntuitive, easy-to-read display that indicates when temperature is stable.Reaches temperature set-point fast for ef?cient ?eld operationGuaranteed accuracy speci?cationsRadiometric calibration included for traceable best practice resultsExcellent stability and uniformity Each Unit Includes
    4180 IR CalibratorReport of Calibration (NVLAP Accredited)Power CordUser’s GuideGetting Started GuideDocumentation CDTarget CoverSerial Cable 
                        
    
        
            | Specifications |  
            |  | 4180 | 4181 |  
            | Temperature range (@ 23 °C ambient, 0.95 emissivity) | –15 °C to 120 °C | 35 °C to 500 °C |  
            | Display accuracy1 | ± 0.40 °C at –15 °C ± 0.40 °C at 0 °C
 ± 0.50 °C at 50 °C
 ± 0.50 °C at 100 °C
 ± 0.55 °C at 120 °C
 | ± 0.35 °C at 35 °C ± 0.50 °C at 100 °C
 ± 0.70 °C at 200 °C
 ± 1.20 °C at 350 °C
 ± 1.60 °C at 500 °C
 |  
            | Stability | ± 0.10 °C at –15 °C ± 0.05 °C at 0 °C
 ± 0.10 °C at 120 °C
 | ± 0.05 °C at 35 °C ± 0.20 °C at 200 °C
 ± 0.40 °C at 500 °C
 |  
            | Uniformity (5.0 in dia of center of target)2 | ± 0.15 °C at –15 °C ± 0.10 °C at 0 °C
 ± 0.25 °C at 120 °C
 | ± 0.10 °C at 35 °C ± 0.50 °C at 250 °C
 ± 1.00 °C at 500 °C
 |  
            | Uniformity (2.0 in dia of center of target)2 | ± 0.10 °C at -15 °C ± 0.10 °C at 0 °C
 ± 0.20 °C at 120 °C
 | ± 0.10 °C at 35 °C ± 0.25 °C at 250 °C
 ± 0.50 °C at 500 °C
 |  
            | Heating time | 15 min: –15 °C to 120 °C 14 min: 23 °C to 120 °C
 | 20 min: 35 °C to 500 °C |  
            | Cooling time | 15 min: 120 °C to 23 °C 20 min: 23 °C to –15 °C
 | 100 min: 500 °C to 35 °C 40 min: 500 °C to 100 °C
 |  
            | Stabilization time | 10 minutes |  
            | Nominal emissivity3 | 0.95 |  
            | Thermometer emissivity compensation | 0.9 to 1.0 |  
            | Target diameter | 0152.4 mm (6 in) |  
            | Computer interface | RS-232 |  
            | Power | 15 V ac (± 10%), 6.3 A, 50/60 Hz, 630 W
 230 V ac (± 10%), 3.15 A,
 50/60 Hz, 630 W
 | 115 V ac (± 10%), 10 A, 50/60 Hz, 1000 W
 230 V ac (± 10%), 5 A,
 50/60 Hz, 1000 W
 |  
            | Fuse(s) | 115 V ac 6.3 A, 250 V, slow blow 230 V ac 3.15 A, 250 V, T
 | 115 V ac 10 A, 250 V, fast blow 230 V ac 5 A, 250 V, F
 |  
            | Size (HxWxD) | 356 mm x 241 mm x 216 mm (14 in x 9.5 in x 8.5 in)
 | 356 mm x 241 mm x 216 mm (14 in x 9.5 in x 8.5 in)
 |  
            | Weight | 9.1 kg (20 lb) | 9.5 kg (21 lb) |  
            | Safety | EN 61010-1:2001, CAN/CSA C22.2 No. 61010.1-04 |  
            | 1For 8 µm to 14 µm spectral band thermometers with emissivity set between 0.9 and 1.0 2The uniformity specification refers to how IR thermometers with different spot sizes both focused at the center of the targer will measure the same temperature.
 3The target has a nominal emissivity of 0.95, however it is radiometrically calibrated to minimize emissivity related uncertainties.
 |  
    
        
            | Style (Infrared Calibrators) | Bench Top |  
            | Max Temperature | 500 C |  
            | Accuracy | ± 0.40 °C at –15 °C 
 ± 0.40 °C at 0 °C
 
 ± 0.50 °C at 50 °C
 
 ± 0.50 °C at 100 °C
 
 ± 0.55 °C at 120 °C
 |  
            | Stability | See note |  
            | Stabilization Time | 10 MIN |  
            | Digital Display (Infrared Calibrators) | Yes |  
            | RTD Reference Temperature | Yes |  
            | Fixed Emissivity | Yes |  
            | Spot Diameter | 6 IN (25.40 MM) |  
            | Heating Time | 15 MIN |  
            | Cooling Time | 20 MIN |  
            | Programmable | Yes |  
            | Unique Features | Rapid heating and cooling 
 RS-232 interface capability
 
 Temperature scan rate control
 
 Eight set-point memory
 
 Adjustable readout in °C or °F
 
 Adjustable Emissivity
 |  
            | Warranty | 1 YEARS |  
            | Calibration Included | Factory Calibration |  
            | Power Supply Voltage | 120V/220V Universal |  
            | Safety Approval | CSA |  
            | Data Logging | No |  
            | Interfaces I/O | Analog Output, IR, RS-232, Analog Input |  
            | Product Weight | 20 LBS |  
            | Product Height | 14 IN |  
            | Product Length | 8.5 IN |  
            | Product Width | 9.5 IN |  
            | Shipping Weight | 26.5 LBS |  
            | Country of Origin | United States |  
            | Shipping Height | 18.9 IN |  
            | Shipping Length | 18.9 IN |  
            | Shipping Width | 18.9 IN |  
            | UPC | 095969441087 |  |  
				 |  
     |  |