				Fluke Calibration P3224-BAR
                
                
                
 			 
				Catalog #: 4185527
Water Deadweight Tester Dual PCU, 700 BAR
 
 
                
                    OverviewSpecificationsSummarySoftwareAccessories 	
                    
				        
                        Product Highlights
    Water Operated – Dual PCUPressure Range 1 to 700 bar0.015% of reading accuracy standard (0.008% optional)Dual piston formatsBuilt-in hand pumps standardMounted spirit level with adjustable feetUnits can be trimmed to local gravity FOCPiston/cylinder design provides stability and repeatabilityHigh quality needle valves provide optimum controlMounted spirit level and adjustable feetTest station design with O-rings eliminates the need for PTFE tape or wrenchesImproved case with spring-loaded latches for hoodSturdy weight box with hinged lid and side handles for easy transport Each Unit Includes
    Deadweight Tester with weight setM14 x 1.5, M20 X 1.5, 1/8 inch, 1/4 inch, 3/8 inch and 1/2 inch NPT and BSP female adaptorsSpare sealsISO17025 Calibration Certificate with Data 
                        
    
        
            | Pressure ranges |  
            | Distilled water operated | Ranges to 10,000 psi (700 bar) |  
            | Accuracy | ±0.015% of reading (±0.008% optional) *Accuracy based on % of reading from 10% to 100% of the piston range when used in accordance with the corrections found on the calibration certificate. Below 10% ± (accuracy class) x 10% of the piston range.
 |  
            | Materials of construction |  
            | Standard weight material | Series 3 non-magnetic austenitic stainless steel |  
            | Weight density | 7.8 g/cm³ |  
            | Optional fractional weights | Solution heat treated aluminum |  
            | Weight density | 2.7 g/cm³ |  
            | Piston material | Tungsten carbide with nickel binder Density- 15.0 g/cm³
 |  
            | Cylinder material | Hardened martensitic steel Tungsten carbide (water above 500 psi, 35 bar)
 |  
            | Thermal coefficients of expansion | Oil piston/cylinder 16.5 ppm/°C Water (above 500 psi, 35 bar) 11 ppm/°C
 |  
            | General |  
            | Test port adaptors | 1/8, 1/4, 3/8 and 1/2 NPT or BSP
 |  
            | Instrument weight | 36 lbs (16 kg) |  
            | Instrument size | (W x D x H) 17.5 in x 12 in x 8.5 in (440 mm x 300 mm x 215 mm) |  
            | Mass set weight (typical) | 80 lbs (36 kg) |  
            | Reservoir volume | 150 cc |  
            | Screw press displacement | 5.5 cc |  
            | Pump displacement | 4.7 cc per stroke |  
            | O-ring seal materials | Buna N as standard, Viton and EPDM available |  
            | Weight increments |  
            | Minimum standard weight increments | Up to 500 psi (35 bar): 1 psi (0.1 bar) 500 to 5000 psi (35 to 350 bar): 10 psi (1 bar)
 5000 to 20,000 psi (350 to 1400 bar): 20 psi (2 bar)
 Model P3112: 1 psi (0.1 bar)
 |  
            | Optional Fractional Weights | Up to 500 psi (35 bar): 0.1 psi (0.01 bar) 500 to 5000 psi (35 to 350 bar): 1 psi (0.1 bar)
 5000 to 20,000 psi (350 to 1400 bar): 2 psi (0.2 bar)
 |  
            | Operating Fluids |  
            | Operating Fluids | Distilled or deionized water |  
            | Options |  
            | PressCal Software | Windows-based software program that allows users to easily apply all necessary corrections to enhance the deadweight tester performance. Calibration details are then stored and/or used to automatically create a calibration certificate. PressCal is provided as standard with all 0.008% instruments |  
            | Fluids | Instruments can be supplied for use with Skydrol or brake fluids. Due to the aggressive nature of these fluids the standard nitrile seals and the acrylic reservoir tube will be replaced by either Viton or EPDM seals (as applicable) and an aluminum reservoir tube. For these or any other specialty fluid applications, please consult the factory. |    
    
        
         
            | ECCN Number | EAR99 |  
            | Country of Origin | United States |  |  
				 |  
     |  |