				Fluke I2000 FLEX
                
                
                
 			 
				Catalog #: 2584912
FLEX Current Clamp Adaptor
 
 
                
                	
                    
				        
                        Product Highlights
    Three ranges: 20A, 200 A & 2000 A, 100 mV/A, 10 mV/A & 1 mV/A outputIdeal for current measurement on thick and hard to reach conductors without breaking the circuitMaximum conductor diameter 178 mmCAT III 600V safety ratingCountry of Origin China 
                        
    
        
            | Electrical specifications |  
            | Current ranges | 20 A 200 A
 2000 A
 AC rms
 |  
            | Output sensitivity (AC-coupled) | 1 mV 10 mV
 100 mV
 1 mV per A
 |  
            | Load impedance | 100 kO minimum |  
            | Accuracy | at +25°C ±1% of range (45 Hz to 65 Hz)
 |  
            | Linearity | 10% to 100% of range ±0.2% of reading
 |  
            | Noise | 8 mV AC rms (30 A) 2 mV AC rms (300 A, 3000 A)
 |  
            | Frequency range | 10 Hz to 20 kHz (-3 dB) |  
            | Phase error | < ±1° (45 Hz to 65 Hz) ±10° (at 20 kHz)
 |  
            | Position sensitivity | with cable > 25 mm from the coupling ±2% of range
 |  
            | External field | with cable > 200 mm from the head ±1% of range
 |  
            | Power supply | 2 x AA/MN 1500/LR6 Alkaline, 200 hours, low battery indicator |  
            | Temperature Coefficient | ±0.08% of reading per °C |  
            | Working voltage | see Safety standards section 600 V AC rms or DC
 |  
            | General Specifications |  
            | Head Circumference | 610 mm (24 in) |  
            | Head cable diameter | 14.3 mm (0.56 in) |  
            | Head bend radius | 38.1 mm (1.5 in) |  
            | Cable length (head to electronics) | 2 m (6.56 ft) |  
            | Output connection | Molded 4 mm safety plugs (not integrated) |  
            | Operating temperature range | 0°C to +70°C (32°F to 158°F) (head and electronics) |  
            | Storage temperature range | -40°C to +105°C (-40°F to 221°F) (head) -20°C to +85°C (-4°F to 185°F) (electronics)
 |  
            | Operating humidity | 15% to 85% (non-condensing) |  
            | Weight | 180 g (6.34 oz) (head) 190 g (6.70 oz) (electronics)
 |  
            | Safety standards | EN 61010-031: 2002 EN 61010-2-032: 2002
 EN 61010-1: 2001
 600 Vrms, Category III, Pollution Degree 2
 Use of the probe on uninsulated conductors is limited to 600 V ac rms or dc and frequencies below 1 kHz.
 |  
            | EMC standards | EN 61326: 1998 +A1, A2, and A3 |  
            | Dimensions (H x W x D) | 116 x 68.5 x 30 mm (4.56 x 2.69 x 1.18 in) |  |  
					
				 
					
				 
				 |  
     |  |