				Fluke Calibration 9143-E-156
                
                
                
 			 
				Catalog #: 3054760
Field Metrology Well with 9143-INSE
 
 
                
                    OverviewSpecificationsSummaryCasesInserts 	
                    
				        
                        Product Highlights
    Cool to –25 °C in 15 minutes and heat to 660°C in 15 minutesBuilt-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA currentTrue reference thermometry with accuracy to ±0.01 °CLightweight, portable, and fastOn-board automation and documentationMetrology performance in accuracy, stability, uniformity, and loading Each Unit Includes
    9143 Field Metrology Well9143-INSX Insert (X = A,B.C,D,E, or F)Power CordRS-232 CableUser GuideTechnical Manual CDReport Calibration and calibration label. Accredited ISO17025 CalibrationWell Insulator9930 Interface-it Software and User's Guide 
                        
    
        
            | Base Unit Specifications |  
            | Temperature Range at 23 °C | 9142 –25 °C to 150 °C (–13 °F to 302 °F) 9143 33 °C to 350 °C (91 °F to 662 °F)
 9144 50 °C to 660 °C (122 °F to 1220 °F)
 |  
            | Display Accuracy | 9142 ± 0.2 °C Full Range 9143 ± 0.2 °C Full Range
 9144 ± 0.35 °C at 50 °C
 ± 0.35 °C at 420 °C
 ± 0.5 °C at 660 °C
 |  
            | Stability | 9142 ± 0.01 °C Full Range 9143 ± 0.02 °C at 33 °C
 ± 0.02 °C at 200 °C
 ± 0.03 °C at 350 °C
 9144 ± 0.03 °C at 50 °C
 ± 0.04 °C at 420 °C
 ± 0.05 °C at 660 °C
 |  
            | Axial Uniformity at 40 mm (1.6 in) | 9142 ± 0.05 °C Full Range 9143 ± 0.04 °C at 33 °C
 ± 0.1 °C at 200 °C
 ± 0.2 °C at 350 °C
 9144 ± 0.05 °C at 50 °C
 ± 0.35 °C at 420 °C
 ± 0.5 °C at 660 °C
 |  
            | Radial Uniformity | 9142 ± 0.01 °C Full Range 9143 ± 0.01 °C at 33 °C
 ± 0.015 °C at 200 °C
 ± 0.02 °C at 350 °C
 9144 ± 0.02 °C at 50 °C
 ± 0.05 °C at 420 °C
 ± 0.10 °C at 660 °C
 |  
            | Loading Effect (with a 6.35 mm reference probe and three 6.35 mm probes) | 9142 ± 0.006 °C Full Range 9143 ± 0.015 °C Full Range
 9144 ± 0.015 °C at 50 °C
 ± 0.025 °C at 420 °C
 ± 0.035 °C at 660 °C
 |  
            | Hysteresis | 9142 0.025 9143 0.03
 9144 0.1
 |  
            | Operating Conditions | 0 °C to 50 °C, 0 % to 90 % RH (non-condensing) |  
            | Environmental Conditions (for all specifications except temperature range) | ± 1.0 % RH for ± 5 % changes within 20 % RH to 70 % RH |  
            | RH Resolution | 13 °C to 33 °C |  
            | Immersion (Well) Depth | 150 mm (5.9 in) |  
            | Insert OD | 9142 30 mm (1.18 in) 9143 25.3 mm (1.00 in)
 9144 24.4 mm (0.96 in)
 |  
            | Heating Time | 9142  16 min: 23 °C to 140 °C 23 min: 23 °C to 150 °C
 25 min: –25 °C to 150 °C
 9143  5 min: 33 °C to 350 °C
 9144  15 min: 50 °C to 660 °C
 |  
            | Cooling Time | 9142 15 min: 23 °C to –25 °C 25 min: 150 °C to –23 °C
 9143 32 min: 350 °C to 33 °C
 14 min: 350 °C to 100 °C
 9144 35 min: 660 °C to 50 °C
 25 min: 660 °C to 100 °C
 |  
            | Resolution | 0.01 ° |  
            | Display | LCD, °C or °F user-selectable |  
            | Size (H x W x D) | 290 mm x 185 mm x 295 mm (11.4 x 7.3 x 11.6 in) |  
            | Weight | 9142 8.16 kg (18 lb) 9143 7.3 kg (16 lb)
 9144 7.7 kg (17 lb)
 |  
            | Power Requirements | 9142 100 V to 115 V (± 10 %) 50/60 Hz, 635 W 230 V (± 10 %) 50/60 Hz, 575 W 9143 100 V to 115 V (± 10 %), 50/60 Hz, 1400 W 230 V (± 10
 9144 %), 50/60 Hz, 1800 W
 |  
            | Computer Interface | RS-232 and 9930 Interface-it control software included |  
            | -P Specifications |  
            | Built-in Reference Thermometer Readout Accuracy (4-Wire Reference Probe)† | ± 0.010 °C at -25 °C ± 0.015 °C at 0 °C
 ± 0.020 °C at 50 °C
 ± 0.025 °C at 150 °C
 ± 0.030 °C at 200 °C
 ± 0.040 °C at 350 °C
 ± 0.050 °C at 420 °C
 ± 0.070 °C at 660 °C
 |  
            | Reference Resistance Range | 0 ohms to 400 ohms |  
            | Reference Resistance Accuracy‡ | 0 ohms to 42 ohms: ±0.0025 ohms 42 ohms to 400 ohms: ±60 ppm of reading |  
            | Reference Characterizations | ITS-90, CVD, IEC-751, Resistance |  
            | Reference Measurement Capability | 4-wire |  
            | Built-in RTD Thermometer Readout Accuracy | NI-120: ± 0.015 °C at 0 °C PT-100 (385): ± 0.02 °C at 0 °C
 PT-100 (3926): ± 0.02 °C at 0 °C
 PT-100 (JIS): ± 0.02 °C at 0 °C
 |  
            | RTD Resistance Range | 0 ohms to 400 ohms |  
            | RTD Resistance Accuracy‡ | 0 ohms to 25 ohms: ±0.002 ohms 25 ohms to 400 ohms: ±80 ppm of reading
 |  
            | RTD Characterizations | PT-100 (385),(JIS),(3926), NI-120, Resistance |  
            | RTD Measurement Capability | 4-wire RTD (2-,3-wire RTD w\ Jumpers only) |  
            | RTD Connection | 4 terminal input |  
            | Built-in TC Thermometer Readout Accuracy | Type J: ± 0.7 °C at 660 °C Type K: ± 0.8 °C at 660 °C
 Type T: ± 0.8 °C at 400 °C
 Type E: ± 0.7 °C at 660 °C
 Type R: ± 1.4 °C at 660 °C
 Type S: ± 1.5 °C at 660 °C
 Type M: ± 1.4 °C at 660 °C
 Type L: ± 0.7 °C at 660 °C
 Type U: ± 0.75 °C at 600 °C
 Type N: ± 0.9 °C at 660 °C
 Type C: ± 1.1 °C at 660 °C
 |  
            | TC Millivolt Range | –10 mV to 75 mV |  
            | Voltage Accuracy | 0.025% of reading + 0.01 mV |  
            | Internal Cold Junction Compensation Accuracy | ± 0.35 °C (ambient of 13 °C to 33 °C) |  
            | TC Connection | Small connectors |  
            | Built-in mA Readout Accuracy | 0.02 % of reading + 2 mV |  
            | mA Range | Cal 4-22 mA, Spec 4-24 mA |  
            | mA Connection | 2 terminal input |  
            | Loop Power Function | 24 V DC loop power |  
            | Built-in Electronics Temperature Coefficient (0 °C to 13 °C, 33 °C to 50 °C) | ± 0.005 % of range per °C |  
            | † The temperature range may be limited by the reference probe connected to the readout. The Built-In Reference Thermometer Readout Accuracy does not include the sensor probe accuracy. It does not include the probe uncertainty or probe characterization errors.C ‡ Measurement accuracy specifications apply within the operating range and assume 4-wires for PRTs. With 3-wire RTDs add 0.05 ohms to the measurement accuracy plus the maximum possible difference between the resistances of the lead wires. X in the above model numbers to be replaced with A, B, C, D, E, or F as appropriate for the desired insert. See the inserts illustration and listing below. |    
    
