				Fluke I3000S FLEX-36
                
                
                
 			 
				Catalog #: 2584901
FLEX-36 AC Current Clamp 915mm
 
 
                
                    OverviewSpecificationsSummary 	
                    
				        
                        Product Highlights
    CAT III 600V safety ratingThree ranges: 30 A, 300 A & 3000 A, 1, 10 or 100 mV/A outputIdeal for current measurement on thick and hard to reach conductors without breaking the circuitMaximum conductor diameter 178 mm (7 in.) 
                          
    
        
            | Specifications |  
            | Current ranges | 30 A 300 A
 3000 A
 AC rms
 |  
            | Output sensitivity (AC-coupled) | 100 mV 10 mV
 1 mV per A
 |  
            | Load impedance | 100 kΩ minimum |  
            | Accuracy | at +25 °C ± 1 % of range (45 Hz to 65 Hz) |  
            | Linearity | 10 % to 100 % of range ± 0.2 % of reading |  
            | Noise | 8 mV ac rms (30 A) 2 mV ac rms (300 A, 3000 A)
 |  
            | Frequency range | 10 Hz to 20 kHz (-3 dB) |  
            | Phase error | < ± 1 º (45 Hz to 65 Hz) ± 10 º (at 20 kHz)
 |  
            | Position sensitivity | with cable > 25 mm from the coupling ± 2 % of range |  
            | External field | with cable > 200 mm from the head ± 1 % of range |  
            | Power supply | 2 x AA/MN 1500/LR6 Alkaline, , 400 hours, low battery indicator or dedicated external power supply |  
            | Temperature Coefficient | ± 0.08% of reading per°C |  
            | Working voltage | see Safety standards section 600 V AC rms or DC |  
            | General Specifications |  
            | Head Circumference | 610 mm (24 in) |  
            | Head cable diameter | 14.3 mm (0.56 in) |  
            | Head bend radius | 38.1 mm (1.5 in) |  
            | Cable length (head to electronics) | 2 m (6.56 ft) |  
            | Output connection | 0.5 m cable terminated with safety BNC connector. Supplied with 4mm safety plug adapter |  
            | Operating temperature range | -20 °C to +90 °C (-4 °F to 190 °F) (head) -20 °C to +85 °C (-4 °F to 185 °F) (electronics)
 |  
            | Storage temperature range | -40 °C to +105 °C (-40 °F to 221 °F) (head) -20 °C to +85 °C (-4 °F to 185 °F) (electronics)
 |  
            | Operating humidity | 15 % to 85 % (non-condensing) |  
            | Weight | 180 g (0.396 lb) (head) 190 g (0.419 lb) (electronics)
 |  
            | Safety standards | EN 61010-1: 2001 EN 61010-2-032: 2002
 EN 61010-031: 2002
 600 Vrms, Category III, Pollution Degree 2
 Use of the probe on uninsulated conductors is limited to 600 V ac rms or dc and frequencies below 1 kHz.
 |  
            | EMC standards | EN 61326: 1998 +A1, A2, & A3 |  
            | Maximum conductor size | 610 mm or 914 mm, depending on model |    
    
        
            | Clamp Meters/Current Clamp Adaptors / Current Clamps Template |  
            | Type (Current Clamp Adaptors | Flexible/Rogowski |  
            | Maximum Current | 3000 A |  
            | Current Output | No |  
            | Voltage Output | Yes |  
            | AC Current Only | Yes |  
            | AC/DC Current | No |  
            | Current Accuracy | ±1 % of range (45 – 65 Hz) |  
            | Phase Shift | < ±1° (45 – 65 Hz), ±10° (at 20 kHz) |  
            | CAT Rating | III |  
            | CAT Voltage Rating (V) | 600V |  
            | Connector | BNC |  
            | Style (Current Clamps) | Flex Probe (Rogowski) |  
            | Battery Powered | Yes |  
            | Externally Powered | Yes |  
         
            | Warranty | 1 YEARS |  
            | Power Supply Voltage | Battery Powered |  
            | Data Logging | No |  
            | Interfaces I/O | Analog Output |  
            | Product Weight | 0.4 LBS |  
            | Country of Origin | China |  |  
					
				 
					
				 
				 |  
     |  |