				Fluke 771
                
                
                
 			 
				Catalog #: 2646347
Milliamp Process Clamp Meter
 
 
                
                    OverviewSpecificationsSummaryCasesAccessories 	
                    
				        
                        Product Highlights
    Best in class 0.2 % accuracy0.01 mA resolution and sensitivityMeasure 4 to 20 mA signals without ”breaking the loop”Measure mA signals for PLC and control system analog I/ODual backlit display with both mA measurement and percent of 4 to 20 mA spanMeasurement Spotlight illuminates hard to see wires in dark enclosuresDetachable clamp with extension cable for measurements in tight locationsMeasure 10 to 50 mA signals in older control systems using the 99.9 mA rangeAutomatically change the 4 to 20 mA output for remote testingPower saving features, auto-off, backlight timeout extend battery lifeHold function captures and displays changing measurements Each Unit Includes
    Soft Carrying CaseUsers Manual 
                          
    
        
            | Diameter of measurable conductor | 0.177” or 4.5 mm max |  
            | Operating temperature | -10 to 50 ºC |  
            | Storage Temperature | -25 to 60ºC |  
            | Operating Humidity | < 90% @ <30 ºC, < 75% @ 30 to 55ºC |  
            | Operating Altitude | 0 to 2000 m |  
            | IP Rating | IP 40 |  
            | Size | 59 x 38 x 212 mm, (2.32 x 1.5 x 8.35 in.) |  
            | Weight | 260G, (9.1 oz.) |  
            | Vibration | Random 2 g, 5 to 500 Hz |  
            | Shock | 1 meter drop test (except the jaw) |  
            | EMI/RFI | Meets EN61326-1 Note: For current measurement w/ JAW, add 1mA to specification for EMC field strengths of 1V/m up to 3V/m.
 |  
            | Temperature Coefficient | 0.01% ºC (<18ºC or > 28ºC) |  
            | Power, battery life | (2) AA 1.5 V Alkaline, IEC LR6, 40 hours typical |  
            | Warranty | Three years for electronics; One year for cable and clamp assembly |  
            | mA measurement (Measured by clamp)
 | Resolution and Range | 0 to 20.99 mA |  
            | Accuracy | 0.2% +2 counts |  
            | Resolution and Range | 21.0 mA to 100.0 mA |  
            | Accuracy | 1% + 5 counts |    
    
        
            | Clamp Meters/Clamp Meters Template |  
            | Type | Milliamp Process Clamp Meter |  
            | True RMS | No |  
            | Maximum Current DC | 100 mA (0.1 A) |  
            | Minimum Current DC | 10 mA |  
            | Basic Voltage Accuracy | .2% |  
            | Digits Display | 3.5 |  
            | Resolution DC Current | 0.01 mA (0.00001 A) |  
            | Maximum Conductor Size | 0.177 IN |  
            | Auto Ranging/Manual | Manual |  
            | Auto Power Off | Yes |  
            | Detachable Jaw | Yes |  
            | Rotating Jaw / Swivel | No |  
            | Peak Hold | No |  
            | Min/Max | No |  
            | In-Rush Current | No |  
            | Dual Display | Yes |  
            | Analog Bargraph on Display | No |  
            | Backlight | Yes |  
            | Remote Display | No |  
            | Resistance | No |  
            | Frequency | No |  
            | Continuity | No |  
            | Capacitance | No |  
            | Temperature (K T/C) | No |  
            | Temperature (IR Sensor) | No |  
            | Diode Testing | No |  
            | Overload Protector | Yes |  
            | True Power (KW) | No |  
            | Apparent Power (VA) | No |  
            | Power Factor (PF) | No |  
            | Single Phase/Three Phase | Single Phase |  
            | Crest Factor | No |  
            | Energy (KWh) | No |  
            | Reactive Power (KVAR) | No |  
            | Source/Simulate (Process Clamp) | No |  
            | Process / Calibration/Signal Calibrators/Loop Calibrators Template |  
            | Measure Inputs | Yes |  
            | Source Outputs | Yes |  
            | Display (Loop Calibrators) | Dual |  
            | Maximum Current | 99.9 mA (0.100 A) |  
            | Current Measurement Resolution | 0.01mA |  
            | Current Accuracy | 0.2% |  
            | Measure RTD | No |  
            | Measure T/C | No |  
            | Measure Resistance | No |  
            | Measure Frequency | No |  
            | Measure Thermistor | No |  
            | Programmable | No |  
            | Auto Step/Ramp | No |  
            | Hart Compatible | No |  
            | Battery Life | 12 HR |  
            | Intrinsically Safe | No |  
            | Process / Calibration/Milliamp Calibrators Template |  
            | Source/Simulate DC Current | Yes |  
            | Measure DC Current | Yes |  
            | Two Wire Transmitter Simulation | No |  
            | Percent Display | Yes |  
            | Accuracy | 0 to 20.99 mA: 0.2%+2 counts 21.0 mA to 100.0 mA: 1%+5 counts
 |  
            | Simulate Loop Voltage | No |  
            | Ramp/Step Output | Yes |  
            | FieldBus Compatible | No |  
         
            | Data Logging | No |  
            | Unique Features | Best in class 0.2 % accuracy. 0.01 mA resolution and sensitivity.
 Measure 4 to 20 mA signals without ”breaking the loop”.
 Measure mA signals for PLC and control system analog I/O.
 Dual backlit display with both mA measurement and percent of 4 to 20 mA span.
 Measurement Spotlight illuminates hard to see wires in dark enclosures.
 Detachable clamp with extension cable for measurements in tight locations.
 |  
            | Warranty | 3 YEARS |  
            | Warranty Details | One-year on mA clamp assembly and cable. |  
            | Calibration Included | None |  
            | Power Supply Voltage | Battery Powered |  
            | IP Rating | IP40 |  
            | Product Weight | 1.21 OUNCES (0.076 LBS) |  
            | Battery Type | AA |  
            | Product Height | 2.83 IN |  
            | Product Length | 9.29 IN |  
            | Product Width | 4.33 IN |  
            | Shipping Weight | 1.33 LBS |  
            | Country of Origin | China |  
            | Shipping Height | 2.83 IN |  
            | Shipping Length | 9.29 IN |  
            | Shipping Width | 4.33 IN |  
            | UPC | 095969349697 |  
            | CA Residents | Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov |  |  
					
                
        
        