Amprobe AM-160-A
Catalog #: 3730036
1000V TRMS AC/DC Digital Multimeter with Optical PC Interface and Dual Temperature
- Overview
- Specifications
- Summary
Product Highlights
- True-rms
- Measurements: voltage up to 1000V AC/DC, resistance, AC/DC current, frequency, capacitance, duty cycle
- Optical isolated PC interface capability
- Crest (peak hold), max, min, max-min, recording
- Auto and manual ranging
- Intelligent auto power off
- Data hold
- Relative zero mode
- Audible and visual warning against improper plug-in
- DC loop current 4-20mA
- dBm reading with 20 selectable impedance values
- Backlight display
- Large, easy to read large LCD display
- High speed analog bar graph
- Diode test
- 4-20mA DC loop current
- Audible continuity
Each Unit Includes
- 1 - Battery (installed)
- 1 - users manual
- 1 - test leads
- 1 - type-K thermocouple
Display |
4-4/5 digits 50,000 counts. Selectable stable mode 5-4/5 digits 500,000 counts for DC voltage, & 6 digits 999,999 counts for HZ |
Polarity |
Automatic |
Update Rate |
4-4/5 digits fast mode: 5 per second nominal;
5-4/5 digits stable mode: 1.25 Per second nominal; |
42 Segments Bar Graph |
60 per second max |
Operating Temperature |
0°C to 45°C (32°F to 113°F) |
Relative Humidity |
Maximum relative humidity 80% for temperature up to 31°C decreasing linearly to 50% relative humidity at 45°C |
Pollution Degree |
2 |
Storage Temperature |
-20°C to 60°C (-4°F to 140°F), < 80% R.H.(With battery removed) |
Altitude |
Operating below 2000m |
Temperature Coefficient |
Nominal 0.1 X (specified accuracy)/ °C @ (0°C -18°C or 28°C -- 0°C/32°F- 104°F), or otherwise specified |
Sensing |
AC, AC+DC true RMS |
Safety |
Double insulation per iec61010-1 2nd ed.,En61010-1 2nd ed., Ul61010-1 2nd ed.
& Can/csa c22.2 No. 61010.1-0.92 To category III 1000v AC & DC and category IV 600V AC & DC |
Am-160-a Terminals (to COM)
Measurement Category |
V / A / mAµA |
Category III 1000 VAC & VDC and category IV 600 VAC & VDC. |
Overload Protections |
µA & mA |
0.44A/1000V, IR 10kA or better, F fuse |
A |
11A/1000V, IR 20kA or better, F fuse |
V, mV, e, & others |
1050VRMS, 1450VPEAK |
Transient Protection |
8kV (1.2/50µS SURGE) |
E.M.C. |
Meets en61326-1:2006 (EN55022, EN61000-3-2, EN61000-3-3, EN61000- 4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4- 8, EN61000-4-11) |
In an RF field of 3V/m |
Capacitance function is not specified |
Other Function Ranges |
Total accuracy = specified accuracy + 100 digits.
