Amprobe ACD-41PQ
Catalog #: 2730760
600V/1000A TRMS AC Power Quality Clamp Meter with Temperature, THD & Accessories
- Overview
- Specifications
- Summary
Product Highlights
- True-rms sensing measures active (W), reactive (VAR) and apparent (VA) power with dual-display power factor readout
- Total harmonics distortion (THD), AC/DC voltage up to 600V, AC current up to 1000A, resistance, frequency, temperature
- Peak hold
- Optional PC interface capability (RS-232 KIT2)
- Audible continuity
- Auto power off
- Automatic polarity
- Low battery indication
- Data hold
- Large, easy to read LCD display with backlight
- Accommodates conductors up to 1.77 (45mm) in diameter
- Carrying case, test leads, batteries (installed), thermocouple and manual included
- Voltage overload protection for all functions up to 600V AC/DC
Each Unit Includes
- 1 - Carrying case
- 1 - test leads
- 1 - batteries (installed)
- 1 - Thermocouple
TRMS |
YES |
AC Current |
40.0 / 400.0 / 1000 A |
AC Current Basic Accuracy |
+/-(1.0% Rdg + 5 LSD) @ 50 and 60Hz |
DC Voltage |
600.0V |
DC Voltage Basic Accuracy |
+/-(0.5% Rdg + 5 LSD) |
AC Voltage |
600.0V |
AC Voltage Basic Accuracy |
+/-(1.0% Rdg + 5 LSD) @ 50 / 60 |
Resistance |
999.9 Ohms |
Resistance Basic Accuracy |
+/-(1.0% Rdg + 6 LSD) |
Frequency |
5.00Hz to 500.0Hz |
Frequency Basic Accuracy |
+/-(0.5% Rdg +4 LSD) |
THD-R |
0.0% to 99.9% |
THD-R Basic Accuracy |
1.5% of Reading + 6d @ Fund Frequency |
Temperature |
-58 F to 572 (-50 C to 300 C) |
Temperature Basic Accuracy |
+/-(2.0% Rdg + 6F) +/-(2.0 % Rdg + 3C) |
Hi-Lo Logging |
5400 Points |
Clamp Meters/Clamp Meters Template |
Type |
Power Clamp Meter |
True RMS |
Yes |
Maximum Current AC |
1000 A |
Maximum Voltage AC |
600 V |
Maximum Voltage DC |
600 V |
Basic Voltage Accuracy |
ACV: ± 2.5% Rdg + 5D; DCV: ± 0.5% Rdg + 5D |
Counts |
9999 . |
Maximum Conductor Size |
1.77 IN |
Auto Ranging/Manual |
Auto Ranging |
Auto Power Off |
Yes |
Detachable Jaw |
No |
Rotating Jaw / Swivel |
No |
Peak Hold |
Yes |
Min/Max |
No |
In-Rush Current |
No |
Dual Display |
Yes |
Analog Bargraph on Display |
No |
Backlight |
Yes |
Remote Display |
No |
Resistance |
Yes |
Frequency |
Yes |
Continuity |
Yes |
Capacitance |
No |
Temperature (K T/C) |
Yes |
Temperature (IR Sensor) |
No |
Diode Testing |
No |
CAT Rating |
III |
Overload Protector |
Yes |
True Power (KW) |
No |
Max True Power (KW) |
600 kW |
Apparant power (VA) |
Yes |
Power Factor (PF) |
Yes |
Crest Factor |
Yes |
Energy (KWh) |
No |
Reactive Power (KVAR) |
Yes |
Source/Simulate (Process Clamp) |
No |
Unique Features |
Automatic Polarity, Low Battery Indication, Total Harmonic Distortion to 51st Harmonic |
Interfaces I/O |
RS-232 |
Product Weight |
224 GRAMS (0.494 LBS) |
Product Height |
1.6 IN |
Product Length |
8.9 IN |
Product Width |
3.1 IN |
Data Logging |
No |
Battery Type |
AAA |
Power Supply Voltage |
Battery Powered |
Country of Origin |
Taiwan |
Shipping Height |
3.50 IN |
Shipping Length |
12.25 IN |
Shipping Width |
7.25 IN |
Other Information |
TRMS: YES
AC Current: 40.0 / 400.0 / 1000 A
AC Current Basic Accuracy: +/-(1.0% Rdg + 5 LSD) @ 50 and 60Hz
DC Voltage: 600.0V
DC Voltage Basic Accuracy: +/-(0.5% Rdg + 5 LSD)
AC Voltage: 600.0V
AC Voltage Basic Accuracy: +/-(1.0% Rdg + 5 LSD) @ 50 / 60
Resistance: 999.9 Ohms
Resistance Basic Accuracy: +/-(1.0% Rdg + 6 LSD)
Frequency: 5.00Hz to 500.0Hz
Frequency Basic Accuracy: +/-(0.5% Rdg +4 LSD)
THD-R: 0.0% to 99.9%
THD-R Basic Accuracy: 1.5% of Reading + 6d @ Fund Frequency
Temperature: -58 F to 572 (-50 C to 300 C)
Temperature Basic Accuracy: +/-(2.0% Rdg + 6F) +/-(2.0 % Rdg + 3C)
Hi-Lo Logging: 5400 Points
|
|
|
|
|