				Fluke Calibration 1529-156
                
                
                
 			 
				Catalog #: 1672258
Chub-E4 Thermometer, 2 TC & 2 PRT/ Thermistor Inputs
 
 
                
                    OverviewSpecificationsSummaryCasesSoftwareAccessories 	
                    
				        
                        Product Highlights
    Four channels for PRTs, thermistors, and thermocouplesDisplays eight user-selected data fields from any channelLogs up to 8,000 readings with date and time stampsBattery provides eight hours of continuous operation Each Unit Includes 
    AC Adapter/Charger and Power CordUser ManualSerial CableReport of Calibration with Calibration Label2x Ferrites 
                        
    
        
            | Specifications |  
            |  | PRT / RTD | Thermistor | Thermocouple |  
            | Inputs | 2 channels PRT/thermistor and 2 channels TC, or 4 channels PRT/thermistor, or 4 channels TC, specify when ordering; PRT/thermistor channels accept 2, 3, or 4 wires; TC inputs accept B, E, J, K, N, R, S, T, and Au-Pt TC types. (Support for C and U type thermocouples is available. |  
            | Temperature Range | –189 °C to 960 °C | –50 °C to 150 °C | –270 °C to 1800 °C |  
            | Measurement Range | 0 to 400 W | 0 to 500 KW | –10 to 100 mV |  
            | Characterizations | ITS-90, IEC-751 (DIN “385”), Callendar-Van Dusen | Steinhart-Hart, YSI-400 | NIST Monograph 175, 3-point deviation function applied to NIST 175, 6th-order polynomial |  
            | Temperature Accuracy (meter only) | ± 0.004 °C at –100 °C ± 0.006 °C at 0 °C
 ± 0.009 °C at 100 °C
 ± 0.012 °C at 200 °C
 ± 0.018 °C at 400 °C
 ± 0.024 °C at 600 °C
 | ± 0.0025 °C at 0 °C ± 0.0025 °C at 25 °C
 ± 0.004 °C at 50 °C
 ± 0.010 °C at 75 °C
 ± 0.025 °C at 100 °C
 | Ext. RJC Int. RJC B at 1000 °C ± 0.6 °C ± 0.6 °C
 E at 600 °C ± 0.07 °C ± 0.25 °C
 J at 600 °C ± 0.1 °C ± 0.35 °C
 K at 600 °C ± 0.15 °C ± 0.4 °C
 N at 600 °C ± 0.15 °C ± 0.3 °C
 R at 1000 °C ± 0.4 °C ± 0.5 °C
 S at 1000 °C ± 0.5 °C ± 0.6 °C
 T at 200 °C ± 0.1 °C ± 0.3 °C
 |  
            | Temperature Resolution | 0.001 ° | 0.0001 ° | 0.01 to 0.001 ° |  
            | Resistance/Voltage Accuracy | 0 W to 20 W: ± 0.0005W 20 W to 400 W: ± 25 ppm of rdg | 0 W to 5 KW: ± 0.5 W 5 KW to 200 KW: ± 100 ppm of rdg. 200 KW to 500 KW ± 300 ppm of rdg. | –10 to 50 mV: ± 0.005 mV 50 to 100 mV: ± 100 ppm of rdg. Internal RJC: ± 0.25 °C) |  
            | Operating Range | 16 °C to 30 °C |  
            | Measurement Interval | 0.1 second to 1 hour; inputs may be read sequentially or simultaneously at 1 second or greater interval |  
            | Excitation Current | 1 mA, reversing | 2 and 10 µA, automatically selected | n/a |  
            | Display | 33 x 127 mm (1.3 x 5 in) backlit LCD graphical display |  
            | Display Units | °C, °F, K, W, KW, mV |  
            | Data Logging | Up to 8,000 time- and date-stamped measurements can be logged |  
            | Logging Intervals | 0.1, 0.2, 0.5, 1, 2, 5, 10, 30, or 60 seconds; 2, 5, 10, 30, or 60 minutes |  
            | Averaging | Moving average of most recent 2 to 10 readings, user selectable |  
            | Probe Connection | Patented DWF Connectors accept mini spade lug, bare-wire, or mini banana plug terminations | Universal receptacle accepts miniature and standard TC connectors |  
            | Communications | RS-232 included, IEEE-488 (GPIB) optional |  
            | AC Power | 100–240 V ac, 50-60 Hz, 0.4 A |  
            | DC Power | 12–16 VDC, 0.5 A (battery charges during operation from 14.5 to 16V DC, 1.0A) |  
            | Battery | NiMH, 8 hours of operation typical without backlight, 3 hours to charge, 500 cycles |  
            | Size (HxWxD) | 102 x 191 x 208 mm (4.0 x 7.5 x 8.2 in) |  
            | Weight | 2 kg (4.5 lb) |  
            | Calibration | Accredited NIST-traceable resistance calibration and NIST-traceable voltage calibration provided |  
    
        
         
            | Data Logging | Yes |  
            | Unique Features | Chub-E4 has four inputs for reading four different sensors simultaneously |  
            | Warranty Details | One-, two-, and four-year plans available
 |  
            | Additional Info/Comments | 2 channels PRT/thermistor and 2 channels TC, or 4 channels PRT/thermistor, or 4 channels TC, specify when ordering |  
            | Calibration Included | NIST Calibration |  
            | Power Supply Voltage | 120V 50/60 Hz, 120V/220V Universal |  
            | Interfaces I/O | GPIB, Other, RS-232 |  
            | Product Weight | 4.5 LBS |  
            | Product Height | 208 MM (8.19 IN) |  
            | Product Length | 102 MM (4.02 IN) |  
            | Product Width | 191 MM (7.52 IN) |  
            | ECCN Number | EAR99 |  
            | Country of Origin | United States |    |  
					
                
        
        
              Cases
              Software