Performance above 3V/m is not specified |
Power Supply |
Single alkaline 9V battery; neda1604a, jis6am6 or Iec6lf22 |
Power Consumption |
6mA typical |
Low Battery |
Below approx. 7V |
Apo Timing |
Idle for 17 minutes |
Apo Consumption |
5µA typical for am-140-a; 30µA typical for am-160-a |
Dimension |
L317.6 x W177.8 x H76.2 mm (12.5 x 7 x 3in) with clamshell |
Weight |
635g (1.4lb) with clamshell |
ELECTRICAL SPECIFICATIONS |
|
Range |
Accuracy |
AC Voltage |
500.00 mV
5.0000 / 50.000 / 500.00 / 1000.0 V |
+/-(0.08% Rdg + 20 LSD) @ 45 to 300 Hz** |
DC Voltage |
500.00 mV
5.0000 / 50.000 / 500.00 / 1000.0 V |
+/-(0.02% Rdg + 2 LSD) @ 0 to 50V** |
Resistance |
500.00 Ohms
5.0000 / 50.000 / 500.00 kOhms
5.0000 / 50.00 0MOhms |
+/-(0.07% Rdg + 2 LSD)
@ 500 Ohms to 500 kOhms ranges ** |
AC Current |
500.00 / 5000.0 uA
50.000 / 500.00 mA
5.0000 / 10.000 A |
+/-(0.5% Rdg + 50 LSD) @ 50 and 60 Hz** |
DC Current |
500.00 / 5000.0 uA
50.000 / 500.00 mA
5.0000 / 10.000 A |
+/-(0.5% Rdg + 20 LSD) |
Frequency |
5.0000 Hz to 200.000kHz |
+/-(0.002% Rdg + 4 LSD) |
Capacitance |
50.00 / 500.0 nF
5.000 / 50.00 / 500.0 / 9999uF |
+/-(2.0% Rdg + 3 LSD)
@ 50 nF to 50uF ranges** |
Temperature |
Dual thermocouple
-58 F to 1832 F
-50 C to 1000 C |
+/-(0.3% Rdg + 2 F)
+/-(0.3% Rdg + 1 C) |
Duty Cycle |
0.1% to 99.99% |
+/-(3 LSD / kHz + 3 LSD) |
|
DIODE TESTER |
Range |
5.0000V |
Accuracy |
1%+1D |
Test Current (Typical) |
0.4mA |
Open Circuit Voltage |
<3.5VDC |
Multimeters Template |
Type |
Digital |
Style |
Hand-Held |
Measures AC V |
Yes |
Measures DC V |
Yes |
Measures AC A |
Yes |
Measures DC A |
Yes |
True RMS |
Yes |
Maximum Voltage AC |
1000 V |
Maximum Voltage DC |
1000 V |
Maximum Current AC |
10 A |
Maximum Current DC |
10 A |
Basic Accuracy V DC |
± 0.05% Rdg + 2D |
# Digit Display |
5.5 |
Counts |
500000 . |
Backlight |
Yes |
Manual/Autoranging |
Both |
Dual Display |
No |
Analog Bargraph on Display |
Yes |
Decibels |
No |
Resistance |
Yes |
Frequency |
Yes |
Continuity |
Yes |
Capacitance |
Yes |
Temperature |
Yes |
Diode Testing |
Yes |
CAT Rating |
III |
CAT Voltage |
1,000 V |
IS |
No |
Peak Hold |
Yes |
Overload Protector |
Yes |
Kelvin 4-Wire Measurement Capability |
No |
Wireless Display |
No |
Data Hold |
Yes |
Low-Pass Filter |
No |
Duty Cycle % |
0.1% to 99.99% |
Unique Features |
Optical Isolated PC Interface Capability, Relative Zero Mode, Audible and Visual Warning against Improper Plug-in, DC Loop Current 4-20mA, dBm Reading with 20 Selectable Impedance Values |
Warranty |
1 YEARS |
Warranty Details |
1 Year from the Date of Purchase, This Warranty Does Not Cover Fuses, Disposable Batteries or Damage from Accident, Neglect, Misuse, Alteration, Contamination or Abnormal Conditions of Operation or Handling |
Additional Info/Comments |
PC Interface Kit, Software, Carrying Case, Users Manual |
Safety Approval |
CSA |
Product Weight |
1.4 LBS |
Product Height |
3 IN |
Product Length |
12.5 IN |
Product Width |
7 IN |
Data Logging |
No |
HTS/Schedule B Number |
9030.31.0000 |
ECCN Number |
EAR99 |
Calibration Included |
Factory Calibration |
Power Supply Voltage |
Battery Powered |
Country of Origin |
Taiwan |
Shipping Height |
3.25 IN |
Shipping Length |
12.50 IN |
Shipping Width |
7.00 IN |
|