				Fluke 80T-150UA
                
                
                
 			 
				Catalog #: 3190456
Universal Temperature Probe
 
 
                
                	
                    
				        
                        Product Highlights
    Compatible with Fluke DMMHigh accuracy, fast reading for low voltage (below 24 V AC, 60 V DC) applicationsMeasurement range: -50 to 150°COutput: 1 mV/°C or 1 mV/°F (switchable)One year warrantyCountry of Origin Taiwan  
                          
    
        
            | General |  
            | Weight | 150 g (5.3 oz) |  
            | Overall Length | 53.8 inch (1.36 m) |  
            | Battery | Standard 9 V battery (NEDA #1604,6F22,006P) |  
            | Battery Life | 600+ hours, typical (Alkaline Battery), 6.5 V minimum |  
            | Output Termination | Standard 0.75-inch spaced double banana plug |  
            | Probe Material | Glass-filled valox |  
            | Probe Size | 0.6 inch maximum diameter |  
            | Tip Material | Nickle Plated Copper |  
            | Tip Size | 0.31 cm (0.12 inch diameter) |  
    
        
            | Electrical |  
            | Measurement Range | -50 to +150 °C -58 to +302 °F
 |  
            | Sensitivity (80T-150UA output) | 1 mV dc / °C or °F |  
            | Voltage Standoff | 60 V dc or 30 V ac rms (42.4 V peak) |  
            | Settling Time | 9.5 seconds to settle within 2 ° for a 50 ° change |  
            | RF Field | The 80T-150UA product is unspecified in environments with EMC fields greater than 100 mV/meter. ESD performance is specified as Criteria C per EN61326. |  
    
        
            | Environmental |  
            | Ambient Operating Range for Temperature Module | 0 to +50 °C (+32 to +122 °F) |  
            | Maximum Temperature Probe Body and Cable | +70 °C (+160 °F) See Probe Limitations |  
            | Maximum Temperature Probe Body and Cable | +70 °C (+160 °F) See Probe Limitations |  
            | Minimum Temperature Probe Body and Cable |  
            | Minimum Operating Temperature for Cable | -12 °C (+10 °F) |  
            | Minimum Operating Temperature for Probe Body | -40 °C (-40 °F) See Probe Limitations |  
            | Storage Temperature for Unit | -40 to +70 °C (-40 to +160 °F) |  
            | Humidity | 0 % to 90 % (0 °C to +35 °C) 0 % to 70 % (+35 °C to +50 °C) (noncondensing)
 |  
            | Altitude | Operating: =3048 m ( =10,000 ft) |  
            | Storage | ≤15240 m (=50,000 ft) |  
            | Application Force | 15 pounds maximum (probe tip to measured surface) |  
    
        
            | Accuracy (Applies for one year after purchase or calibration) |  
            | AMBIENT °C | ACCURACY |  
            | +15 to +35 °C | ±1 °C from 0 to +100 °C, decreasing linearly to ±3 °C at -50 and +150 °C |  
            | 0 to +15 °C and +35 to +50 °C | ±2 °C from 0 to +100 °C, decreasing linearly to ±4 °C at -50 and +150 °C |  
            | AMBIENT °C | ACCURACY |  
            | +59 to +95 °F | ±1.8 °F from +32 to +212 °F, decreasing linearly to ±5.4 °F at -58 and +302 °F |  
            | +32 to +59 °F and +95 to +122 °F | ±3.6 °F from +32 to +212 °F, decreasing linearly to ±7.2 °F at -58 and +302 °F |  |  
					
				 
					
				 
				 |  
     |  |