				Fluke I30
                
                
                
 			 
				Catalog #: 2584920
AC/DC Current Clamp Adaptor
 
 
                
                    OverviewSpecificationsSummary 	
                    
				        
                        Product Highlights
    The i30 current clamp is based on Hall Effect technology for use in measurement of both DC and AC currentThe i30 may be used in conjunction with multimeters, recorders and other suitable recording instruments for accurate non-intrusive current measurement 
                          
    
        
            | Electrical specifications |  
            | Specified current range | 30 mA to 30A dc, 30 mA to 20 A ac rms |  
            | Usable current range | 5 mA to 30 A dc, 30 mA to 20 A ac rms |  
            | Crest Factort | 1.4" |  
            | Lowest measurable current | 10 mA |  
            | Output sensitivity | 100 mV/A |  
            | Accuracy (at +25 °C) | ± 1 % of reading ± 2 mA |  
            | Resolution | ± 1 mA |  
            | Load impedance | > 10 k Ohms and ≤ 100pF |  
            | Conductor position sensitivity | ± 1 % relative to center reading |  
            | Frequency range | DC to 20 kHz (- 0.5 dB) |  
            | Temperature coefficient | ± 0.01 % of reading/°C |  
            | Power supply | 9 V Alkaline, MN1604/PP3, 30 hours, low battery indicator |  
            | Working voltage (see Safety Standards section) | 300 V ac rms or dc |  
            | General Specifications |  
            | Maximum conductor size | 19 mm diameter |  
            | Output connection | 4 mm safety connector |  
            | Output zero | Manual adjust via thumbwheel |  
            | Cable length | 1.5 meters |  
            | Operating temperature range | 0 °C to +50 °C |  
            | Storage temperature range (with battery removed) | -20 °C to +85 °C |  
            | Operating humidity | 15 % to 85 % (non-condensing) |  
            | Weight | 250 g |  
            | Safety standards | BS EN 61010-1:2001 BS EN 61010-2-032:2002
 BS EN 61010-031:2002
 300 Vrms, Category III, Pollution Degree 2
 Use of the probe on uninsulated conductors is limited to 300 V ac rms or dc and frequencies below 1 kHz.
 |  
            | EMC Standards | EN 61326: 1998 +A1, A2, & A3 |    
    
        
            | Clamp Meters/Current Clamp Adaptors / Current Clamps Template |  
            | Type (Current Clamp Adaptors | CT |  
            | Maximum Current | 30 A |  
            | Current Output | No |  
            | Voltage Output | Yes |  
            | AC Current Only | No |  
            | AC/DC Current | Yes |  
            | Maximum Conductor Size Fixed | 0.748 IN |  
            | CAT Rating | III |  
            | CAT Voltage Rating (V) | 300V |  
            | Connector | Banana |  
            | Style (Current Clamps) | Fixed |  
            | Battery Powered | Yes |  
            | Externally Powered | No |  
         
            | Warranty | 1 YEARS |  
            | Calibration Included | Factory Calibration |  
            | Power Supply Voltage | Battery Powered |  
            | Safety Approval | CE |  
            | Data Logging | No |  
            | Interfaces I/O | Analog Output |  
            | Product Weight | 0.55 LBS |  
            | Battery Type | 9v |  
            | Product Height | 1.0 IN |  
            | Product Length | 7.2 IN |  
            | Product Width | 2.8 IN |  
            | Shipping Weight | 3 LBS |  
            | Country of Origin | China |  |  
					
				 
					
				 
				 |  
     |  |