        
            | Calibration Baths |  
            | Type | Dry |  
            | Min Temp (Caiibration Baths) | 33 C |  
            | Max Temp (Calibration Baths) | 350 C |  
            | Accuracy (Calibration Baths) | 0.2 C |  
            | Voltage (Calibration Baths) | 115 / 220 VAC, 115 VAC, 220 VAC |  
            | Special Features (Calibration Baths) | Inserts Available (Dry Baths), PC Software, Programmable Tests |  
         
            | Unique Features | The process versions of Field Metrology Wells have on-board non-volatile memory for documentation of up to 20 tests. Each test can be given a unique alphanumeric ID and will record block temperature, reference temperature, UUT values, error, date, and time. |  
            | Additional Info/Comments | All Field Metrology Wells allow for two types of automated thermostatic switch test procedures—auto or manual setup. Auto setup requires the entry of only the nominal switch temperature. |  
            | Calibration Included | Factory Calibration |  
            | Power Supply Voltage | 120V 50/60 Hz, 120V/220V Universal |  
            | Safety Approval | CSA |  
            | Data Logging | Yes |  
            | Interfaces I/O | RS-232 |  
            | Product Weight | 16 LBS |  
            | Product Height | 295 MM (11.61 IN) |  
            | Product Length | 290 MM (11.42 IN) |  
            | Product Width | 185 MM (7.28 IN) |  
            | ECCN Number | EAR99 |  
            | Country of Origin | United States |  |  
				 |  
     |  |